The Tripp Lite SMART750SLT 750VA Smart UPS provides reliable battery backup and surge protection for connected devices during power outages and fluctuations. Its automatic voltage regulation (AVR) corrects minor voltage variations without using battery power extending battery life.
This tower UPS offers versatile connectivity options including USB DB9 serial SNMP and RJ45 for network management. Ideal for protecting computers servers and other sensitive electronics in home or office environments.
| APPLICATIONS | |
| UPS Applications | Large Network; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality |
| COMMUNICATIONS | |
| Communications Cable | USB and DB9 cabling included |
| Communications Interface | DB9 Serial; Slot for SNMP/Web interface; USB |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMART750SLT |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS |
| High Availability UPS Features | Auto Probe Monitoring (requires WEBCARDLXE); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 145V (120V) 133V (110V) 121V (100V); Voltage setpoints 5% tolerance |
| Low Voltage Transfer to Battery Power (Setpoint) | 95V (120V) 87V (110V) 83V (100V); Voltage setpoints 5% tolerance |
| Transfer Time | 4-8 milliseconds |
| OVERVIEW | |
| UPC Code | 037332124395 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); NOM (Mexico); UL 1778 |
| Product Compliance | RoHS |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 480 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| UPS Dataline Suppression | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch |
| Audible Alarm | Audible alarm indicates power failure and overload conditions |
| LED Indicators | LEDs indicate line power battery power AVR overload and replace battery status - with a 3-LED level meter for load and battery charge level |
| Site Wiring Fault Indication | Rear panel site wiring fault LED |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Voltage reduction of 12% applies when input is 127 to 145 (120v) 116 to 133 (110v) 106 to 121 (100v) |
| Severe Undervoltage Correction | Voltage boost of 32% applies when input is 83 to 95 (120v only); Voltage setpoints 5% tolerance |
| Undervoltage Correction | Voltage boost of 17% applies when input is 96 to 108 (120v) 87 to 99 (110v) 83 to 90 (100v); Voltage setpoints5% tolerance |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145 (120v) 87 to 133 (110v) 83 to 121 (100v) |
| Battery | |
| Battery Access | Battery access door |
| Battery Recharge Rate (Included Batteries) | Less than 8 hours from 10% to 90% (typical full load discharge) |
| Battery Replacement Description | Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 24 |
| Expandable Runtime | No |
| Runtime Full Load (min.) | 6.5 min. (500W) |
| Runtime Half Load (min.) | 17.8 min. (250W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 70 |
| AC Mode Efficiency Rating (100% Load) | 96% |
| Audible Noise | Audible Noise < 50 dBA at Front Side 1 Meter |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Input | |
| Input Phase | Single-Phase |
| Maximum Input Amps | 12 |
| Nominal Input Voltage(s) Supported | 100V AC; 110V AC; 120V AC |
| Rated input current (Maximum Load) | 12A |
| Recommended Electrical Service | 15A 120V |
| UPS Input Connection Type | 5-15P |
| UPS Input Cord Length (ft.) | 6 |
| UPS Input Cord Length (m) | 1.8 |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Automatic frequency selection |
| Individually Controllable Load Banks | No |
| Nominal Output Voltage(s) Supported | 100V; 110V; 120V |
| Nominal Voltage Details | 120V default (voltage selection via back panel switches) |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 0.75 |
| Output Capacity (kW) | 0.5 |
| Output Capacity (VA) | 750 |
| Output Capacity (Watts) | 500 |
| Output Receptacles | (8) 5-15R |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Output Voltage Regulation (Line Mode) | -13% +15% |
| Power Factor | 0.7 |
| UPS Output Receptacles (Surge Suppression Only) | 4 UPS outlets 4 surge-only outlets |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | Tower |
| Primary Form Factor | Tower |
| Primary UPS Depth (mm) | 337 |
| Primary UPS Height (mm) | 259 |
| Primary UPS Width (mm) | 173 |
| Shipping Dimensions (hwd / cm) | 35.31 x 24.38 x 45.97 |
| Shipping Dimensions (hwd / in.) | 13.90 x 9.60 x 18.10 |
| Unit Weight (kg) | 15.47 |
| Unit Weight (lbs.) | 34.1000 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd cm) | 25.91 x 17.27 x 33.66 |
| UPS Power Module Dimensions (hwd in.) | 10.2 x 6.8 x 13.25 |
| UPS Power Module Weight (kg) | 15.47 |
| UPS Power Module Weight (lbs.) | 34.1 |
| Shipping Weight (kg) | 16.51 |
| Shipping Weight (lbs.) | 36.40 |
| Warranty | |
| Warranty/Returns | 30 Days |