Tripp Lite PDUMVR30HVNETLX Eaton 5.5kW Single-Phase Switched PDU Outlet Monitoring 208/230V Outlets (20 C13 & 4 C19) 0U LX Interface TAA PDU Series

Tripp Lite PDUMVR30HVNETLX Eaton 5.5kW Single-Phase Switched PDU Outlet Monitoring 208/230V Outlets (20 C13 & 4 C19) 0U LX Interface TAA

$1,394.53
Manufacturer:Eaton / Tripp Lite
Model:PDUMVR30HVNETLX
Condition:New
Availability:In Stock
The Tripp Lite PDUMVR30HVNETLX switched PDU provides 208/240V 30A power distribution with (4) C19 and (20) C13 outlets in a 0U horizontal LX platform design. Ideal for rackmount applications.
Datasheet

The Tripp Lite PDUMVR30HVNETLX is a switched PDU designed for high-power density applications. Providing 208/240V 30A distribution this unit features (4) C19 and (20) C13 outlets offering versatile connectivity for a variety of IT equipment. Its 0U horizontal LX platform design optimizes rack space and simplifies cable management.

This TAA-compliant PDU offers reliable power distribution in a robust rack-mountable form factor. The switched outlets allow for individual control of connected devices enhancing energy efficiency and facilitating remote management capabilities. Ideal for data centers server rooms and network closets.

COMMUNICATIONS
Communications Cable RJ45-to-DB9 configuration/console Access cable
Network Compatibility 10 Mbps; 100 Mbps (Fast Ethernet)
Network Monitoring Port RJ45 Network port RJ45 Serial Config/Console Access port; USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.
PowerAlert Software LX Platform Interface: PowerAlert Device Manager
SNMP Compatibility Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface telnet SSH CLI and SNMP management systems
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number PDUMVR30HVNETLX
FEATURES & SPECIFICATIONS
High Availability PDU Features Auto Probe Monitoring and Reboot (included); Auto Load Shedding
OVERVIEW
PDU Type Switched
UPC Code 037332202840
STANDARDS & COMPLIANCE
Product Certifications NOM (Mexico); UL 60950-1
Product Compliance RoHS; FCC Part 15 Class A (USA); Trade Agreements Act (TAA)
SURGE / NOISE SUPPRESSION
Automatic Shut-Off No
USER INTERFACE ALERTS & CONTROLS
Current Measurement Accuracy (Amps) +/-1%
Front Panel LCD Display Digital display reports load level in amps for LOAD BANK 1 (Outlets 1-12) LOAD BANK 2 (Outlets 13-24) LOAD BANKS 1&2 COMBINED (Outlets 1-24) and each individual output receptacle; Digital display can also be used to scroll the configured IP address
LED Indicators BANK 1 and BANK 2 LEDs verify which load bank the digital current display is reporting (Bank 1 Bank 2 or Banks 1&2 Combined); BANK 1 or BANK 2 LED will flash when the digital display is reporting output current for one of the outlets in that load bank; 24 additional LEDs one near each output receptacle will light continuously to verify power on/off status and flash to indicate that the digital display is reporting output current for just that individual receptacle.Network Link/Activity Status LED (Yellow) Network Speed LED (Green); LX Platform status LED (Green)
Power Measurement Accuracy (Watts) +/-1%
Switches SELECT OUTLET and SELECT BANK switches advance the LCD screen and associated LED to display power consumption for individual output receptacles and output load banks; Press and hold the SELECT BANK button for 4 seconds to rotate the digital display 90 degrees for overhead power input; Press and hold the SELECT OUTLET button for 4 seconds to scroll the configured IP address. LX Platform Interface: Recessed reset switch for interface reboot and factory reset
Voltage Measurement Accuracy (Volts) +/-1%
Details
Category Power Distribution Units (PDUs)
Environmental
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 5% to 95% non-condensing
Storage Temperature Range -22 to 122F (-30 to 50C)
Operating Elevation 0-10000 ft. (0-3000 m)
Input
Input Cord Length (ft.) 10
Input Cord Length (m) 3.05
Input Phase Single-Phase
Maximum Input Amps 24
Maximum Input Amps Details Agency de-rated to 24A continuous
PDU Input Voltage 208; 230
PDU Plug Type NEMA L6-30P
Recommended Electrical Service Single-phase 30A 208/230V service
Output
Customized Load Management Receptacles Each outlet is individually controllable via remote interface
Frequency Compatibility 50 / 60 Hz
Output Capacity Details 5.5kW (230V) 5kW (208V) total capacity / 30A max (Agency de-rated to 24A) 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet
Output Nominal Voltage 208/230V
Output Receptacles (20) C13; (4) C19
Overload Protection Two 20A breakers protect 12 outlets each
Physical
PDU Form Factor Vertical (0U)
Shipping Dimensions (hwd / cm) 13.72 x 17.27 x 193.29
Shipping Dimensions (hwd / in.) 5.40 x 6.80 x 76.10
Unit Dimensions (hwd / cm) 178 x 5.6 x 6.6
Unit Dimensions (hwd / in.) 70.000 x 2.200 x 2.600
Unit Weight (kg) 5.44
Unit Weight (lbs.) 12
Form Factors Supported 0U vertical rackmount; includes rackmount brackets. Supports toolless mounting in button-mount compatible racks
Material Of Construction Metal
Rack Height 0U
Shipping Weight (kg) 7.48
Shipping Weight (lbs.) 16.50
Warranty
Warranty/Returns 30 Days