Tripp Lite SMART500RT1UTAA TAA-Compliant SmartPro 120V 500VA 300W Line-Interactive UPS 1U Rack/Vertical Network Card Options USB DB9 Serial
$268.01
Manufacturer:Eaton / Tripp Lite
Model:SMART500RT1UTAA
Condition:New
Availability:In Stock
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SMART Series
- UPS Battery Backup
- Search
- Tripp Lite SMART500RT1UTAA TAA-Compliant SmartPro 120V 500VA 300W Line-Interactive UPS 1U Rack/Vertical Network Card Options USB DB9 Serial
Datasheet
The Tripp Lite SMART500RT1UTAA 500VA UPS System is a smart rack-mountable solution designed to provide reliable battery backup and surge protection for connected equipment. Its automatic voltage regulation (AVR) feature corrects minor power fluctuations without switching to battery extending battery life. This 1U unit features a network card for remote management capabilities.
With 500VA/300W capacity and USB/DB9 connectivity the SMART500RT1UTAA safeguards servers networking devices and other sensitive electronics. The TAA compliance ensures it meets government procurement requirements making it ideal for federal agencies and contractors.
| APPLICATIONS | |
| UPS Applications | Large Network; High-End Desktop/Small Network |
| COMMUNICATIONS | |
| Communications Cable | USB and DB9 cabling included |
| Communications Interface | DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| Network UPS Tools (NUT) Compatibility | NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMART500RT1UTAA |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Grounding Details | Back panel grounding lug |
| High Availability UPS Features | Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 136 |
| Low Voltage Transfer to Battery Power (Setpoint) | 90 |
| Transfer Time | 2-4 milliseconds |
| OVERVIEW | |
| UPC Code | 037332204134 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); UL 1778 |
| Product Compliance | RoHS; FCC Part 15 Class B (USA); Trade Agreements Act (TAA) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 567 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| UPS Dataline Suppression | 1 line TEL/DSL (1 in / 1 out) |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced alarm will re-sound to indicate low-battery status |
| Audible Alarm | Audible alarm indicates power-failure overload and low-battery conditions |
| LED Indicators | 5 LEDs indicate line power battery power overload voltage regulation and battery low/replace status |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| VOLTAGE REGULATION | |
| Undervoltage Correction | Input voltages between 90 and 108 are boosted by 14% |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 90 |
| Battery | |
| Battery Access | Battery access door |
| Battery Recharge Rate (Included Batteries) | Less than 4 hours from 10% to 90% |
| Battery Replacement Description | Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 12 |
| Expandable Runtime | No |
| Runtime Full Load (min.) | 3.2 min. (300W) |
| Runtime Half Load (min.) | 14.6 min. (150W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 44 |
| AC Mode Efficiency Rating (100% Load) | 96% |
| Audible Noise | 45 dBA maximum front side 1m |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Input | |
| Input Circuit Breakers | 15A |
| Input Phase | Single-Phase |
| Maximum Input Amps | 6 |
| Nominal Input Voltage(s) Supported | 120V AC |
| Rated input current (Maximum Load) | 5.6A |
| Recommended Electrical Service | 15A 120V |
| UPS Input Connection Type | 5-15P |
| UPS Input Cord Length (ft.) | 10 |
| UPS Input Cord Length (m) | 3.1 |
| Output | |
| Frequency Compatibility | 60 Hz |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | One switchable single-outlet 5-15R load bank |
| Nominal Output Voltage(s) Supported | 110V; 115V; 120V |
| Nominal Voltage Details | 120v nominal output in battery mode |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Output Capacity (kVA) | 0.5 |
| Output Capacity (kW) | 0.3 |
| Output Capacity (VA) | 500 |
| Output Capacity (Watts) | 300 |
| Output Receptacles | (6) 5-15R |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Output Voltage Regulation (Line Mode) | -15% +13% |
| UPS Output Receptacles (Surge Suppression Only) | 6 UPS outlets 1 surge-only outlet |
| Physical | |
| Installation Form Factors Supported with Included Accessories | 2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount |
| Minimum Required Rack Depth (cm) | 38.10 |
| Minimum Required Rack Depth (inches) | 15 |
| Mounting Details | Included mounting brackets provide front-rail installation in 2 or 4 post racks |
| Primary Form Factor | Rackmount; Vertical |
| Primary UPS Depth (mm) | 286 |
| Primary UPS Height (mm) | 44 |
| Primary UPS Width (mm) | 440 |
| Shipping Dimensions (hwd / cm) | 39.12 x 12.19 x 56.13 |
| Shipping Dimensions (hwd / in.) | 15.40 x 4.80 x 22.10 |
| Unit Weight (kg) | 7.98 |
| Unit Weight (lbs.) | 17.6000 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd cm) | 4.39 x 43.99 x 28.60 |
| UPS Power Module Dimensions (hwd in.) | 1.73 x 17.32 x 11.26 |
| UPS Power Module Weight (kg) | 7.98 |
| UPS Power Module Weight (lbs.) | 17.6 |
| Rack Height | 1U |
| Shipping Weight (kg) | 9.48 |
| Shipping Weight (lbs.) | 20.90 |
| Warranty | |
| Warranty/Returns | 30 Days |