Tripp Lite IS300HGDV Isolator Series Dual-Voltage 115/230V 300W 60601-1 Medical-Grade Isolation Transformer C14 Inlet 4 C13 Outlets IS Series

Tripp Lite IS300HGDV Isolator Series Dual-Voltage 115/230V 300W 60601-1 Medical-Grade Isolation Transformer C14 Inlet 4 C13 Outlets

$687.91
Manufacturer:Eaton / Tripp Lite
Model:IS300HGDV
Condition:New
Availability:In Stock
The Tripp Lite IS300HGDV Isolation Transformer provides safe reliable power for medical equipment. This 300W unit features dual-voltage (115/230V) operation and four C13 outlets.
Datasheet

The Tripp Lite IS300HGDV Isolation Transformer is a medical-grade power solution designed to protect sensitive equipment in healthcare settings. With a 300W capacity and dual-voltage compatibility (115/230V) it adapts to various power requirements. The transformer's C14 inlet and four C13 outlets provide convenient connectivity for multiple devices.

This Isolator Series transformer meets 60601-1 medical safety standards ensuring reliable and isolated power delivery. It helps reduce electrical noise and protect against potential ground faults crucial for the safe operation of critical medical equipment.

DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number IS300HGDV
FEATURES & SPECIFICATIONS
Over Current Protection 2 x 3.15A @ 115V and 2 x 1.6A at 230V ( Both Fuses included with Product as Accesories)
OPERATION
System Type Selections Input Voltage equals Output Voltage OR 120V input equals 230V output OR 230V Input equals 120V output -(Selectable when installing Fuses) Input Frequency always equals Output Frequency
OVERVIEW
Nominal Voltage / Frequency 115/230 VAC 50/60 HZ (Voltage Selected by Input Power Module Fuse Installation
Transformer Type Medical Grade Low Impedence Toroid- Line Isolation (Pass Through or Step UP or Step Down)
UPC Code 037332199980
VA / Watt Capacity 300
STANDARDS & COMPLIANCE
Product Certifications IEC 60601-1; CAN/CSA-C22.2 No. 60601-1 (Canada); NOM (Mexico)
Product Compliance RoHS; CE (Europe)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 240
IEEE587 Cat. A Ringwave Let-Through Reduced to 0.5v Common Mode
Noise Suppression Rating 35-65 dB
Details
Category Isolation Transformers
Environmental
Operating Humidity Range 5% to 95% RH (Non-Condensing)
Operating Temperature Range 32 to 104F (0 to 40C) Intended Application is in a controlled environment at approx. 77F.
Storage Temperature Range 5 to 122F (-15 to 50C)
Operating Elevation 0-10000 ft. (0-3000 m)
Input
Maximum Surge Amps 70A
Nominal Input Voltage Description 115/230 VAC (Selected by Input Power Module Fuse Installation) Operating Input Voltage Range 100-125Vac or 200-250VAC
Power Input Receptacle IEC-320-C14
THDi Less than 1%
Input Current 3.15A @ 115V / 1.6A @ 230V
Input Frequency 50/60HZ
Isolation
Leakage Current Max AC Leakage Current 50 (uA)
Output Isolation Transformer Toroid with AC output Floating with Respect to Earth Ground. POAG and Earth Ground Studs.
Output
Frequency Compatibility 50 / 60 Hz
Outlet Details Qty 4 Receptacles
Output (Watts) 300
Output Nominal Voltage 115V/230V (Selected by Output Switch) Can also be step up or step down Selected when Installing Fuses.
Output Receptacles (4) C13
Output Voltage Regulation (Line Mode) 5.2%
Physical
Cooling Method Convection
Shipping Dimensions (hwd / cm) 21.01 x 24.99 x 32.51
Shipping Dimensions (hwd / in.) 8.27 x 9.84 x 12.80
Unit Dimensions (hwd / cm) 11 x 15 x 20
Unit Dimensions (hwd / in.) 4.330 x 5.910 x 7.870
Unit Weight (kg) 5.60
Unit Weight (lbs.) 12.35
Color White
Material Of Construction Metal (Cabinet)
Shipping Weight (kg) 6.18
Shipping Weight (lbs.) 13.62
Warranty
Warranty/Returns 30 Days