The Tripp Lite IS1000HGDV Isolation Transformer is a critical component for ensuring power quality and safety in medical environments. This 1000W unit provides galvanic isolation protecting sensitive hospital equipment from electrical noise and potential ground faults. It supports dual voltage (115/230V) for international compatibility.

Featuring a C14 inlet and eight C13 outlets the IS1000HGDV offers ample connectivity for various devices. Its 60601-1 medical-grade compliance guarantees its suitability for demanding healthcare applications offering reliable performance and enhanced safety.

DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number IS1000HGDV
FEATURES & SPECIFICATIONS
Over Current Protection 2 x 10A @ 115V and 2 x 5A at 230V ( Both Fuses included with Product as Accesories)
OPERATION
System Type Selections Input Voltage equals Output Voltage OR 120V input equals 230V output OR 230V Input equals 120V output -(Selectable when installing Fuses) Input Frequency always equals Output Frequency
OVERVIEW
Efficiency 96%
Nominal Voltage / Frequency 115/230 VAC 50/60 HZ (Voltage Selected by Input Power Module Fuse Installation
Transformer Type Medical Grade Low Impedence Toroid- Line Isolation (Pass Through or Step UP or Step Down)
UPC Code 037332200020
VA / Watt Capacity 1000
STANDARDS & COMPLIANCE
Product Certifications IEC 60601-1; CAN/CSA-C22.2 No. 60601-1 (Canada); NOM (Mexico)
Product Compliance RoHS; CE (Europe)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 240
IEEE587 Cat. A Ringwave Let-Through Reduced to 0.5v Common Mode
Noise Suppression Rating 35-65 dB
Details
Category Isolation Transformers
Environmental
Operating Humidity Range 5% to 95% RH (Non-Condensing)
Operating Temperature Range 32 to 104F (0 to 40C) Intended Application is in a controlled environment at approx. 77F.
Storage Temperature Range 5 to 122F (-15 to 50C)
Operating Elevation 0-10000 ft. (0-3000 m)
Input
Maximum Surge Amps 70A
Nominal Input Voltage Description 115/230 VAC (Selected by Input Power Module Fuse Installation) Operating Input Voltage Range 100-125Vac or 200-250VAC
Power Input Receptacle IEC-320-C14
THDi Less than 1%
Input Current 10A @ 115V / 5A @ 230V
Input Frequency 50/60HZ
Isolation
Leakage Current Max AC Leakage Current 80 (uA)
Output Isolation Transformer Toroid with AC output Floating with Respect to Earth Ground. POAG Connector and Earth Ground Stud.
Output
Frequency Compatibility 50 / 60 Hz
Output (Watts) 1000
Output Amp Capacity 8.7@ 115V/ 4.3@230V
Output Nominal Voltage 115V/230V (Selected by Output Switch) Can also be step up or step down Selected when Installing Fuses.
Output Receptacles (8) C13
Physical
Cooling Method Convection
Shipping Dimensions (hwd / cm) 26.01 x 38.00 x 43.51
Shipping Dimensions (hwd / in.) 10.24 x 14.96 x 17.13
Unit Dimensions (hwd / cm) 1303 x 2499 x 3000
Unit Dimensions (hwd / in.) 5.130 x 9.840 x 11.810
Unit Weight (kg) 13.72
Unit Weight (lbs.) 30.25
Color White
Material Of Construction Metal (Cabinet)
Shipping Weight (kg) 14.66
Shipping Weight (lbs.) 32.32
Warranty
Warranty/Returns 30 Days