Tripp Lite SMX3000XLRT2UA SmartPro 3000VA 3000W 208/230V Line-Interactive Sine Wave UPS - 10 Outlets Extended Run Network Card Option LCD USB DB9 2U Rack/Tower
$1,642.90
Manufacturer:Eaton / Tripp Lite
Model:SMX3000XLRT2UA
Condition:New
Availability:In Stock
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SMX Series
- UPS Battery Backup
- Tripp Lite SMX3000XLRT2UA SmartPro 3000VA 3000W 208/230V Line-Interactive Sine Wave UPS - 10 Outlets Extended Run Network Card Option LCD USB DB9 2U Rack/Tower
Datasheet
The Tripp Lite SMX3000XLRT2UA SmartPro 3kVA/2700W Line-Interactive UPS system offers reliable battery backup and surge protection for critical server network and telecommunications equipment. With a sine wave output it ensures compatibility with sensitive electronics. The 2U rack/tower convertible design allows for flexible installation in various environments.
This UPS features an LCD interface for status monitoring USB and RS232 communication ports and an Emergency Power Off (EPO) port. It supports optional extended run time batteries and the SNMPWEBCARD for network management. This 230V model provides robust power protection for international applications.
| APPLICATIONS | |
| UPS Applications | Large Network; High-End Desktop/Small Network |
| COMMUNICATIONS | |
| Communications Cable | USB and DB9 cabling included |
| Communications Interface | Contact closure; DB9 Serial; Slot for SNMP/Web interface; USB (HID enabled) |
| Emergency Power Off (EPO)/Remote On-Off (ROO) | Yes |
| Network Management Card Description | Optional WEBCARDLXE only (Sold separately). Not compatible with WEBCARDLX. |
| Network Monitoring Port Description | Network Card Optional. Not compatible with WEBCARDLX. |
| Network UPS Tools (NUT) Compatibility | NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert Office software at https://tripplite.eaton.com/poweralert |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMX3000XLRT2UA |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks; Schedulable daily hours of economy mode operation |
| Grounding Details | Rear panel grounding lug |
| High Availability UPS Features | Automatic Voltage Regulation (AVR); Expandable battery backup; Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 294 |
| Low Voltage Transfer to Battery Power (Setpoint) | 160 |
| Transfer Time | 1-4ms for normal mode >5ms for sensitive mode |
| OVERVIEW | |
| UPC Code | 037332181381 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CAN/CSA-C22.2 No. 107.3 (Canada); CSA (Canada); ICES (Canada); NOM (Mexico); UL 1778 |
| Product Compliance | CE (Europe); ENERGY STAR Qualified; FCC Part 15 Class A (USA); RoHS |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| UPS AC Suppression Joule Rating | 175 |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and perform the applicable action to resolve the condition. If the alarm status changes the alarm beeps again overriding the previous alarm silencing |
| Audible Alarm | Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions |
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
| Switches | 5 pushbutton switches control OFF / ON power status ENTER UP and DOWN selection and ESC control functions |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Reduces incoming voltage between 265-294V (Normal Mode / Extended Mode) by 13% |
| Severe Undervoltage Correction | UPS: 3 status-indicating LEDs (normal battery mode alarm/fault); LED colors (green = ON orange = On battery flashing orange = below warning level red = alarm/fault). |
| Undervoltage Correction | Increases incoming voltage between 162-184V (Normal Mode) or 151-184V (Extended Mode) by 15% |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 150 to 294 |
| Battery | |
| Battery Access | Front panel battery access door |
| Battery Recharge Rate (Included Batteries) | Less than 5 hours from 10 to 90% (typical full load discharge) |
| Battery Replacement Description | Hot-swappable replaceable batteries |
| DC System Voltage (VDC) | 72 |
| Expandable Runtime | Yes |
| Runtime Full Load (min.) | 3 min. (3000W) |
| Runtime Half Load (min.) | 9 min. (1500W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 208 |
| AC Mode Efficiency Rating (100% Load) | >96% |
| Audible Noise | 50 dBA maximum front side 1m |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 20 to 95% non-condensing |
| Storage Elevation (ft.) | 0-32808 |
| Storage Elevation (m) | 0-10000 |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Operating Elevation | 0-10000 |
| Input | |
| Input Phase | Single-Phase |
| Nominal Input Voltage(s) Supported | 200V AC; 208V AC; 220V AC; 230V AC; 240V AC |
| Rated input current (Maximum Load) | 16A |
| UPS Input Connection Description | IEC320-C20 input connection accepts included IEC C19 to L6-20P 6ft (1.8m) included input cordset. Also supports user supplied detachable C19 output cordsets to match country or site-specific power source connections. |
| UPS Input Connection Type | C20 inlet |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Automatic frequency selection |
| Included Output Power Cables | Set of 2x 6ft. C13 to C14 power cables included. |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | Two switchable load banks: Load 1 (2x C13; C19) Load 2 (2x C13) |
| Nominal Output Voltage(s) Supported | 200V; 208V; 220V; 230V; 240V |
| Nominal Voltage Details | 208v nominal inverter output voltage |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 3 |
| Output Capacity (kW) | 3 |
| Output Capacity (VA) | 3000 |
| Output Capacity (Watts) | 3000 |
| Output Receptacles | (8) C13; (2) C19 |
| Output Voltage Regulation (Battery Mode) | -10% +6% |
| Output Voltage Regulation (Line Mode) | 208V (-13% +15%) |
| Power Factor | 1.0 |
| Physical | |
| Cooling Method | Fan |
| Included Mounting Accessory Description | Included 4-post mounting kit enables installation in 4 post racks. Two ABS mounting stands enables the UPS to be configured in an upright tower orientation. |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount; Tower |
| Minimum Required Rack Depth (cm) | 68.58 |
| Minimum Required Rack Depth (inches) | 27 |
| Minimum Required Rack Depth with External Battery Pack (cm) | 69 |
| Minimum Required Rack Depth with External Battery Pack (in.) | 27 |
| Minimum Required Rack Depth without External Battery Pack (cm) | 69 |
| Minimum Required Rack Depth without External Battery Pack (in.) | 27 |
| Primary Form Factor | Rackmount; Tower |
| Primary UPS Depth (mm) | 602 |
| Primary UPS Height (mm) | 86 |
| Primary UPS Width (mm) | 437 |
| Shipping Dimensions (hwd / cm) | 23.88 x 57.91 x 78.49 |
| Shipping Dimensions (hwd / in.) | 9.40 x 22.80 x 30.90 |
| Unit Dimensions (hwd / in.) | 3.400 x 17.200 x 23.700 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd cm) | 8.64 x 43.69 x 60.20 |
| UPS Power Module Dimensions (hwd in.) | 3.4 x 17.2 x 23.7 |
| UPS Power Module Weight (kg) | 31.71 |
| UPS Power Module Weight (lbs.) | 69.9 |
| Rack Height | 2U |
| Shipping Weight (kg) | 38.51 |
| Shipping Weight (lbs.) | 84.90 |
| Warranty | |
| Warranty/Returns | 30 Days |