Tripp Lite SMART1500SLT SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS Tower Network Card Options USB DB9 8 Outlets
$684.95
Manufacturer:Eaton / Tripp Lite
Model:SMART1500SLT
Condition:New
Availability:In Stock
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SMART Series
- UPS Battery Backup
- Tripp Lite SMART1500SLT SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS Tower Network Card Options USB DB9 8 Outlets
Datasheet
The Tripp Lite SMART1500SLT 1500VA Smart UPS provides reliable battery backup and surge protection for connected equipment. Featuring automatic voltage regulation (AVR) it corrects brownouts and overvoltages without using battery power extending battery life. Its pure sine wave output ensures compatibility with sensitive electronics and active PFC power supplies.
This tower UPS offers USB and DB9 connectivity for local monitoring and control. Network management capabilities via SNMP allow remote monitoring and control making it ideal for server rooms and network closets. The SMART1500SLT delivers 900W of power offering ample runtime for critical systems during power outages.
| APPLICATIONS | |
| UPS Applications | Large Network; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality |
| COMMUNICATIONS | |
| Communications Cable | USB and DB9 cabling included |
| Communications Interface | DB9 Serial; Slot for SNMP/Web interface; USB (HID enabled) |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMART1500SLT |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS |
| High Availability UPS Features | Auto Probe Monitoring (requires WEBCARDLXE); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 145V (120V) 133V (110V) 121V (100V); All voltage setpoints 5% tolerance |
| Low Voltage Transfer to Battery Power (Setpoint) | 95V (120V) 87V (110V) 83V (100V); All voltage setpoints 5% tolerance |
| Transfer Time | 4-6 milliseconds |
| OVERVIEW | |
| UPC Code | 037332119896 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); NOM (Mexico); UL 1778 |
| Product Compliance | RoHS; FCC Part 15 Class A (USA) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 690 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| UPS Dataline Suppression | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch |
| Audible Alarm | Audible alarm indicates power failure and overload conditions |
| LED Indicators | Status LEDs indicate line power battery power AVR overload and replace battery status - with a 3-LED level meter for load and battery charge level |
| Site Wiring Fault Indication | Rear panel site wiring fault LED |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Voltage reduction of 12% applies when input is 127 to 145 (120v) 116 to 133 (110v) 111 to 121 (100v); All voltage setpoints 5% tolerance |
| Undervoltage Correction | Voltage boost of 14% applies when input is 95 to 108 (120v) 87 to 99 (110v) 83 to 90 (100v); All voltage setpoints5% tolerance |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 95 to 145 (120v) 87 to 133 (110v) 83 to 121 (100v) |
| Battery | |
| Battery Access | Battery access door |
| Battery Recharge Rate (Included Batteries) | Less than 6 hours from 10% to 80% (typical full load discharge) |
| Battery Replacement Description | Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 36 |
| Expandable Runtime | No |
| Runtime Full Load (min.) | 8 min. (900W) |
| Runtime Half Load (min.) | 20 min. (450W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 148 |
| AC Mode Efficiency Rating (100% Load) | 95% |
| Audible Noise | Audible Noise < 50 dBA at Front Side 1 Meter |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 500 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Operating Elevation | 0-6562 ft. (0-2000 m) |
| Input | |
| Input Circuit Breakers | 15A |
| Input Phase | Single-Phase |
| Maximum Input Amps | 10 |
| Nominal Input Voltage(s) Supported | 100V AC; 110V AC; 120V AC |
| Rated input current (Maximum Load) | 10.1A (100V) 9.3A (110V) 8.6A (120V) |
| Recommended Electrical Service | 15A 120V |
| Total Harmonic Distortion | 0.03 |
| UPS Input Connection Type | 5-15P |
| UPS Input Cord Length (ft.) | 6 |
| UPS Input Cord Length (m) | 1.8 |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Automatic frequency selection. Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. |
| Individually Controllable Load Banks | No |
| Nominal Output Voltage(s) Supported | 100V; 110V; 120V |
| Nominal Voltage Details | 120V sinusoidal in line mode and 120V sinusoidal in battery mode |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 1.5 |
| Output Capacity (kW) | 0.9 |
| Output Capacity (VA) | 1500 |
| Output Capacity (Watts) | 900 |
| Output Capacity Details | 7.5A @ 120V (default) 8.2A @ 110V 9A @ 100V. 125% @ 10 minutes 110% +/- 10% @ 5 seconds |
| Output Receptacles | (8) 5-15R |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Output Voltage Regulation (Line Mode) | -13% + 15% |
| Power Factor | 0.63 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | Tower |
| Primary Form Factor | Tower |
| Primary UPS Depth (mm) | 335 |
| Primary UPS Height (mm) | 259 |
| Primary UPS Width (mm) | 173 |
| Shipping Dimensions (hwd / cm) | 35.31 x 24.64 x 44.70 |
| Shipping Dimensions (hwd / in.) | 13.90 x 9.70 x 17.60 |
| Unit Dimensions (hwd / in.) | 10.250 x 6.750 x 13.250 |
| Unit Weight (kg) | 20.41 |
| Unit Weight (lbs.) | 45.0000 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd cm) | 25.91 x 17.27 x 33.53 |
| UPS Power Module Dimensions (hwd in.) | 10.2 x 6.8 x 13.2 |
| UPS Power Module Weight (kg) | 20.41 |
| UPS Power Module Weight (lbs.) | 45 |
| Shipping Weight (kg) | 21.00 |
| Shipping Weight (lbs.) | 46.30 |
| Warranty | |
| Warranty/Returns | 30 Days |