Tripp Lite SM2200RMDVTAA TAA SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS 3U 120/230V input Network Card Options USB DB9
$2,144.34
Manufacturer:Eaton / Tripp Lite
Model:SM2200RMDVTAA
Condition:New
Availability:Out Of Stock
Condition:New
Availability:Out Of Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SmartPro SM Series
- UPS Battery Backup
- Tripp Lite SM2200RMDVTAA TAA SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS 3U 120/230V input Network Card Options USB DB9
Datasheet
The Tripp Lite SM2200RMDVTAA 2200VA Smart UPS safeguards your valuable electronics with 1920W of pure sine wave battery backup power during outages and surges. This 3U rackmount unit features automatic voltage regulation (AVR) to correct brownouts and overvoltages without using battery power.
USB connectivity allows for seamless integration with network management systems enabling remote monitoring and control. TAA compliant for government and GSA procurement. Ideal for protecting servers networking equipment and other sensitive devices.
| APPLICATIONS | |
| UPS Applications | Large Network |
| COMMUNICATIONS | |
| Communications Cable | USB and DB9 cabling included |
| Communications Interface | DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| Network UPS Tools (NUT) Compatibility | NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SM2200RMDVTAA |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
| High Availability UPS Features | Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 148 (120V) 286 (230V) |
| Low Voltage Transfer to Battery Power (Setpoint) | 89 (120V) 170 (230V) |
| Transfer Time | 2-4 milliseconds |
| OVERVIEW | |
| UPC Code | 037332156310 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); UL 1778 |
| Product Compliance | RoHS; FCC Part 15 Class A (USA); Trade Agreements Act (TAA) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 340 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced alarm will re-sound to indicate low-battery status |
| Audible Alarm | Audible alarm indicates power-failure overload and low-battery conditions |
| LED Indicators | 5 LEDs indicate line power battery power overload voltage regulation and battery low/replace status |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Voltage reduction of 12% applies when input is between 127 and 148 (120V) |
| Undervoltage Correction | Voltage boost of 12% applies when input voltage is between 96 and 108 (120V) |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains 120v line power output with input range of 89 to 148 or 170 to 286 |
| Battery | |
| Battery Access | Front panel battery access door |
| Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% (internal batteries) |
| Battery Replacement Description | Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 48 |
| Expandable Runtime | Yes |
| Runtime Full Load (min.) | 12 min. (1920W) |
| Runtime Half Load (min.) | 30 min. (960W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 347 |
| AC Mode Efficiency Rating (100% Load) | 95% |
| Audible Noise | 45 dBA maximum front side 1m |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 894 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Input | |
| Input Circuit Breakers | 20A |
| Input Phase | Single-Phase |
| Maximum Input Amps | 16 |
| Nominal Input Voltage(s) Supported | 120V AC; 230V AC |
| Rated input current (Maximum Load) | 16A (120V) 10A (230V) |
| UPS Input Connection Description | C20 inlet and 5 compatible plugsets (5-20P Schuko CEE7 EU1-16P British BS1363 Italian CEI 23-16) |
| UPS Input Connection Type | C20 inlet |
| UPS Input Cord Length (ft.) | 6 |
| UPS Input Cord Length (m) | 1.8 |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Automatic frequency selection |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | Two switchable single-outlet 5-15R load banks |
| Nominal Output Voltage(s) Supported | 120V |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 2.2 |
| Output Capacity (kW) | 1.92 |
| Output Capacity (VA) | 2200 |
| Output Capacity (Watts) | 1920 |
| Output Receptacles | (4) 5-15R; (4) 5-15/20R |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Power Factor | 0.87 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount |
| Minimum Required Rack Depth (cm) | 73.66 |
| Minimum Required Rack Depth (inches) | 29 |
| Minimum Required Rack Depth with External Battery Pack (cm) | 82 |
| Minimum Required Rack Depth with External Battery Pack (in.) | 32.25 |
| Minimum Required Rack Depth without External Battery Pack (cm) | 77 |
| Minimum Required Rack Depth without External Battery Pack (in.) | 30.25 |
| Mounting Details | Complete installation accessories available for 2 post 4 post and tower installation |
| Primary Form Factor | Rackmount |
| Primary UPS Depth (mm) | 641 |
| Primary UPS Height (mm) | 133 |
| Primary UPS Width (mm) | 445 |
| Shipping Dimensions (hwd / cm) | 30.48 x 76.20 x 76.20 |
| Shipping Dimensions (hwd / in.) | 12.00 x 30.00 x 30.00 |
| Unit Dimensions (hwd / in.) | 5.250 x 17.750 x 25.250 |
| Unit Weight (kg) | 47.29 |
| Unit Weight (lbs.) | 104.2500 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd cm) | 13.34 x 44.45 x 64.14 |
| UPS Power Module Dimensions (hwd in.) | 5.25 x 17.5 x 25.25 |
| UPS Power Module Weight (kg) | 47.29 |
| UPS Power Module Weight (lbs.) | 104.25 |
| Rack Height | 3U |
| Shipping Weight (kg) | 72.57 |
| Shipping Weight (lbs.) | 160.00 |
| Warranty | |
| Warranty/Returns | 30 Days |