Tripp Lite VS450T 450VA 240W Line-Interactive UPS with 4 Outlets - AVR VS Series 120V 50/60 Hz Tower UPS Battery Backup

Tripp Lite VS450T 450VA 240W Line-Interactive UPS with 4 Outlets - AVR VS Series 120V 50/60 Hz Tower

$85.03
Manufacturer:Eaton / Tripp Lite
Model:VS450T
Condition:New
Availability:In Stock
Safeguard your equipment with the Tripp Lite 450VA UPS. This 240W line-interactive UPS with AVR offers battery backup and surge protection for desktops and other sensitive electronics.
Datasheet

The Tripp Lite VS450T UPS Desktop 450VA AVR Battery Back Up is a reliable line-interactive UPS system designed to protect your valuable electronics from power fluctuations. Providing 450VA/240W of power capacity this tower-style UPS offers battery backup during outages ensuring continuous operation for connected devices like desktops workstations and network equipment.

Featuring automatic voltage regulation (AVR) the VS450T corrects minor voltage fluctuations without switching to battery power preserving battery life for when you need it most. It includes four battery backup and surge-protected outlets safeguarding your equipment from surges spikes and brownouts. Ensure your devices stay powered and protected with the Tripp Lite VS450T.

APPLICATIONS
UPS Applications Home/Office Desktop; Retail/Point of Sale; Hospitality
COMMUNICATIONS
Communications Interface None
Network Management Card Description Network management not supported
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number VS450T
FEATURES & SPECIFICATIONS
High Availability UPS Features Automatic Voltage Regulation (AVR); Surge/noise protection
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 145
Low Voltage Transfer to Battery Power (Setpoint) 89
Transfer Time 6 milliseconds
OVERVIEW
UPC Code 037332212887
UPS Type Line-Interactive
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); NOM (Mexico); UL 1778
Product Compliance RoHS; FCC Part 15 Class A (USA)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 316
AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
USER INTERFACE ALERTS & CONTROLS
Audible Alarm Audible alarm indicates low-battery fault overload and replace-battery status
LED Indicators 3 LEDs indicate online mode (green) battery mode (yellow) and fault mode (red)
Switches Controls off/on power status
VOLTAGE REGULATION
Overvoltage Correction Input voltages between 132 and 145 are reduced by 15%
Undervoltage Correction Input voltages between 89 and 108 are boosted by 18%
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 89 to 145
Battery
Battery Recharge Rate (Included Batteries) 8 hours (10% to 90%)
DC System Voltage (VDC) 12
Expandable Runtime No
Runtime Full Load (min.) 0.5 min. (240W)
Runtime Half Load (min.) 5 min. (120W)
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Economy Mode Efficiency Rating (100% Load) 0.95
AC Mode BTU / Hr. (Full Load) 23
AC Mode Efficiency Rating (100% Load) 95%
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 0-90% non-condensing
Storage Temperature Range 5 to 113F (-15 to 45C )
Operating Elevation 0-6562 ft. (0-2000 m)
Input
Input Circuit Breakers 5A
Input Phase Single-Phase
Maximum Input Amps 5
Nominal Input Voltage(s) Supported 120V AC
Rated input current (Maximum Load) 5A
Recommended Electrical Service 15A 120V
UPS Input Connection Type 5-15P
UPS Input Cord Length (ft.) 5
UPS Input Cord Length (m) 1.5
Output
Frequency Compatibility 60 Hz
Frequency Compatibility Details Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.
Individually Controllable Load Banks No
Nominal Output Voltage(s) Supported 110V; 115V; 120V
Nominal Voltage Details 120V sinusoidal in line mode and 120V PWM in battery mode
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
Output Capacity (kVA) 0.45
Output Capacity (kW) 0.24
Output Capacity (VA) 450
Output Capacity (Watts) 240
Output Capacity Details 3.8A @ 120V. (LINE MODE) 110%+/- 10% @ 5 minutes; (BATTERY MODE) 110% +/- 10% @ 5 seconds
Output Receptacles (4) 5-15R
Output Voltage Regulation (Battery Mode) 120V (+/- 10%)
Output Voltage Regulation (Line Mode) 120V (+9% -12%)
Power Factor 0.53
UPS Output Receptacles (Surge Suppression Only) 3 UPS outlets 1 surge-only outlet
Physical
Installation Form Factors Supported with Included Accessories Tower
Primary Form Factor Tower
Primary UPS Depth (mm) 300
Primary UPS Height (mm) 142
Primary UPS Width (mm) 102
Shipping Dimensions (hwd / in.) 8.70 x 5.50 x 13.50
Unit Weight (kg) 3.72
Unit Weight (lbs.) 8.200
UPS Housing Material ABS
UPS Power Module Dimensions (hwd in.) 5.6 x 4 x 11.8
UPS Power Module Weight (kg) 3.72
UPS Power Module Weight (lbs.) 8.2
Shipping Weight (kg) 3.99
Warranty