Tripp Lite PDU12IEC 1.9-3.8kW Single-Phase 120240V Basic PDU 14 Outlets (12 C13 & 2 C19) C20 16A Input 1U Rack-Mount PDU Series

Tripp Lite PDU12IEC 1.9-3.8kW Single-Phase 120240V Basic PDU 14 Outlets (12 C13 & 2 C19) C20 16A Input 1U Rack-Mount

$206.60
Manufacturer:Eaton / Tripp Lite
Model:PDU12IEC
Condition:New
Availability:In Stock
The Tripp Lite PDU12IEC provides 12 C13 & 2 C19 outlets in 1U distributing 100-240V power (16A 3.8kW) for rack-mounted equipment.
Datasheet

The Tripp Lite PDU12IEC Basic PDU distributes reliable 100-240V power to rack-mounted equipment. This 1U horizontal PDU features 12 C13 and 2 C19 outlets supporting a total of 16A and 3.8kW.

Ideal for high-density data centers and network closets the PDU12IEC simplifies power distribution within a rack ensuring connected devices receive consistent and dependable power. Its robust construction and versatile voltage range make it suitable for diverse IT environments.

DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number PDU12IEC
FEATURES & SPECIFICATIONS
Grounding Grounding lug
OVERVIEW
PDU Type Basic
UPC Code 037332116253
STANDARDS & COMPLIANCE
Product Certifications RETIE (Colombia); CAN/CSA-C22.2 No. 60950-1 (Canada); NOM (Mexico); UL 60950-1
Product Compliance RoHS; CE (Europe)
SURGE / NOISE SUPPRESSION
Automatic Shut-Off No
USER INTERFACE ALERTS & CONTROLS
Switches No power switch
Details
Category Power Distribution Units (PDUs)
Environmental
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 5% to 95% non-condensing
Storage Temperature Range -22 to 122F (-30 to 50C)
Operating Elevation 0-10000 ft. (0-3000 m)
Input
Input Connection Type IEC-320 C20
Input Cord Details C20 inlet accepts user supplied input cable with C19 output connection
Input Cord Length (m) 0.00
Input Phase Single-Phase
Maximum Input Amps 16
Maximum Input Amps Details Agency derated to 16A continuous (North America only)
PDU Input Voltage 120; 125; 127; 200; 208; 220; 230; 240
PDU Plug Type IEC-320 C20
Recommended Electrical Service Single-phase 16/20A 120-240V service
Output
Frequency Compatibility 50 / 60 Hz
Output Capacity Details 3.84kW (240V) 3.68kW (230V) 3.52kW (220V) 3.33kW (208V) 3.2kW (200V) 2.03kW (127V) 1.92kW (120V) / 16A total capacity; 16A max per C19 outlet; 12A (10A CE) max per C13 outlet
Output Nominal Voltage 120-240V
Output Receptacles (12) C13; (2) C19
Overload Protection 16A circuit breaker
Physical
Minimum Required Rack Depth (cm) 19.81
Minimum Required Rack Depth (inches) 7.8
Outlets Measurement (Center to Center) Distance between Front (C13) outlets = 28.75mm; Distance between Rear (C19) outlets = 55mm; Distance between Rear (C13) outelts = 28.75mm
PDU Form Factor Horizontal (1U)
Shipping Dimensions (hwd / cm) 5.33 x 52.32 x 23.62
Shipping Dimensions (hwd / in.) 2.10 x 20.60 x 9.30
Unit Dimensions (hwd / cm) 44 x 445 x 108
Unit Dimensions (hwd / in.) 1.750 x 19.000 x 4.250
Unit Weight (kg) 1.45
Unit Weight (lbs.) 3.20
Form Factors Supported 1U rackmount 0U vertical rackmount wall-mount and undercounter installation supported
Material Of Construction Metal
Rack Height 1U
Shipping Weight (kg) 1.68
Shipping Weight (lbs.) 3.70
Warranty
Warranty/Returns 30 Days