Tripp Lite SMART5000XFMRXL SmartPro 208 & 120V 5kVA 3.75kW Line-Interactive Sine Wave UPS 3U Extended Run Network Card Options USB DB9
$4,039.09
Manufacturer:Eaton / Tripp Lite
Model:SMART5000XFMRXL
Condition:New
Availability:In Stock
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SMART Series
- UPS Battery Backup
- Tripp Lite SMART5000XFMRXL SmartPro 208 & 120V 5kVA 3.75kW Line-Interactive Sine Wave UPS 3U Extended Run Network Card Options USB DB9
Datasheet
The Tripp Lite SMART5000XFMRXL 5000VA Smart Online UPS system provides dependable battery backup and AC power conditioning for connected equipment. With a capacity of 5000VA/3750W automatic voltage regulation (AVR) and USB/DB9 communication ports it safeguards sensitive electronics during power fluctuations and outages. Its 3U rackmount design makes it ideal for network closets and server rooms.
This UPS offers extended runtime capabilities through optional external battery packs. It provides advanced surge suppression to protect against damaging voltage spikes. The included monitoring software allows for remote management and graceful shutdown of connected systems minimizing data loss and downtime during extended power failures.
| APPLICATIONS | |
| UPS Applications | Large Network |
| COMMUNICATIONS | |
| Communications Cable | USB and DB9 cabling included |
| Communications Interface | DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMART5000XFMRXL |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
| Grounding Details | Back panel grounding lug |
| High Availability UPS Features | Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 260 |
| Low Voltage Transfer to Battery Power (Setpoint) | 167 |
| Transfer Time | 7 ms (AC to Battery); 1 ms (Battery to AC) typical |
| OVERVIEW | |
| UPC Code | 037332121462 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); CAN/CSA-C22.2 No. 107.3 (Canada); IEC/EN 62040; NOM (Mexico); UL 1778 |
| Product Compliance | RoHS; FCC Part 15 Class A (USA) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 1020 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced alarm will re-sound to indicate low-battery status |
| Audible Alarm | Audible alarm indicates power-failure overload and low-battery conditions |
| LED Indicators | 5 LEDs indicate line power battery power overload voltage regulation and battery low/replace status |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Input voltages between 228 and 260 are reduced by 12% |
| Undervoltage Correction | Input voltages between 167 and 194 are boosted by 12% |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 167 to 260 |
| Battery | |
| Battery Access | Front panel battery access door |
| Battery Recharge Rate (Included Batteries) | 6.8 hours from 10% to 90% (typical full load discharge) |
| Battery Replacement Description | Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 48 |
| Expandable Runtime | Yes |
| Runtime Full Load (min.) | 8.5 min. (3750W) |
| Runtime Half Load (min.) | 20 min. (1875W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 366 |
| AC Mode Efficiency Rating (100% Load) | 97% |
| Audible Noise | 45 dBA maximum front side 1m |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 5 to 95% non-condensing |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Input | |
| Input Phase | Single-Phase |
| Maximum Input Amps | 24 |
| Nominal Input Voltage(s) Supported | 208V AC |
| Rated input current (Maximum Load) | 24A |
| Recommended Electrical Service | 30A 208V |
| UPS Input Connection Type | L6-30P |
| UPS Input Cord Length (ft.) | 10 |
| UPS Input Cord Length (m) | 3.1 |
| Output | |
| Frequency Compatibility | 60 Hz |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | Eight switchable single-outlet 5-15/20R load banks |
| Nominal Output Voltage(s) Supported | 110V; 115V; 120V; 208V |
| Nominal Voltage Details | 208/120V nominal output in battery mode |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 5 |
| Output Capacity (kW) | 3.75 |
| Output Capacity (VA) | 5000 |
| Output Capacity (Watts) | 3750 |
| Output Circuit Breakers | 20A double pole breaker supports L6-20R outlets 20A branch rated breaker (x2) supports 4 5-15/20R outlets each L6-30R outlet is unbreakered |
| Output Receptacles | (8) 5-15/20R; (2) L6-20R; (1) L6-30R |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Output Voltage Regulation (Line Mode) | 208 & 120V (+/- 10%) |
| Power Factor | 0.75 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount |
| Minimum Required Rack Depth (cm) | 71.12 |
| Minimum Required Rack Depth (inches) | 28 |
| Minimum Required Rack Depth with External Battery Pack (cm) | 81 |
| Minimum Required Rack Depth with External Battery Pack (in.) | 32 |
| Minimum Required Rack Depth without External Battery Pack (cm) | 76 |
| Minimum Required Rack Depth without External Battery Pack (in.) | 30 |
| Primary Form Factor | Rackmount |
| Primary UPS Depth (mm) | 635 |
| Primary UPS Height (mm) | 132 |
| Primary UPS Width (mm) | 445 |
| Shipping Dimensions (hwd / cm) | 30.48 x 58.42 x 83.82 |
| Shipping Dimensions (hwd / in.) | 12.00 x 23.00 x 33.00 |
| Unit Weight (kg) | 65.00 |
| Unit Weight (lbs.) | 143.3000 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd cm) | 13.21 x 44.45 x 63.50 |
| UPS Power Module Dimensions (hwd in.) | 5.2 x 17.5 x 25 |
| UPS Power Module Weight (kg) | 65.00 |
| UPS Power Module Weight (lbs.) | 143.3 |
| Rack Height | 3U |
| Shipping Weight (kg) | 86.79 |
| Shipping Weight (lbs.) | 191.33 |
| Warranty | |
| Warranty/Returns | 30 Days |