Tripp Lite SMART2500XLHG SmartPro 120V 2.2kVA 1.92kW UL 60601-1 Medical-Grade Line-Interactive UPS Extended Run SNMPWEBCARD Option Full Isolation USB DB9 Serial
$2,142.75
Manufacturer:Eaton / Tripp Lite
Model:SMART2500XLHG
Condition:New
Availability:In Stock
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SMART Series
- UPS Battery Backup
- Tripp Lite SMART2500XLHG SmartPro 120V 2.2kVA 1.92kW UL 60601-1 Medical-Grade Line-Interactive UPS Extended Run SNMPWEBCARD Option Full Isolation USB DB9 Serial
Datasheet
The Tripp Lite SMART2500XLHG 2200VA/1920W Smart AVR Medical UPS provides reliable battery backup power and surge protection for critical medical equipment. Its automatic voltage regulation (AVR) corrects brownouts and overvoltages without using battery power extending runtime. This tower UPS features USB and DB9 ports for convenient monitoring and control.
Designed for hospital and medical environments the SMART2500XLHG offers advanced features including a user-replaceable battery audible alarms and diagnostic LEDs. It ensures the continuous operation of essential medical devices during power outages protecting patients and sensitive equipment.
| APPLICATIONS | |
| UPS Applications | Hospital/Medical |
| COMMUNICATIONS | |
| Communications Cable | USB and DB9 serial cabling included |
| Communications Interface | USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMART2500XLHG |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| High Availability UPS Features | Hot swappable batteries; Auto Probe Monitoring (requires WEBCARDLXE); Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 143 |
| Low Voltage Transfer to Battery Power (Setpoint) | 81 |
| Transfer Time | 2-4 milliseconds |
| OVERVIEW | |
| UPC Code | 037332168283 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); UL 1778; UL 60601-1; NOM (Mexico) |
| Product Compliance | RoHS; FCC Part 15 Class A (USA) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 940 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced alarm will re-sound to indicate low-battery status |
| Audible Alarm | Audible alarm indicates power-failure overload and low-battery conditions |
| LED Indicators | 5 LEDs indicate line power battery power overload voltage regulation and battery low/replace status |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Input voltages between 126 and 143 are reduced by 9% |
| Severe Undervoltage Correction | Input voltages between 81 and 95 are boosted by 21% |
| Undervoltage Correction | Input voltages between 96 and 106 are boosted by 10% |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143 |
| Battery | |
| Battery Access | Battery access door |
| Battery Recharge Rate (Included Batteries) | 4.5 hours MAX (10% to 90% capacity) Internal batteries only |
| Battery Replacement Description | Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 48 |
| Expandable Runtime | Yes |
| Runtime Full Load (min.) | 4.4 min. (1920W) |
| Runtime Half Load (min.) | 13 min. (960W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Economy Mode Efficiency Rating (100% Load) | 0.94 |
| AC Mode BTU / Hr. (Full Load) | 162.8 |
| AC Mode Efficiency Rating (100% Load) | 94% |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 315.2 |
| Battery Mode Heat Dissipation (BTU/Hr) @ Half Load | 190.5 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Operating Elevation | 0-6562 ft. (0-2000 m) |
| Input | |
| Input Circuit Breakers | 2 x 20A |
| Input Phase | Single-Phase |
| Maximum Input Amps | 16 |
| Nominal Input Voltage(s) Supported | 120V AC |
| Rated input current (Maximum Load) | 16 A |
| Recommended Electrical Service | 20A 120V |
| Total Harmonic Distortion | <3% |
| UPS Input Connection Type | C20 inlet |
| UPS Input Cord Length (ft.) | 6 |
| UPS Input Cord Length (m) | 1.8 |
| Isolation | |
| Leakage Current | Equal to 100 microamps |
| Output Isolation Transformer | Hospital grade load isolation transformer |
| Output | |
| Frequency Compatibility | 60 Hz |
| Frequency Compatibility Details | Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. |
| Individually Controllable Load Banks | No |
| Nominal Output Voltage(s) Supported | 115V; 120V |
| Nominal Voltage Details | 120V sinusoidal in line mode and 120V sinusoidal in battery mode |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 2.2 |
| Output Capacity (kW) | 1.92 |
| Output Capacity (VA) | 2200 |
| Output Capacity (Watts) | 1920 |
| Output Capacity Details | 16A @ 120V. (LINE MODE) 110%+/- 10% @ 5 minutes; (BATTERY MODE) 110% +/- 10% @ 5 seconds |
| Output Receptacle Details | Hospital grade output receptacles |
| Output Receptacles | (4) 5-15/20R; (4) C13 |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Output Voltage Regulation (Line Mode) | -18% +8% |
| Power Factor | 0.87 |
| UPS Output Receptacles (Surge Suppression Only) | 4 UPS outlets 4 surge-only outlets |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | Tower |
| Primary Form Factor | Tower |
| Primary UPS Depth (mm) | 485 |
| Primary UPS Height (mm) | 247 |
| Primary UPS Width (mm) | 226 |
| Shipping Dimensions (hwd / cm) | 40.64 x 35.56 x 60.96 |
| Shipping Dimensions (hwd / in.) | 16.00 x 14.00 x 24.00 |
| Unit Weight (kg) | 33.25 |
| Unit Weight (lbs.) | 73.3000 |
| UPS Housing Material | PVC |
| UPS Power Module Dimensions (hwd cm) | 24.69 x 22.61 x 48.49 |
| UPS Power Module Dimensions (hwd in.) | 9.72 x 8.90 x 19.09 |
| UPS Power Module Weight (kg) | 36.97 |
| UPS Power Module Weight (lbs.) | 81.5 |
| Shipping Weight (kg) | 45.36 |
| Shipping Weight (lbs.) | 100.00 |
| Warranty | |