Tripp Lite SU3000XLCD SmartOnline 3000VA 2700W 120V Double-Conversion UPS - 5 Outlets Extended Run Network Card Option LCD USB DB9 Tower
$1,993.70
Manufacturer:Eaton / Tripp Lite
Model:SU3000XLCD
Condition:New
Availability:In Stock
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SmartOnline Series
- UPS Battery Backup
- Search
- Tripp Lite SU3000XLCD SmartOnline 3000VA 2700W 120V Double-Conversion UPS - 5 Outlets Extended Run Network Card Option LCD USB DB9 Tower
Datasheet
The Tripp Lite SU3000XLCD 3000VA/2700W UPS System provides premium online double-conversion protection for critical server network and telecommunications equipment. Featuring true sine wave output it safeguards connected equipment from blackouts brownouts voltage fluctuations and line noise. The included USB and DB9 ports enable automatic shutdown of connected systems.
With an intuitive front-panel LCD interface monitoring UPS status and configuration is easy. Network management capabilities are also included via SNMP/RT giving administrators remote access to critical UPS information. The tower format allows for convenient placement in server rooms or network closets.
| APPLICATIONS | |
| UPS Applications | Mission Critical Applications |
| COMMUNICATIONS | |
| Communications Cable | USB and RS232 cabling included |
| Communications Interface | (1) Contact closure; (1) RS-232; (1) Slot for SNMP/Web interface; (1) USB |
| Emergency Power Off (EPO)/Remote On-Off (ROO) | Yes |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | WEBCARDLXE Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; not compatible with WEBCARDLX |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SU3000XLCD |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | High efficiency economy mode operation; Individually controllable load banks |
| High Availability UPS Features | Expandable battery backup; On-Line/Double-Conversion; Pure sine wave output; Remote management; Surge/noise protection; Zero transfer time |
| LINE / BATTERY TRANSFER | |
| Transfer Time | 0 ms. |
| OVERVIEW | |
| UPC Code | 037332158871 |
| UPS Type | On-Line |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CAN/CSA-C22.2 No. 107.3 (Canada); UL 1778; NOM (Mexico); cTUVus |
| Product Compliance | CE (Europe); FCC (USA); REACH; RoHS |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 190 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
| Audible Alarm | Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions |
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage frequency operating mode alarm function and a variety of additional options |
| LED Indicators | 4 status-indicating LEDs |
| Switches | RPO / ROO |
| VOLTAGE REGULATION | |
| Voltage Regulation Description | Online double-conversion power conditioning |
| Battery | |
| Battery Access | Battery access door |
| Battery Recharge Rate (Included Batteries) | 3 hours recharge to 90% |
| Battery Replacement Description | User replaceable batteries |
| DC System Voltage (VDC) | 96 |
| Expandable Runtime | Yes |
| Runtime Full Load (min.) | 5.7 min. (2700W) |
| Runtime Half Load (min.) | 16.7 min. (1350W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode Efficiency Rating (100% Load) | 89% |
| Audible Noise | 52 dB |
| Online Mode Heat Dissipation (BTU/Hr) @ Full Load | 911 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-96% non-condensing |
| Storage Temperature Range | With battery: 32 to 104F (0 to 40C); without battery: -13 to 131F (-25 to 55C) |
| Operating Elevation | 0-10000 ft. (0-3000 m) |
| Input | |
| Input Cord Length (ft.) | 8 |
| Input Cord Length (m) | 2.44 |
| Input Phase | Single-Phase |
| Input Plug Type | NEMA L5-30P |
| Maximum Input Amps | 24 |
| Nominal Input Voltage Description | 120V factory default |
| Nominal Input Voltage(s) Supported | 100V AC; 110V AC; 120V AC; 127V AC |
| Power Factor (Input) | 0.99 |
| Rated input current (Maximum Load) | 24A |
| Recommended Electrical Service | 120V |
| UPS Input Connection Type | L5-30P |
| UPS Input Cord Length (ft.) | 8 |
| UPS Input Cord Length (m) | 2.4 |
| Input Current | 24A |
| Output | |
| Crest Factor | 3:1 |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Online Mode: Sync with line 5% of nominal line frequency (outside this range: 0.5% of auto-selected nominal frequency). Battery Mode: 0.5% of auto-selected nominal frequency |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | Two switchable two-outlet load banks |
| Nominal Output Voltage(s) Supported | 100V; 110V; 120V |
| Nominal Voltage Details | 120V default |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 3 |
| Output Capacity (kW) | 2.7 |
| Output Capacity (VA) | 3000 |
| Output Capacity (Watts) | 2700 |
| Output Receptacles | (4) 5-20R; (1) L5-30R |
| Output Voltage Regulation (Battery Mode) | +/- 3% |
| Output Voltage Regulation (Economy Line Mode) | +/- 2% |
| Output Voltage Regulation (Line Mode) | +/- 2% |
| Power Factor | 0.9 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | Tower |
| Primary Form Factor | Tower |
| Shipping Dimensions (hwd / cm) | 49.02 x 32.00 x 57.51 |
| Shipping Dimensions (hwd / in.) | 19.30 x 12.60 x 22.64 |
| Unit Dimensions (hwd / in.) | 13.630 x 8.430 x 16.230 |
| Unit Weight (kg) | 33.40 |
| Unit Weight (lbs.) | 73.64 |
| UPS Housing Material | Metal |
| Shipping Weight (kg) | 37.20 |
| Shipping Weight (lbs.) | 82.02 |
| Warranty | |
| Warranty/Returns | 30 Days |