Tripp Lite IS1000HGDV Isolator Series Dual-Voltage 115/230V 1000W 60601-1 Medical-Grade Isolation Transformer C14 Inlet 8 C13 Outlets
$886.09
Manufacturer:Eaton / Tripp Lite
Model:IS1000HGDV
Condition:New
Availability:Out Of Stock
Condition:New
Availability:Out Of Stock
- Power Protection
- Eaton / Tripp Lite
- Isolation Transformers
- IS Series
- Tripp Lite IS1000HGDV Isolator Series Dual-Voltage 115/230V 1000W 60601-1 Medical-Grade Isolation Transformer C14 Inlet 8 C13 Outlets
Datasheet
The Tripp Lite IS1000HGDV Isolation Transformer is a critical component for ensuring power quality and safety in medical environments. This 1000W unit provides galvanic isolation protecting sensitive hospital equipment from electrical noise and potential ground faults. It supports dual voltage (115/230V) for international compatibility.
Featuring a C14 inlet and eight C13 outlets the IS1000HGDV offers ample connectivity for various devices. Its 60601-1 medical-grade compliance guarantees its suitability for demanding healthcare applications offering reliable performance and enhanced safety.
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | IS1000HGDV |
| FEATURES & SPECIFICATIONS | |
| Over Current Protection | 2 x 10A @ 115V and 2 x 5A at 230V ( Both Fuses included with Product as Accesories) |
| OPERATION | |
| System Type Selections | Input Voltage equals Output Voltage OR 120V input equals 230V output OR 230V Input equals 120V output -(Selectable when installing Fuses) Input Frequency always equals Output Frequency |
| OVERVIEW | |
| Efficiency | 96% |
| Nominal Voltage / Frequency | 115/230 VAC 50/60 HZ (Voltage Selected by Input Power Module Fuse Installation |
| Transformer Type | Medical Grade Low Impedence Toroid- Line Isolation (Pass Through or Step UP or Step Down) |
| UPC Code | 037332200020 |
| VA / Watt Capacity | 1000 |
| STANDARDS & COMPLIANCE | |
| Product Certifications | IEC 60601-1; CAN/CSA-C22.2 No. 60601-1 (Canada); NOM (Mexico) |
| Product Compliance | RoHS; CE (Europe) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 240 |
| IEEE587 Cat. A Ringwave Let-Through | Reduced to 0.5v Common Mode |
| Noise Suppression Rating | 35-65 dB |
| Details | |
| Category | Isolation Transformers |
| Environmental | |
| Operating Humidity Range | 5% to 95% RH (Non-Condensing) |
| Operating Temperature Range | 32 to 104F (0 to 40C) Intended Application is in a controlled environment at approx. 77F. |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Operating Elevation | 0-10000 ft. (0-3000 m) |
| Input | |
| Maximum Surge Amps | 70A |
| Nominal Input Voltage Description | 115/230 VAC (Selected by Input Power Module Fuse Installation) Operating Input Voltage Range 100-125Vac or 200-250VAC |
| Power Input Receptacle | IEC-320-C14 |
| THDi | Less than 1% |
| Input Current | 10A @ 115V / 5A @ 230V |
| Input Frequency | 50/60HZ |
| Isolation | |
| Leakage Current | Max AC Leakage Current 80 (uA) |
| Output Isolation Transformer | Toroid with AC output Floating with Respect to Earth Ground. POAG Connector and Earth Ground Stud. |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Output (Watts) | 1000 |
| Output Amp Capacity | 8.7@ 115V/ 4.3@230V |
| Output Nominal Voltage | 115V/230V (Selected by Output Switch) Can also be step up or step down Selected when Installing Fuses. |
| Output Receptacles | (8) C13 |
| Physical | |
| Cooling Method | Convection |
| Shipping Dimensions (hwd / cm) | 26.01 x 38.00 x 43.51 |
| Shipping Dimensions (hwd / in.) | 10.24 x 14.96 x 17.13 |
| Unit Dimensions (hwd / cm) | 1303 x 2499 x 3000 |
| Unit Dimensions (hwd / in.) | 5.130 x 9.840 x 11.810 |
| Unit Weight (kg) | 13.72 |
| Unit Weight (lbs.) | 30.25 |
| Color | White |
| Material Of Construction | Metal (Cabinet) |
| Shipping Weight (kg) | 14.66 |
| Shipping Weight (lbs.) | 32.32 |
| Warranty | |
| Warranty/Returns | 30 Days |