Datasheet
The Tripp Lite SMART1500RT1U is a 1500VA/1100W line-interactive UPS system designed to protect sensitive electronics from power outages and fluctuations. It provides five NEMA 5-15R outlets automatic voltage regulation (AVR) and both USB and DB9 communication ports for monitoring and control.
This versatile 1U UPS can be installed in a rack or tower configuration making it ideal for a variety of applications. Its compact design and comprehensive features offer reliable power protection for servers workstations and other critical equipment.
| APPLICATIONS | |
| UPS Applications | High-End Desktop/Small Network; Retail/Point of Sale; Hospitality |
| COMMUNICATIONS | |
| Communications Cable | USB and DB9 cabling included EPO/ROO jack for Emergency and Remote Shutdown. |
| Communications Interface | (1) EPO (emergency power off); (1) RS-232; (1) USB (HID enabled) |
| Emergency Power Off (EPO)/Remote On-Off (ROO) | Phoenix-style connection supports Emergency Power Off and Remote ON/OFF functions. |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMART1500RT1U |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Grounding Details | Back panel grounding lug |
| High Availability UPS Features | Auto Probe Monitoring (requires WEBCARDLXE); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 162 VAC (120VAC/127VAC INPUT) 139 VAC (100VAC INPUT) +/- 5% |
| Low Voltage Transfer to Battery Power (Setpoint) | 100V: 80VAC +/- 5% (HI sensitivity) 70VAC +/- 5% (LO sensitivity) @120V: 89VAC +/- 5% (HI sensitivity) 70VAC+/- 5% (LO sensitivity) @127V: 93VAC+/- 5% (HI sensitivity) 70VAC+/- 5% (LO sensitivity) |
| Transfer Time | 6-8 ms typical ( < 10 ms max) |
| OVERVIEW | |
| UPC Code | 037332239341 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); UL 1778 |
| Product Compliance | ENERGY STAR Qualified; FCC Part 15 Class B (USA) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 540 |
| AC Suppression Response Time | Instantaneous |
| USER INTERFACE ALERTS & CONTROLS | |
| Audible Alarm | Audible alarm indicates power ON power-failure warnings and low-battery conditions |
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage frequency operating mode alarm function and a variety of additional options (see manual) |
| LED Indicators | 2 LEDs indicate AC output status (Green); UPS fault (Solid Red)/ UPS abnormal conditions (Flashing Red). |
| Switches | ON button controls UPS ON Cold-start Self-test and menu functions. OFF button controls unit off fault clearance and menu functions. Alarm/Enter button control audible alarm state and menu confirmation. |
| VOLTAGE REGULATION | |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 90 (5%). Input voltage range of 90 to 139 |
| Battery | |
| Battery Access | Battery access panel |
| Battery Recharge Rate (Included Batteries) | 6 Hours to 90% |
| Battery Replacement Description | Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 36 |
| Expandable Runtime | No |
| Runtime Full Load (min.) | 2 min. (1100W) |
| Runtime Half Load (min.) | 8 min. (550W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Economy Mode Efficiency Rating (100% Load) | 0.98 |
| AC Mode BTU / Hr. (Full Load) | 48 |
| AC Mode Efficiency Rating (100% Load) | 98% |
| Audible Noise | 40 dBA maximum front side 1m |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Operating Elevation | 0-3280 ft. (0-1000 m) |
| Input | |
| Input Circuit Breakers | 15A |
| Input Phase | Single-Phase |
| Maximum Input Amps | 12 |
| Nominal Input Voltage(s) Supported | 100V AC; 120V AC; 127V AC |
| Rated input current (Maximum Load) | 11.3A (100V); 12A (120V); 10.8A (127V) |
| Recommended Electrical Service | 15A 120V |
| UPS Input Connection Type | 5-15P |
| UPS Input Cord Length (ft.) | 6 |
| UPS Input Cord Length (m) | 1.8 |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | LOAD 1 (BANK OF 2 OUTLETS); LOAD 2 (BANK OF 3 OUTLETS) |
| Nominal Output Voltage(s) Supported | 120V |
| Nominal Voltage Details | 120V sinusoidal in line mode and 120V sinusoidal in battery mode |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 1.44 |
| Output Capacity (kW) | 1.1 |
| Output Capacity (VA) | 1440 |
| Output Capacity (Watts) | 1100 |
| Output Capacity Details | 1440 VA @ 120VAC and 127VAC 100VAC: 1080 VA |
| Output Receptacles | (5) 5-15R |
| Output Voltage Regulation (Battery Mode) | -10% +6% |
| Output Voltage Regulation (Line Mode) | For 100V: 90VAC +/-5% -115VAC +/- 5% (78VAC +/- 5% -115VAC +/- 5%(@70VAC Input)) For 120V: 102VAC +/-5% -139VAC +/- 5% (78VAC +/- 5% -139VAC +/- 5%(@70VAC Input)) For 127V: 108VAC +/- 5% -145VAC +/- 5% (78VAC +/-5% -145VAC +/- 5% (@70VAC Input)) |
| Power Factor | 0.76 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | 2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount; Tower |
| Maximum Device Depth (cm) | 55.37 |
| Maximum Device Depth (in.) | 21.8 |
| Maximum Device Depth (mm) | 554 |
| Minimum Required Rack Depth (cm) | 63.50 |
| Minimum Required Rack Depth (inches) | 25 |
| Mounting Details | Included mounting brackets provide front-rail installation in 2 or 4 post racks plus upright tower configurations |
| Primary Form Factor | Rackmount; Tower |
| Primary UPS Depth (mm) | 554 |
| Primary UPS Height (mm) | 44 |
| Primary UPS Width (mm) | 440 |
| Unit Dimensions (hwd / in.) | 1.730 x 17.320 x 21.810 |
| Unit Weight (kg) | 16.80 |
| Unit Weight (lbs.) | 37.037 |
| UPS Housing Material | Steel |
| UPS Power Module Weight (kg) | 16.80 |
| UPS Power Module Weight (lbs.) | 37.037 |
| Rack Height | 1U |
| Warranty | |
| Warranty/Returns | 30 Days |