Tripp Lite SU3000LCD2UHVTF SmartOnline 208/120V UPS With Step-Down Transformer - On-Line Double-Conversion 3000VA 2700W 4U Network Card Option UPS Battery Backup

Tripp Lite SU3000LCD2UHVTF SmartOnline 208/120V UPS With Step-Down Transformer - On-Line Double-Conversion 3000VA 2700W 4U Network Card Option

$3,539.39
Manufacturer:Eaton / Tripp Lite
Model:SU3000LCD2UHVTF
Condition:New
Availability:In Stock
The Tripp Lite SU3000LCD2UHVTF is a 3000VA/2700W SmartOnline UPS with step-down transformer. Provides 208/120V double-conversion power protection and network management capabilities (card optional).
Datasheet

The Tripp Lite SU3000LCD2UHVTF SmartOnline 208/120V UPS with Step-Down Transformer offers premium double-conversion power protection for critical equipment. Delivering 3000VA/2700W in a 4U rackmount form factor this UPS safeguards against outages surges and voltage fluctuations ensuring continuous operation.

Featuring online double-conversion technology the SU3000LCD2UHVTF isolates connected equipment from raw utility power providing consistent conditioned output. It supports network management capabilities via an optional network card for remote monitoring and control. The step-down transformer allows for compatibility with 208V input and 120V output requirements.

APPLICATIONS
UPS Applications High-End Desktop/Small Network
COMMUNICATIONS
Communications Cable USB and DB9 cabling included
Communications Interface Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
Network Management Card Description Network management card optional
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 plus assignable contact closure pin functions for On-battery On bypass Output-on and Low-battery conditions and remote Shutdown Output-off Reboot and Power-toggle operations
PowerAlert Software For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert
WatchDog Compatibility Supports Watchdog application OS and hard-reboot restart options for remote applications
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number SU3000LCD2UHVTF
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
Green Energy-Saving Features High efficiency economy mode operation; Individually controllable load banks
Grounding Details Back panel grounding lug included
High Availability UPS Features Automatic inverter bypass; Hot swappable batteries; Remote management; Surge/noise protection; Zero transfer time; Auto Probe Monitoring (requires WEBCARDLXE)
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 288V
Low Voltage Transfer to Battery Power (Setpoint) 160V (100% load) 140V (66% load) 120V (33% load)
Transfer Time 0 ms
OVERVIEW
UPC Code 037332241719
UPS Type On-Line
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); UL 1778
Product Compliance RoHS; FCC Part 15 Class A (USA)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 570
AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
UPS Dataline Suppression Details Single line dialup / network dataline protection included
USER INTERFACE ALERTS & CONTROLS
Alarm Cancel Operation Power-fail alarm can be silenced by following on-screen prompts
Audible Alarm Audible alarm indicates power failure low battery overload and fault
Front Panel LCD Display Interactive front-panel LCD interface reports UPS operating mode detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options
LED Indicators 4 front panel LEDs: AC input (green) AC output (green) Battery (yellow) Fault (red)
Switches 5 front panel switches: On/Off Up Down and Escape
VOLTAGE REGULATION
Overvoltage Correction 2% output voltage regulation during overvoltages to 288
Undervoltage Correction 2% output voltage regulation during undervoltages to 160V (100% load) 130V (70% load) 100V (30% load)
Voltage Regulation Description Online double-conversion power conditioning
Battery
Battery Access Front panel battery access door
Battery Recharge Rate (Included Batteries) 3.0 hours from 10% to 90% (typical full load discharge)
Battery Replacement Description Hot-swappable replaceable batteries
DC System Voltage (VDC) 72
Expandable Runtime Yes
Runtime Full Load (min.) 5 min. (2700W)
Runtime Half Load (min.) 13.5 min. (1350W)
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Economy Mode BTU / Hr. (Full Load) 588
AC Economy Mode Efficiency Rating (100% Load) >95%
AC Mode BTU / Hr. (Full Load) 933
AC Mode Efficiency Rating (100% Load) >90%
Audible Noise <50dB at front side 1M
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load 1399
Online Mode Heat Dissipation (BTU/Hr) @ Full Load 933
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 5 to 95% non-condensing
Storage Temperature Range 5 to 122F (-15 to 50C)
Input
Input Phase Single-Phase
Maximum Input Amps 15
Nominal Input Voltage(s) Supported 208V AC
Rated input current (Maximum Load) 14.97A
Recommended Electrical Service 208V 20A
UPS Input Connection Type L6-20P
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3.1
Output
Crest Factor 3:1
Frequency Compatibility 60 Hz
Frequency Compatibility Details IMPORTANT! Please ensure the UPS is configured for 60Hz output when used with the included step-down transformer module
Individually Controllable Load Banks Yes
Load Management Receptacles Two switchable outlet load banks (2 NEMA 6-15/20R outlets per bank)
Nominal Output Voltage(s) Supported 120V; 208V
Nominal Voltage Details IMPORTANT! Please ensure the UPS is configured for 208V output when used with the included step-down transformer module
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Output Capacity (kVA) 3
Output Capacity (kW) 2.7
Output Capacity (VA) 3000
Output Capacity (Watts) 2700
Output Capacity Details OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously 125% for 3 minutes 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).
Output Circuit Breakers Included 2U transformer module includes four 20A 120V circuit breakers (each protects 3 NEMA 5-15/20R outlets).
Output Receptacles (12) 5-15/20R; (6) 6-15/20R; (2) L6-20R
Output Voltage Regulation (Battery Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Line Mode) +/- 2%
Power Factor 0.9
Physical
Cooling Method Fan
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Minimum Required Rack Depth (cm) 71.12
Minimum Required Rack Depth (inches) 28
Minimum Required Rack Depth with External Battery Pack (cm) 77
Minimum Required Rack Depth with External Battery Pack (in.) 30.25
Minimum Required Rack Depth without External Battery Pack (cm) 74
Minimum Required Rack Depth without External Battery Pack (in.) 29.25
Mounting Details 4 post installation accessories included (2 sets)
Primary Form Factor Rackmount
Primary UPS Depth (mm) 616
Primary UPS Height (mm) 177
Primary UPS Width (mm) 440
Shipping Dimensions (hwd / in.) 37.75 x 40.00 x 48.00
Unit Dimensions (hwd / in.) 6.960 x 17.320 x 24.250
Unit Weight (kg) 60.70
Unit Weight (lbs.) 133.820
UPS Housing Material Metal
UPS Power Module Dimensions (hwd in.) 6.96 x 17.34 x 24.25
UPS Power Module Weight (kg) 60.70
UPS Power Module Weight (lbs.) 133.82
Rack Height 4U
Shipping Weight (kg) 87.09
Warranty
Warranty/Returns 30 Days