The Tripp Lite SM1500RMXL2UTAA SmartOnline 1500VA/1350W UPS System offers double-conversion backup power surge suppression and voltage regulation in a compact 2U rack/tower form factor. Ideal for protecting servers networking equipment and other sensitive electronics it ensures continuous operation during power failures while safeguarding against damaging surges and voltage fluctuations. It features USB and DB9 connectivity for monitoring and control.
This TAA-compliant UPS provides automatic voltage regulation (AVR) to correct minor power fluctuations without switching to battery power extending battery life. The SM1500RMXL2UTAA is a reliable solution for maintaining business continuity and protecting valuable equipment in demanding IT environments.
| APPLICATIONS | |
| UPS Applications | Large Network; High-End Desktop/Small Network |
| COMMUNICATIONS | |
| Communications Cable | USB and DB9 cabling included |
| Communications Interface | DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| Network UPS Tools (NUT) Compatibility | NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SM1500RMXL2UTAA |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
| Grounding Details | Back panel grounding lug |
| High Availability UPS Features | Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 145 |
| Low Voltage Transfer to Battery Power (Setpoint) | 83 |
| Transfer Time | 4 milliseconds (AC to battery mode) 1 millisecond (Battery to AC mode) |
| OVERVIEW | |
| UPC Code | 037332152831 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); UL 1778 |
| Product Compliance | RoHS; FCC Part 15 Class B (USA); Trade Agreements Act (TAA) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 570 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
| Audible Alarm | Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions |
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
| Switches | 3 pushbutton switches control OFF / ON power status MODE selection and MUTE / ENTER control functions |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Input voltages between 127 and 145 are reduced by 12% |
| Severe Undervoltage Correction | Input voltages between 83 and 94 are boosted by 24% |
| Undervoltage Correction | Input voltages between 95 and 108 are boosted by 12% |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145 |
| Battery | |
| Battery Access | Front panel battery access door |
| Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% |
| Battery Replacement Description | Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 36 |
| Expandable Runtime | Yes |
| Runtime Full Load (min.) | 4.9 min. (1350W) |
| Runtime Half Load (min.) | 14 min. (675W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 237 |
| AC Mode Efficiency Rating (100% Load) | 95% |
| Audible Noise | 45 dBA maximum front side 1m |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 751 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Input | |
| Input Circuit Breakers | 15A |
| Input Phase | Single-Phase |
| Maximum Input Amps | 12 |
| Nominal Input Voltage(s) Supported | 120V AC |
| Rated input current (Maximum Load) | 12A |
| Recommended Electrical Service | 15A 120V |
| UPS Input Connection Type | 5-15P |
| UPS Input Cord Length (ft.) | 10 |
| UPS Input Cord Length (m) | 3.1 |
| Output | |
| Frequency Compatibility | 60 Hz |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | Two switchable two-outlet 5-15R load banks |
| Nominal Output Voltage(s) Supported | 110V; 115V; 120V |
| Nominal Voltage Details | 120v nominal output in battery mode |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 1.5 |
| Output Capacity (kW) | 1.35 |
| Output Capacity (VA) | 1500 |
| Output Capacity (Watts) | 1350 |
| Output Capacity Details | Output is reduced to 1200 watts maximum when used with external battery packs |
| Output Receptacles | (8) 5-15R |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Output Voltage Regulation (Line Mode) | -14% +6% |
| Power Factor | 0.9 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount |
| Minimum Required Rack Depth (cm) | 43.18 |
| Minimum Required Rack Depth (inches) | 17 |
| Minimum Required Rack Depth with External Battery Pack (cm) | 51 |
| Minimum Required Rack Depth with External Battery Pack (in.) | 20 |
| Minimum Required Rack Depth without External Battery Pack (cm) | 42 |
| Minimum Required Rack Depth without External Battery Pack (in.) | 16.5 |
| Mounting Details | Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm) |
| Primary Form Factor | Rackmount |
| Primary UPS Depth (mm) | 342 |
| Primary UPS Height (mm) | 88 |
| Primary UPS Width (mm) | 439 |
| Shipping Dimensions (hwd / cm) | 22.35 x 58.42 x 49.02 |
| Shipping Dimensions (hwd / in.) | 8.80 x 23.00 x 19.30 |
| Unit Weight (kg) | 21.09 |
| Unit Weight (lbs.) | 46.5000 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd cm) | 8.76 x 43.94 x 34.16 |
| UPS Power Module Dimensions (hwd in.) | 3.45 x 17.3 x 13.45 |
| UPS Power Module Weight (kg) | 21.09 |
| UPS Power Module Weight (lbs.) | 46.5 |
| Rack Height | 2U |
| Shipping Weight (kg) | 26.04 |
| Shipping Weight (lbs.) | 57.40 |
| Warranty | |
| Warranty/Returns | 30 Days |