Tripp Lite SMART3000RM2UN SmartPro 3000VA 3000W 120V Line-Interactive Sine Wave UPS - 7 Outlets Network Card Included LCD USB DB9 2U Rack/Tower
$1,839.49
Manufacturer:Eaton / Tripp Lite
Model:SMART3000RM2UN
Condition:New
Availability:In Stock
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SMART Series
- UPS Battery Backup
- Tripp Lite SMART3000RM2UN SmartPro 3000VA 3000W 120V Line-Interactive Sine Wave UPS - 7 Outlets Network Card Included LCD USB DB9 2U Rack/Tower
Datasheet
The Tripp Lite SMART3000RM2UN is a 3kVA 2.25kW line-interactive sine wave UPS system designed for critical IT equipment. It provides reliable battery backup and surge protection with automatic voltage regulation (AVR) to correct brownouts and overvoltages without using battery power. The included WEBCARDLX network interface card enables remote monitoring and control.
This versatile 2U rack/tower unit features a user-friendly LCD display USB and DB9 serial ports for connectivity and offers advanced features like auto-restart after power loss. The SMART3000RM2UN ensures business continuity and protects valuable equipment from damaging power fluctuations.
| APPLICATIONS | |
| UPS Applications | High-End Desktop/Small Network; Large Network |
| COMMUNICATIONS | |
| Communications Cable | Micro-USB USB and DB9 cabling included |
| Communications Interface | DB9 Serial; EPO (emergency power off); Micro-USB; Pre-installed network card; RJ45 Network; Slot for SNMP/Web interface; USB (HID enabled); USB-A |
| Emergency Power Off (EPO)/Remote On-Off (ROO) | Yes |
| EPO Port | RJ11 interface jack with 4-meter cable included. Supports normally open and normally closed EPO systems |
| Network Compatibility | 10 Mbps; 100 Mbps (Fast Ethernet) |
| Network Management Card Description | Network management card included |
| Network Monitoring Port | RJ45 Network port Micro-USB Configuration/Console port USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. |
| Network Monitoring Port Description | Includes pre-installed WEBCARDLXE Network Management Card interface. Not compatible with WEBCARDLX. |
| Network UPS Tools (NUT) Compatibility | NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite |
| PowerAlert Software | For local monitoring via the UPSs built-in Serial or USB communication ports download PowerAlert Home software at https://www.tripplite.com/poweralert. LX Platform Interface: PowerAlert Device Manager 20 (PADM20) |
| SNMP Compatibility | SNMP V1 V2c V3 |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMART3000RM2UN |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
| Grounding Details | Rear panel grounding lug |
| High Availability UPS Features | Auto Probe Monitoring and Reboot (included); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 151 |
| Low Voltage Transfer to Battery Power (Setpoint) | 80 |
| Transfer Time | 1-4ms for normal mode >5ms for sensitive mode |
| OVERVIEW | |
| UPC Code | 037332177902 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); ICES (Canada); NOM (Mexico); UL 1778 |
| Product Compliance | ENERGY STAR Qualified; FCC Part 15 Class A (USA); REACH; RoHS |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 380 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and perform the applicable action to resolve the condition. If the alarm status changes the alarm beeps again overriding the previous alarm silencing |
| Audible Alarm | Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions |
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
| LED Indicators | Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing) 100 Mbps (On steady). LXE Platform Interface Status: Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec). |
| Switches | 5 pushbutton switches control OFF / ON power status ENTER UP and DOWN selection and ESC control functions. LX Platform Interface: Recessed reset switch for interface reboot and factory reset |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Reduces incoming voltage between 132-151V by 13% (Normal Mode); 138-152V (Extended mode) |
| Undervoltage Correction | Boost incoming voltages between 81-102V by 15% (Normal Mode); 71-92V by 15% (Extended Mode) |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 150V (Normal mode) adjustable to 70-153V (Extended mode) |
| Battery | |
| Battery Access | Front panel battery access door |
| Battery Recharge Rate (Included Batteries) | Less than 5 hours from 10 to 90% (typical full load discharge) |
| Battery Replacement Description | Hot-swappable user replaceable 72VDC internal battery cartridge |
| DC System Voltage (VDC) | 72 |
| Expandable Runtime | No |
| Runtime Full Load (min.) | 3 min. (3000W) |
| Runtime Half Load (min.) | 9 min. (1500W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 173 |
| AC Mode Efficiency Rating (100% Load) | 96% |
| Audible Noise | 50 dBA maximum front side 1m |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 944 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Elevation (ft.) | 0-32808 |
| Storage Elevation (m) | 0-10000 |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Operating Elevation | 0-10000 ft. (0-3000 m) |
| Input | |
| Input Phase | Single-Phase |
| Maximum Input Amps | 24 |
| Nominal Input Voltage Description | 80V-151V; adjustable to 70-153V |
| Nominal Input Voltage(s) Supported | 120V AC |
| Rated input current (Maximum Load) | 24A (120V) |
| Recommended Electrical Service | 30A 120V |
| UPS Input Connection Type | L5-30P |
| UPS Input Cord Length (ft.) | 10 |
| UPS Input Cord Length (m) | 3.1 |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | Two switchable two-outlet load banks |
| Nominal Output Voltage(s) Supported | 110V; 115V; 120V |
| Nominal Voltage Details | 120v nominal output in battery mode |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 3 |
| Output Capacity (kW) | 3 |
| Output Capacity (VA) | 3000 |
| Output Capacity (Watts) | 3000 |
| Output Circuit Breakers | Three 20A output breakers protect 2x 5-20R outlets each |
| Output Receptacles | (6) 5-15/20R; (1) L5-30R |
| Output Voltage Regulation (Battery Mode) | -10% +6% |
| Output Voltage Regulation (Line Mode) | 120V (-13% +15%) |
| Power Factor | 1 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount; Tower |
| Minimum Required Rack Depth (cm) | 69.85 |
| Minimum Required Rack Depth (inches) | 27.5 |
| Mounting Details | Included mounting bracket enables installation in 4 post racks. Two ABS mounting stands enables the UPS to be configured in an upright tower orientation. |
| Primary Form Factor | Rackmount |
| Primary UPS Depth (mm) | 602 |
| Primary UPS Height (mm) | 86 |
| Primary UPS Width (mm) | 437 |
| Shipping Dimensions (hwd / cm) | 24.00 x 58.00 x 78.40 |
| Shipping Dimensions (hwd / in.) | 9.44 x 22.83 x 30.86 |
| Unit Dimensions (hwd / in.) | 3.400 x 17.200 x 23.700 |
| Unit Weight (kg) | 33.80 |
| Unit Weight (lbs.) | 74.516 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd cm) | 8.64 x 43.69 x 60.20 |
| UPS Power Module Dimensions (hwd in.) | 3.4 x 17.2 x 23.7 |
| UPS Power Module Weight (kg) | 33.80 |
| UPS Power Module Weight (lbs.) | 74.516 |
| Rack Height | 2U |
| Shipping Weight (kg) | 39.80 |
| Shipping Weight (lbs.) | 87.74 |
| Warranty | |