Tripp Lite SU1500LCD1U SmartOnline 1500VA 1440W 120V Double-Conversion UPS - 5 Outlets Network Card Option LCD USB DB9 1U Rack UPS Battery Backup

Tripp Lite SU1500LCD1U SmartOnline 1500VA 1440W 120V Double-Conversion UPS - 5 Outlets Network Card Option LCD USB DB9 1U Rack

$945.61
Manufacturer:Eaton / Tripp Lite
Model:SU1500LCD1U
Condition:New
Availability:In Stock
Datasheet

The Tripp Lite SU1500LCD1U SmartOnline UPS safeguards mission-critical equipment with 1500VA/1440W of reliable double-conversion power protection. This 1U rackmount unit features five outlets an intuitive LCD status display and both USB and DB9 communication ports for comprehensive monitoring and control.

Ideal for servers networking gear and other sensitive electronics the SU1500LCD1U provides continuous regulated power protecting against outages surges and voltage fluctuations. Its advanced features and compact design make it a perfect solution for demanding IT environments.

APPLICATIONS
UPS Applications Mission Critical Applications
COMMUNICATIONS
Communications Cable USB and RS232 cabling included
Communications Interface Contact closure; EPO (emergency power off); RS-232; Slot for SNMP/Web interface; USB (HID enabled)
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert
WatchDog Compatibility Supports Watchdog application OS and hard-reboot restart options for remote applications
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number SU1500LCD1U
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
Green Energy-Saving Features High efficiency economy mode operation; Individually controllable load banks
Grounding Details Includes back panel grounding lug
High Availability UPS Features Automatic inverter bypass; Hot swappable batteries; Remote management; Surge/noise protection; Zero transfer time; Auto Probe Monitoring (requires WEBCARDLXE)
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 150
Low Voltage Transfer to Battery Power (Setpoint) 50
Transfer Time 0 ms
OVERVIEW
UPC Code 037332238122
UPS Type On-Line
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); UL 1778
Product Compliance RoHS; ENERGY STAR Qualified; FCC Part 15 Class A (USA)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 540
AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
USER INTERFACE ALERTS & CONTROLS
Alarm Cancel Operation Power-fail alarm can be temporarily silenced using alarm-cancel switch
Audible Alarm Audible alarm indicates UPS startup power-failure low-battery overload and UPS fault conditions
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage frequency operating mode alarm function and a variety of additional options (see manual)
LED Indicators Two front panel LEDs indicate AC Output status (green) and Shutdown / Fault condition (red)
Switches 2 switches control off/on power status and alarm-cancel operation; 2 additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options
VOLTAGE REGULATION
Overvoltage Correction Corrects overvoltages to 150V
Undervoltage Correction Corrects undervoltages to 50V
Voltage Regulation Description Online double-conversion power conditioning maintains 3% output voltage regulation during brownouts and overvoltages
Battery
Battery Recharge Rate (Included Batteries) Less than 8 hours recharge to 90% (typical full load discharge)
Battery Replacement Description Hot-swappable user replaceable batteries
DC System Voltage (VDC) 48
Expandable Runtime No
Runtime Full Load (min.) 3 min. (1440W)
Runtime Half Load (min.) 10 min. (720W)
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Economy Mode BTU / Hr. (Full Load) 100.274
AC Economy Mode Efficiency Rating (100% Load) 98%
AC Mode BTU / Hr. (Full Load) 545.92
AC Mode Efficiency Rating (100% Load) 90%
Audible Noise 65 dBA at 1m front side
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load 799
Online Mode Heat Dissipation (BTU/Hr) @ Full Load 545
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 5% to 95% non-condensing
Storage Temperature Range 5 to 122F (-15 to 50C)
Operating Elevation 0-10000 ft. (0-3000 m)
Input
Input Circuit Breakers 20A
Input Phase Single-Phase
Maximum Input Amps 13
Nominal Input Voltage Description 120V factory default
Nominal Input Voltage(s) Supported 100V AC; 120V AC; 127V AC
Rated input current (Maximum Load) 13A (100V); 12A (120V); 11.3A (127V)
Recommended Electrical Service 15A 120V
UPS Input Connection Type 5-15P
UPS Input Cord Length (ft.) 6
UPS Input Cord Length (m) 1.8
Output
Crest Factor 3:1
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz.FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz.
Individually Controllable Load Banks Yes
Load Management Receptacles Two switchable NEMA 5-15R outlet banks (Bank 1: 2 outlets / Bank 2: 3 outlets)
Nominal Output Voltage(s) Supported 100V; 120V; 127V
Nominal Voltage Details 120V factory-default nominal voltage
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Output Capacity (kVA) 1.44
Output Capacity (kW) 1.44
Output Capacity (VA) 1440
Output Capacity (Watts) 1440
Output Capacity Details ON LINE MODE: Maximum output capacity is reduced to 1296 watts at 100V nominal; FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 864 watts / 100V 778 watts) OVERLOAD CAPACITY- Supports inverter operation up to 105% load continuously 106-115% load for 1 minute; 116-130% load for 12 seconds; 131-149% for 2 seconds and >150% load for 0 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
Output Receptacles (5) 5-15R
Output Voltage Regulation (Battery Mode) +/- 3%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Line Mode) +/- 3%
Power Factor 1.0
Physical
Cooling Method Fan
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Minimum Required Rack Depth (cm) 78.74
Minimum Required Rack Depth (inches) 31
Minimum Required Rack Depth without External Battery Pack (cm) 79
Minimum Required Rack Depth without External Battery Pack (in.) 30.95
Mounting Details Includes 4 post rackmount installation accessories; Included mounting brackets support front-to-rear rail distances of 635 to 914mm
Primary Form Factor Rackmount
Primary UPS Depth (mm) 710
Primary UPS Height (mm) 44
Primary UPS Width (mm) 440
Shipping Dimensions (hwd / in.) 6.10 x 22.83 x 32.68
Unit Dimensions (hwd / in.) 1.730 x 17.320 x 27.950
Unit Weight (kg) 20.50
Unit Weight (lbs.) 45.190
UPS Housing Material Steel
UPS Power Module Dimensions (hwd in.) 1.73 x 17.32 x 27.950
UPS Power Module Weight (kg) 20.50
UPS Power Module Weight (lbs.) 45.19
Rack Height 1U
Shipping Weight (kg) 25.79
Warranty
Warranty/Returns 30 Days