Tripp Lite PDUB151U 100-125V 12A Single-Phase Hot-Swap PDU with Manual Bypass - 6 NEMA 5-15R Outlets 2 5-15P Inputs 1U Rack/Wall PDU Series

Tripp Lite PDUB151U 100-125V 12A Single-Phase Hot-Swap PDU with Manual Bypass - 6 NEMA 5-15R Outlets 2 5-15P Inputs 1U Rack/Wall

$188.99
Manufacturer:Eaton / Tripp Lite
Model:PDUB151U
Condition:New
Availability:In Stock
The Tripp Lite PDUB151U offers hot-swappable manual bypass power distribution with six 5-15R outlets and dual 5-15P inputs in a compact 1U rack-mount design. Ideal for critical equipment needing continuous power.
Datasheet

The Tripp Lite PDUB151U Hot-Swap PDU with Manual Bypass ensures continuous power to connected equipment. Featuring six 5-15R outlets and dual 5-15P inputs this 15A PDU provides redundant power capabilities in a space-saving 1U rack-mount form factor.

The manual bypass switch allows for seamless transfer between power sources minimizing downtime during maintenance or power failures. Ideal for critical applications in data centers network closets and server rooms.

DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number PDUB151U
FEATURES & SPECIFICATIONS
High Availability PDU Features Manual Hot-Swap Bypass
OVERVIEW
PDU Type Hot-Swap
UPC Code 037332253071
STANDARDS & COMPLIANCE
Product Certifications CAN/CSA-C22.2 No. 62368-1 (Canada); NOM (Mexico); UL 62368-1
Product Compliance RoHS
SURGE / NOISE SUPPRESSION
Automatic Shut-Off No
USER INTERFACE ALERTS & CONTROLS
LED Indicators Front panel LEDs report UTILITY Input Power ON (green) BYPASS-MODE Switch Setting (yellow) MASTER Outlet Power ON (green) CONTROLLABLE GROUP Outlets Power ON (green)
Switches 2 position Manual Transfer switch offers Break-Before-Make transfer between UPS and Utility operating modes with less than 8 milliseconds (typical) transfer time; Additional switch offers ENABLE/DISABLE control of the ECO Power-Saving feature
Details
Category Power Distribution Units (PDUs)
Environmental
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 5% to 95% non-condensing
Storage Temperature Range -22 to 122F (-30 to 50C)
Operating Elevation 0-10000 ft. (0-3000 m)
Input
Input Connection Type (2) NEMA 5-15P
Input Cord Details Utility input cable (10 ft / 3m) / UPS input cable (4 ft / 1.2m)
Input Cord Length (ft.) 10
Input Cord Length (m) 3.05
Input Phase Single-Phase
Maximum Input Amps 12
Maximum Input Amps Details Agency de-rated to 12A continuous
PDU Input Voltage 100; 120; 125
PDU Plug Type (2) NEMA 5-15P
Recommended Electrical Service Works with most 100-125V UPS systems up to 1500VA
Output
Frequency Compatibility 50 / 60 Hz
Output Capacity Details 1.52kW (125V) 1.44kW (120V) 1.2kW (100V) / 15A total capacity (Agency de-rated to 12A); 12A max per 5-15R outlet
Output Nominal Voltage 100-125V
Output Receptacle Details Set of 6 output receptacles are arranged in two groups to support the optional ECO Power-Saving feature; One MASTER-outlet provides optional current-sense capability that when enabled automatically powers off the bank of 5 CONTROLLABLE GROUP-outlets when the device connected to the MASTER-outlet is powered off or enters a low power sleep mode consuming 20W or less (5W)
Output Receptacles (6) 5-15R
Physical
PDU Form Factor Horizontal (1U)
Shipping Dimensions (hwd / in.) 5.20 x 8.00 x 21.30
Unit Dimensions (hwd / cm) 4.39 x 43.79 x 10.01
Unit Dimensions (hwd / in.) 1.730 x 17.240 x 3.940
Unit Weight (kg) 2.36
Unit Weight (lbs.) 5.2
Form Factors Supported Includes installation accessories for wall mount and 1U horizontal rackmount installation in 2 or 4 post equipment racks
Material Of Construction Metal
Rack Height 1U
Shipping Weight (kg) 3.08
Warranty
Warranty/Returns 30 Days