Datasheet
The Tripp Lite SUINT2200LCD2U is a 2200VA/1980W smart online double-conversion UPS system ensuring continuous regulated AC power to connected equipment even during brownouts and blackouts. Its LCD interface provides real-time status information and the 2U rackmount design optimizes space in data centers and server rooms.
Featuring USB connectivity for monitoring and management this international model supports 208/230V input making it suitable for global deployments. The SUINT2200LCD2U delivers premium power protection for critical IT equipment servers and networking hardware.
| APPLICATIONS | |
| UPS Applications | Mission Critical Applications |
| COMMUNICATIONS | |
| Communications Cable | USB and RS232 cable included |
| Communications Interface | (1) Contact closure; (1) RS-232; (1) Slot for SNMP/Web interface; (1) USB |
| Emergency Power Off (EPO)/Remote On-Off (ROO) | Yes |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | WEBCARDLXE Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; not compatible with WEBCARDLX |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SUINT2200LCD2U |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | High efficiency economy mode operation; Individually controllable load banks |
| High Availability UPS Features | Expandable battery backup; Hot swappable batteries; On-Line/Double-Conversion; Pure sine wave output; Remote management; Surge/noise protection; Zero transfer time |
| LINE / BATTERY TRANSFER | |
| Transfer Time | 0 ms. |
| OVERVIEW | |
| UPC Code | 037332183330 |
| UPS Type | On-Line |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CAN/CSA-C22.2 No. 107.3 (Canada); UL 1778; NOM (Mexico); cTUVus |
| Product Compliance | CE (Europe); FCC (USA); REACH; RoHS |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 296 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
| Audible Alarm | Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions |
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage frequency operating mode alarm function and a variety of additional options |
| LED Indicators | 4 status-indicating LEDs |
| Switches | RPO / ROO |
| VOLTAGE REGULATION | |
| Voltage Regulation Description | Online double-conversion power conditioning |
| Battery | |
| Battery Access | Battery access door |
| Battery Recharge Rate (Included Batteries) | 3 hours recharge to 90% |
| Battery Replacement Description | Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 72 |
| Expandable Runtime | Yes |
| Runtime Full Load (min.) | 6 min. (2000W) |
| Runtime Half Load (min.) | 16.6 min. (1000W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Economy Mode Efficiency Rating (100% Load) | 98 |
| AC Mode Efficiency Rating (100% Load) | 93 |
| Audible Noise | 47 dB at 1m |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 741 |
| Online Mode Heat Dissipation (BTU/Hr) @ Full Load | 513 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-96% non-condensing |
| Storage Temperature Range | With battery: 32 to 104F (0 to 40C); without battery: -13 to 131F (-25 to 55C) |
| Operating Elevation | 0-10000 ft. (0-3000 m) |
| Input | |
| Input Cord Length (ft.) | 6 |
| Input Cord Length (m) | 1.83 |
| Input Phase | Single-Phase |
| Input Plug Type | NEMA L6-20P |
| Maximum Input Amps | 11 |
| Nominal Input Voltage Description | 208V factory default |
| Nominal Input Voltage(s) Supported | 200V AC; 208V AC; 220V AC; 230V AC; 240V AC |
| Power Factor (Input) | 0.99 |
| Rated input current (Maximum Load) | 10.57A |
| Recommended Electrical Service | 208V |
| UPS Input Connection Type | C20 inlet |
| UPS Input Cord Length (ft.) | 6 |
| UPS Input Cord Length (m) | 1.8 |
| Input Current | 10.57A |
| Output | |
| Crest Factor | 3:1 |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Online Mode: Sync with line 5% of nominal line frequency (outside this range: 0.5% of auto-selected nominal frequency). Battery Mode: 0.5% of auto-selected nominal frequency |
| Included Output Power Cables | (2) IEC 10A 6ft. output cables |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | Two switchable load banks. Group 1: Two C13 outlets plus one C19 outlet; Group 2: Two C13 outlets. |
| Nominal Output Voltage(s) Supported | 200V; 208V; 220V; 230V; 240V |
| Nominal Voltage Details | 208V default |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 2.2 |
| Output Capacity (kW) | 2 |
| Output Capacity (VA) | 2200 |
| Output Capacity (Watts) | 2000 |
| Output Capacity Details | 220/230/240V: 2200VA / 2200W;208V(default)/200V: 2200VA / 2000W |
| Output Receptacles | (8) C13; (2) C19 |
| Output Voltage Regulation (Battery Mode) | +/- 2% |
| Output Voltage Regulation (Economy Line Mode) | +/- 1% |
| Output Voltage Regulation (Line Mode) | +/- 1% |
| Power Factor | 0.9 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount |
| Minimum Required Rack Depth (cm) | 68.07 |
| Minimum Required Rack Depth (inches) | 26.8 |
| Mounting Details | 4 post installation accessories included |
| Primary Form Factor | Rackmount |
| Shipping Dimensions (hwd / cm) | 24.00 x 58.01 x 78.00 |
| Shipping Dimensions (hwd / in.) | 9.45 x 22.84 x 30.71 |
| Unit Dimensions (hwd / in.) | 3.410 x 17.330 x 23.820 |
| Unit Weight (kg) | 27.10 |
| Unit Weight (lbs.) | 59.75 |
| UPS Housing Material | Metal |
| Rack Height | 2U |
| Shipping Weight (kg) | 34.10 |
| Shipping Weight (lbs.) | 75.18 |
| Warranty | |
| Warranty/Returns | 30 Days |