Tripp Lite SMART1548ET 120VAC 48VDC 2000VA 1600W Extreme Temperature Network UPS for Industrial and Traffic Networks 3U Hardwire TAA
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SMART Series
- UPS Battery Backup
- Search
- Tripp Lite SMART1548ET 120VAC 48VDC 2000VA 1600W Extreme Temperature Network UPS for Industrial and Traffic Networks 3U Hardwire TAA
The Tripp Lite SMART1548ET Extreme Temperature UPS System provides reliable 1500VA/1200W battery backup and surge protection for connected equipment in industrial and traffic network applications. Its 48V DC output makes it uniquely suitable for powering devices with specific voltage requirements. Designed for 3U rackmount installation the SMART1548ET features a network card slot for remote monitoring and management as well as dry-contact ports for integration with other systems.
With its extreme temperature tolerance the SMART1548ET ensures consistent performance in challenging environments. The hardwire input connection allows for secure and permanent power supply integration. This UPS is an ideal solution for maintaining uptime and protecting valuable equipment in demanding industrial and traffic network infrastructures.
| APPLICATIONS | |
| UPS Applications | Mission Critical Applications; Extreme Temperature Applications |
| COMMUNICATIONS | |
| Communications Interface | DB9 Serial; Slot for SNMP/Web interface; USB |
| Input Dry Contact Ports | 1 set of input dry contacts generate an alarm of configurable input conditions when pins 1&2 are shorted; Rating: 300VDC/12A; Wiring Gauge: Up to 12AWG |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | WEBCARDLXMINI network management card option supports operation from 0C to 70C as measured inside the UPS; Built-in USB and Serial ports support UPS configuration via Windows Hyperterminal session |
| Output Dry Contact Ports | 6 sets of output dry contacts support normally-open or normally-closed signaling of configurable UPS conditions; Rating: 300VDC/12A; Wiring Gauge: Up to 12AWG |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMART1548ET |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Yes |
| Grounding Details | Grounding lug connector provides a permanent ground connection for the UPS |
| High Availability UPS Features | Automatic Voltage Regulation (AVR); Surge/noise protection; Extreme Operating Temperature |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 152V (default adjustable from 120 to 152V) |
| Low Voltage Transfer to Battery Power (Setpoint) | 88V (default adjustable from 88 to 120V) |
| Transfer Time | UPS mode: 10ms (typical) / 12ms (max); Generator mode: 20ms (typical) / 22ms (max) |
| OVERVIEW | |
| UPC Code | 037332241207 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); NOM (Mexico); UL 1778 |
| Product Compliance | RoHS; Trade Agreements Act (TAA) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 474 |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Audible Alarm | Audible alarm reports Battery mode operation Battery low status Overload and UPS Fault conditions |
| Front Panel LCD Display | Four line text-based front panel LCD provides full access to UPS status alarms faults events settings and control options |
| LED Indicators | Set of 3 front panel LEDs report AC output status (green) Alarm condition (yellow) and Fault condition (red) |
| Switches | All three front-panel circuit breakers serve as power switches required to energize the UPS (DC INPUT AC INPUT AC OUTPUT); Three additional switches below the LCD provide SCROLL ESCAPE and ENTER functions |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Overvoltages from 128 to 152V are reduced by 20% (default adjustable from 120 to 144V) |
| Undervoltage Correction | Undervoltages from 88 to 102V are boosted by 8% (default adjustable from 88 to 120V) |
| Voltage Regulation Description | Corrects brownouts and overvoltages from 88 to 152V to 120V nominal (factory default) |
| Battery | |
| Battery Charge | Temperature compensated 2/4/6/8/10A selectable charging system; Battery temperature sensor cable included |
| DC System Voltage (VDC) | 48V DC |
| Expandable Runtime | Yes |
| LVC (Low Voltage Cut-Off) | UPS automatically shuts off in battery mode as battery system voltage drops to 42.5V |
| Runtime Full Load (min.) | 117 min. (1600W) |
| Runtime Half Load (min.) | 269 min. (800W) |
| Typical Battery Runtime | Above runtimes of full-load (2000VA/1600W) and half-load (1000VA/800W) with use of 48VDC 100AH battery system within a -40F(-40C)-to-131F (55C) operating environment. See manual and runtime charts for expanded runtimes with 55AH 100AH 110AH and 200AH battery configurations based on supported load and temperature |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 266 |
| AC Mode Efficiency Rating (100% Load) | >95% |
| Audible Noise | 52.4 dB maximum front-side 1 meter |
| Operating Temperature Range | -40 to 176F (-40 to 80C) |
| Relative Humidity | Up to 95% non-condensing |
| Storage Temperature Range | -40 to 176F (-40 to 80C) |
| Operating Elevation | 0-3280 ft. (0-1000 m) |
| Input | |
| Input Circuit Breakers | 30A breaker |
| Input Phase | Single-Phase |
| Maximum Input Amps | 22 |
| Nominal Input Voltage(s) Supported | 120V AC |
| Rated input current (Maximum Load) | 22A |
| Recommended Electrical Service | 120V AC |
| UPS Input Connection Description | Protected Line Neutral and Ground hardwire input terminals; Includes strain relief |
| UPS Input Connection Type | Hardwire |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Individually Controllable Load Banks | No |
| Nominal Output Voltage(s) Supported | 120V |
| Output AC Waveform (AC Mode) | Pure Sine Wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 2 |
| Output Capacity (kW) | 1.6 |
| Output Capacity (VA) | 2000 |
| Output Capacity (Watts) | 1600 |
| Output Capacity Details | Maximum output capacity is temperature dependent: 1600W (-40 to 55 C) / 1200W (55 to 75 C) and 1000W (75 to 80 C) |
| Output Circuit Breakers | 30A breaker |
| Output Receptacle Details | Protected Line Neutral and Ground hardwire output terminals; Includes strain relief |
| Output Receptacles | Hardwire |
| Output Voltage Regulation (Battery Mode) | 120V (4%) |
| Output Voltage Regulation (Line Mode) | 120V (-14% / +8%) Factory setting adjustable |
| Power Factor | 0.8 |
| Physical | |
| Cooling Method | High speed user-replaceable fan with dust filter |
| Installation Form Factors Supported with Included Accessories | 2 post 19 inch rackmount; 4 post 19 inch rackmount |
| Maximum Device Depth (cm) | 24.00 |
| Maximum Device Depth (in.) | 9.450 |
| Maximum Device Depth (mm) | 240 |
| Minimum Required Rack Depth (cm) | 25.40 |
| Minimum Required Rack Depth (inches) | 10 |
| Mounting Details | Set of two rackmount brackets support installation in 2 or 4 post racks |
| Primary Form Factor | Rackmount |
| Primary UPS Depth (mm) | 240 |
| Primary UPS Height (mm) | 133 |
| Primary UPS Width (mm) | 400 |
| Shipping Dimensions (hwd / in.) | 9.60 x 15.30 x 23.10 |
| Unit Dimensions (hwd / in.) | 5.240 x 15.750 x 9.450 |
| Unit Weight (kg) | 14.70 |
| Unit Weight (lbs.) | 32.410 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd in.) | 5.24 x 15.750 x 9.45 |
| UPS Power Module Weight (kg) | 14.70 |
| UPS Power Module Weight (lbs.) | 32.41 |
| Rack Height | 3U |
| Shipping Weight (kg) | 15.74 |
| Warranty | |
| Warranty/Returns | 30 Days |

