Tripp Lite SUINT1000LCD2U SmartOnline 1000VA 900W 208/230V Double-Conversion UPS - 8 Outlets Extended Run Network Card Option LCD USB DB9 2U Rack/Tower
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SmartOnline Series
- UPS Battery Backup
- Search
- Tripp Lite SUINT1000LCD2U SmartOnline 1000VA 900W 208/230V Double-Conversion UPS - 8 Outlets Extended Run Network Card Option LCD USB DB9 2U Rack/Tower
The Tripp Lite SUINT1000LCD2U SmartOnline UPS provides reliable double-conversion power protection for critical 208/230V equipment. With 1kVA/900W capacity and a compact 2U rackmount design it safeguards servers networking gear and other sensitive electronics against outages surges and voltage fluctuations. Features include an LCD status display for at-a-glance monitoring USB and DB9 serial ports for communication and support for optional SNMP network management.
This ENERGY STAR certified UPS offers extended runtime capabilities with optional external battery packs ensuring business continuity during prolonged power failures. Its advanced online topology delivers continuous regulated power isolating connected equipment from raw utility power. The SUINT1000LCD2U is a robust power solution ideal for demanding IT environments.
| APPLICATIONS | |
| UPS Applications | Mission Critical Applications |
| COMMUNICATIONS | |
| Communications Cable | USB and RS232 cable included |
| Communications Interface | (1) Contact closure; (1) RS-232; (1) Slot for SNMP/Web interface; (1) USB |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | WEBCARDLXE Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; not compatible with WEBCARDLX |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SUINT1000LCD2U |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | High efficiency economy mode operation; Individually controllable load banks |
| High Availability UPS Features | Expandable battery backup; Hot swappable batteries; On-Line/Double-Conversion; Pure sine wave output; Remote management; Surge/noise protection; Zero transfer time |
| LINE / BATTERY TRANSFER | |
| Transfer Time | 0 ms. |
| OVERVIEW | |
| UPC Code | 037332185648 |
| UPS Type | On-Line |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CAN/CSA-C22.2 No. 107.3 (Canada); NOM (Mexico); UL 1778; cTUVus |
| Product Compliance | CE (Europe); ENERGY STAR Qualified; RoHS |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 296 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| UPS AC Suppression Joule Rating | 296 |
| UPS AC Suppression Response Time | Instantaneous |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
| Audible Alarm | Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions |
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage frequency operating mode alarm function and a variety of additional options |
| LED Indicators | 4 status-indicating LEDs |
| Switches | RPO / ROO |
| VOLTAGE REGULATION | |
| Voltage Regulation Description | Online double-conversion power conditioning |
| Battery | |
| Battery Access | Battery access door |
| Battery Recharge Rate (Included Batteries) | 3 hours recharge to 90% |
| Battery Replacement Description | Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 48 |
| Expandable Runtime | Yes |
| Runtime Full Load (min.) | 7.3 min. (900W) |
| Runtime Half Load (min.) | 17.9 min. (450W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Economy Mode BTU / Hr. (Full Load) | 96 |
| AC Economy Mode Efficiency Rating (100% Load) | 0.97 |
| AC Mode BTU / Hr. (Full Load) | 267 |
| AC Mode Efficiency Rating (100% Load) | 0.912 |
| Audible Noise | 40dBA |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 438 |
| Online Mode Heat Dissipation (BTU/Hr) @ Full Load | 267 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0 to 96% non-condensing |
| Storage Temperature Range | With battery: 32 to 104F (0 to 40C); without battery: -13 to 131F (-25 to 55C) |
| Operating Elevation | 0-10000 ft. (0-3000 m) |
| Input | |
| Input Phase | Single-Phase |
| Maximum Input Amps | 6 |
| Nominal Input Voltage(s) Supported | 200V AC; 208V AC; 220V AC; 230V AC; 240V AC |
| Power Factor (Input) | 0.99 |
| Rated input current (Maximum Load) | 6A |
| UPS Input Connection Type | C14 inlet |
| Input Current | 6A |
| Input Frequency | 40-70Hz before transfer to battery |
| Output | |
| Crest Factor | 3:1 |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Online Mode: Sync with line 5% of nominal line frequency (outside this range: 0.5% of auto-selected nominal frequency). Battery Mode: 0.5% of auto-selected nominal frequency |
| Included Output Power Cables | (2) IEC 10A 6ft. output cables |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | Two switchable two-outlet load banks |
| Nominal Output Voltage(s) Supported | 200V; 208V; 220V; 230V; 240V |
| Nominal Voltage Details | 208V default |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 1 |
| Output Capacity (kW) | 0.9 |
| Output Capacity (VA) | 1000 |
| Output Capacity (Watts) | 900 |
| Output Capacity Details | 220/230/240V: 1000VA / 1000W;208V(default)/200V: 1000VA / 900W |
| Output Receptacles | (8) C13 |
| Output Voltage Regulation (Battery Mode) | +/- 1% |
| Output Voltage Regulation (Economy Line Mode) | +/- 1% |
| Output Voltage Regulation (Line Mode) | +/- 1% |
| Power Factor | 0.9 |
| Physical | |
| Cooling Method | Fan |
| Included Mounting Accessory Description | 4 post installation accessories included |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount |
| Minimum Required Rack Depth (cm) | 52.58 |
| Minimum Required Rack Depth (inches) | 20.7 |
| Mounting Details | 4 post installation accessories included |
| Primary Form Factor | Rackmount; Tower |
| Shipping Dimensions (hwd / cm) | 24.00 x 55.02 x 60.02 |
| Shipping Dimensions (hwd / in.) | 9.45 x 21.66 x 23.63 |
| Unit Dimensions (hwd / in.) | 3.410 x 17.330 x 17.720 |
| Unit Weight (kg) | 16.50 |
| Unit Weight (lbs.) | 36.38 |
| UPS Housing Material | Metal |
| Rack Height | 2U |
| Shipping Weight (kg) | 23.50 |
| Shipping Weight (lbs.) | 51.81 |
| Warranty | |