Tripp Lite SMART750RMXL2UN SmartPro 750VA 750W 120V Line-Interactive Sine Wave UPS - 8 Outlets Extended Run Network Card Included LCD USB DB9 2U Rack/Tower
$1,058.84
Manufacturer:Eaton / Tripp Lite
Model:SMART750RMXL2UN
Condition:New
Availability:Out Of Stock
Condition:New
Availability:Out Of Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SMART Series
- UPS Battery Backup
- Tripp Lite SMART750RMXL2UN SmartPro 750VA 750W 120V Line-Interactive Sine Wave UPS - 8 Outlets Extended Run Network Card Included LCD USB DB9 2U Rack/Tower
Datasheet
The Tripp Lite SMART750RMXL2UN SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS is a 2U rack/tower mountable unit ideal for protecting critical servers networking equipment and telecom installations. It offers reliable battery backup with sine wave output extended runtime capabilities via optional external battery packs and advanced features like automatic voltage regulation (AVR).
Equipped with a user-friendly LCD interface USB and DB9 communication ports and network management capabilities via the optional WEBCARDLX the SMART750RMXL2UN offers comprehensive power protection and monitoring. It ensures business continuity during power outages and safeguards sensitive equipment from damaging surges and voltage fluctuations.
| APPLICATIONS | |
| UPS Applications | High-End Desktop/Small Network; Audio/Video; Home Network; Smart Home |
| COMMUNICATIONS | |
| Communications Cable | Micro-USB USB and DB9 cabling included |
| Communications Interface | DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface; USB (HID enabled) |
| Network Compatibility | 10 Mbps; 100 Mbps (Fast Ethernet) |
| Network Management Card Description | Network management card included |
| Network Monitoring Port | RJ45 Network port Micro-USB Configuration/Console port USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. |
| Network Monitoring Port Description | Pre-installed WEBCARDLXE supports detailed monitoring and management of UPS and site power conditions. Not compatible with WEBCARDLX |
| Network UPS Tools (NUT) Compatibility | NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert Office software at https://tripplite.eaton.com/products/power-alert |
| SNMP Compatibility | SNMP V1 V2c V3 |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMART750RMXL2UN |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Grounding Details | Rear panel grounding lug |
| High Availability UPS Features | Auto Probe Monitoring and Reboot (included); Automatic Voltage Regulation (AVR); Expandable battery backup; Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 151 |
| Low Voltage Transfer to Battery Power (Setpoint) | 83 |
| Transfer Time | 4 milliseconds (AC to battery mode) 2 milliseconds (Battery to AC mode) |
| OVERVIEW | |
| UPC Code | 037332256409 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CAN/CSA-C22.2 No. 107.3 (Canada); CSA (Canada); ICES (Canada); NOM (Mexico); UL 1778 |
| Product Compliance | CE (Europe); FCC Part 15 Class A (USA); RoHS |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 380 |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
| Audible Alarm | Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions |
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
| LED Indicators | UPS: 3 status-indicating LEDs (normal battery mode alarm/fault); LED colors (green = ON orange = On battery flashing orange = below warning level red = alarm/fault). LX Platform Interface Status: Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing) 100 Mbps (On steady). Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec). |
| Switches | 5 pushbutton switches control OFF / ON power status ENTER UP and DOWN selection and ESC control functions. LX Platform Interface: Recessed reset switch for interface reboot and factory reset |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Reduces incoming voltage between 132-151V by 13% (Normal Mode); 138-152V (Extended mode) |
| Undervoltage Correction | Boost incoming voltages between 81-102V by 15% (Normal Mode); 71-92V by 15% (Extended Mode) |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 150V (Normal mode) adjustable to 70-153V (Extended mode) |
| Battery | |
| Battery Access | Front panel battery access door |
| Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% (typical full load discharge) |
| Battery Replacement Description | 48V DC Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 48 |
| Expandable Runtime | Yes |
| Runtime Full Load (min.) | 8.5 min. (750W) |
| Runtime Half Load (min.) | 20.7 min. (375W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 70 |
| AC Mode Efficiency Rating (100% Load) | 95% |
| Audible Noise | 45 dBA maximum front side 1m |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 465 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Elevation (ft.) | 0-32808 |
| Storage Elevation (m) | 0-10000 |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Operating Elevation | 0-10000 ft. (0-3000 m) |
| Input | |
| Input Phase | Single-Phase |
| Maximum Input Amps | 8 |
| Nominal Input Voltage Description | 80V-151V; adjustable to 70-153V |
| Nominal Input Voltage(s) Supported | 120V AC |
| Rated input current (Maximum Load) | 7.5A |
| Recommended Electrical Service | 15A 120V |
| UPS Input Connection Type | 5-15P |
| UPS Input Cord Length (ft.) | 6 |
| UPS Input Cord Length (m) | 1.8 |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | Two switchable two-outlet 5-15R load banks |
| Nominal Output Voltage(s) Supported | 110V; 115V; 120V |
| Nominal Voltage Details | 120v nominal output in battery mode |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 0.75 |
| Output Capacity (kW) | 0.75 |
| Output Capacity (VA) | 750 |
| Output Capacity (Watts) | 750 |
| Output Receptacles | (8) 5-15R |
| Output Voltage Regulation (Battery Mode) | -10% +6% |
| Output Voltage Regulation (Line Mode) | 120V (-13% +15%) |
| Power Factor | 1 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount |
| Minimum Required Rack Depth (cm) | 41.15 |
| Minimum Required Rack Depth (inches) | 16.2 |
| Minimum Required Rack Depth with External Battery Pack (cm) | 51 |
| Minimum Required Rack Depth with External Battery Pack (in.) | 20 |
| Minimum Required Rack Depth without External Battery Pack (cm) | 53 |
| Minimum Required Rack Depth without External Battery Pack (in.) | 21 |
| Mounting Details | Included 4-post mounting brackets that enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm). The tower stands are included to support tower orientation. |
| Primary Form Factor | Rackmount |
| Primary UPS Depth (mm) | 334 |
| Primary UPS Height (mm) | 88 |
| Primary UPS Width (mm) | 441 |
| Shipping Dimensions (hwd / in.) | 8.70 x 18.60 x 23.30 |
| Unit Dimensions (hwd / in.) | 3.450 x 17.200 x 17.600 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd in.) | 3.45 x 17.35 x 13.15 |
| UPS Power Module Weight (kg) | 16.06 |
| UPS Power Module Weight (lbs.) | 35.4 |
| Rack Height | 2U |
| Shipping Weight (kg) | 20.64 |
| Warranty | |
| Warranty/Returns | 30 Days |