Tripp Lite SM2200RMXL2UTAA TAA SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS 2U Extended Run Network Card Options LCD USB DB9 UPS Battery Backup

Tripp Lite SM2200RMXL2UTAA TAA SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS 2U Extended Run Network Card Options LCD USB DB9

$1,428.78
Manufacturer:Eaton / Tripp Lite
Model:SM2200RMXL2UTAA
Condition:New
Availability:In Stock
The Tripp Lite Smart2200RMXL2UTAA 2200VA/1600W UPS offers extended runtime AVR and USB/DB9 connectivity in a 2U rackmount form factor. Ideal for protecting critical equipment in data centers and network closets.
Datasheet

The Tripp Lite Smart2200RMXL2UTAA 2200VA/1920W UPS System is a smart rackmount solution designed to safeguard mission-critical servers networking equipment and telecommunications systems from power disruptions. This 2U UPS provides automatic voltage regulation (AVR) to correct brownouts and overvoltages without using battery power extending battery life. It also offers extended runtime capabilities for maximum uptime during prolonged outages.

Featuring both USB and DB9 serial connectivity the Smart2200RMXL2UTAA allows for seamless integration with various operating systems and power management software. TAA compliant and suitable for government and GSA applications this UPS ensures reliable power protection in demanding environments.

APPLICATIONS
UPS Applications Large Network
COMMUNICATIONS
Communications Cable USB and DB9 cabling included
Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
Network Management Card Description Network management card optional
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
Network UPS Tools (NUT) Compatibility NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
PowerAlert Software For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert
WatchDog Compatibility Supports Watchdog application OS and hard-reboot restart options for remote applications
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number SM2200RMXL2UTAA
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
Grounding Details Back panel grounding lug
High Availability UPS Features Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 145
Low Voltage Transfer to Battery Power (Setpoint) 83
Transfer Time 5 milliseconds (line to battery mode); 1 millisecond (battery to line mode)
OVERVIEW
UPC Code 037332152800
UPS Type Line-Interactive
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); UL 1778
Product Compliance RoHS; FCC Part 15 Class A (USA); Trade Agreements Act (TAA)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 570
AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
USER INTERFACE ALERTS & CONTROLS
Alarm Cancel Operation Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Audible Alarm Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
Switches Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
VOLTAGE REGULATION
Overvoltage Correction Voltage reduction of 12% applies when input is between 127 and 145
Severe Undervoltage Correction Voltage boost of 24% applies when input voltage is between 83 and 95
Undervoltage Correction Voltage boost of 12% applies when input voltage is between 96 and 108
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
Battery
Battery Access Front panel battery access door
Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90%
Battery Replacement Description Hot-swappable user replaceable batteries
DC System Voltage (VDC) 48
Expandable Runtime Yes
Runtime Full Load (min.) 4.5 min. (1920W)
Runtime Half Load (min.) 12 min. (960W)
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Mode BTU / Hr. (Full Load) 306
Audible Noise 45 dBA maximum front side 1m
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load 1157
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 0-95% non-condensing
Storage Temperature Range 5 to 122F (-15 to 50C)
Input
Input Phase Single-Phase
Maximum Input Amps 16
Nominal Input Voltage(s) Supported 120V AC
Rated input current (Maximum Load) 16A (120V)
Recommended Electrical Service 20A 120V
UPS Input Connection Type 5-20P
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3.1
Output
Frequency Compatibility 60 Hz
Individually Controllable Load Banks Yes
Load Management Receptacles Two switched single outlet load banks (1 5-15/20R & 1 5-15R)
Nominal Output Voltage(s) Supported 110V; 115V; 120V
Nominal Voltage Details 120v nominal output in battery mode
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Output Capacity (kVA) 2.2
Output Capacity (kW) 1.92
Output Capacity (VA) 2200
Output Capacity (Watts) 1920
Output Capacity Details Output is reduced to 1600 watts maximum when used with external battery packs
Output Receptacles (4) 5-15R; (4) 5-15/20R
Output Voltage Regulation (Battery Mode) +/- 5%
Output Voltage Regulation (Line Mode) -14% +6%
Power Factor 0.87
Physical
Cooling Method Fan
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Minimum Required Rack Depth (cm) 55.88
Minimum Required Rack Depth (inches) 22
Minimum Required Rack Depth with External Battery Pack (cm) 66
Minimum Required Rack Depth with External Battery Pack (in.) 26
Minimum Required Rack Depth without External Battery Pack (cm) 62
Minimum Required Rack Depth without External Battery Pack (in.) 24.5
Mounting Details Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Primary Form Factor Rackmount
Primary UPS Depth (mm) 490
Primary UPS Height (mm) 88
Primary UPS Width (mm) 440
Shipping Dimensions (hwd / cm) 22.35 x 60.96 x 53.09
Shipping Dimensions (hwd / in.) 8.80 x 24.00 x 20.90
Unit Weight (kg) 26.13
Unit Weight (lbs.) 57.600
UPS Housing Material Steel
UPS Power Module Dimensions (hwd cm) 8.79 x 43.99 x 49.00
UPS Power Module Dimensions (hwd in.) 3.46 x 17.32 x 19.29
UPS Power Module Weight (kg) 26.13
UPS Power Module Weight (lbs.) 57.6
Rack Height 2U
Shipping Weight (kg) 35.38
Shipping Weight (lbs.) 78.00
Warranty