Tripp Lite IS600HGDV Isolator Series Dual-Voltage 115/230V 600W 60601-1 Medical-Grade Isolation Transformer C14 Inlet 6 C13 Outlets Isobar Series

Tripp Lite IS600HGDV Isolator Series Dual-Voltage 115/230V 600W 60601-1 Medical-Grade Isolation Transformer C14 Inlet 6 C13 Outlets

$799.46
Manufacturer:Eaton / Tripp Lite
Model:IS600HGDV
Condition:New
Availability:In Stock
The Tripp Lite IS600HGDV Isolation Transformer provides 600W of medical-grade power isolation with dual 115/230V output. Features a C14 inlet and six C13 outlets.
Datasheet

The Tripp Lite IS600HGDV Isolation Transformer is a medical-grade power solution designed for sensitive equipment in hospitals and healthcare facilities. Providing 600 watts of isolated power it protects connected devices from electrical noise and voltage fluctuations. The dual-voltage configuration (115/230V) offers flexibility for various applications.

Featuring a C14 inlet for easy connection to a UPS or wall outlet the IS600HGDV offers six C13 outlets to power multiple devices. This transformer ensures reliable and safe operation of critical medical equipment.

DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number IS600HGDV
FEATURES & SPECIFICATIONS
Over Current Protection 2 x 6A @ 115V and 2 x 3.15A at 230V ( Both Fuses included with Product as Accesories)
OPERATION
System Type Selections Input Voltage equals Output Voltage OR 120V input equals 230V output OR 230V Input equals 120V output -(Selectable when installing Fuses) Input Frequency always equals Output Frequency
OVERVIEW
Efficiency 96%
Nominal Voltage / Frequency 115/230 VAC 50/60 HZ (Voltage Selected by Input Power Module Fuse Installation
Transformer Type Medical Grade Low Impedence Toroid- Line Isolation (Pass Through or Step UP or Step Down)
UPC Code 037332200006
VA / Watt Capacity 600
STANDARDS & COMPLIANCE
Product Certifications IEC 60601-1; CAN/CSA-C22.2 No. 60601-1 (Canada); NOM (Mexico)
Product Compliance RoHS; CE (Europe)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 240
IEEE587 Cat. A Ringwave Let-Through Reduced to 0.5v Common Mode
Noise Suppression Rating 35-65 dB
Details
Category Isolation Transformers
Environmental
Operating Humidity Range 5% to 95% RH (Non-Condensing)
Operating Temperature Range 32 to 104F (0 to 40C) Intended Application is in a controlled environment at approx. 77F.
Storage Temperature Range 5 to 122F (-15 to 50C)
Operating Elevation 0-10000 ft. (0-3000 m)
Input
Maximum Surge Amps 70A
Nominal Input Voltage Description 115/230 VAC (Selected by Input Power Module Fuse Installation) Operating Input Voltage Range 100-125Vac or 200-250VAC
Power Input Receptacle IEC-320-C14
THDi Less than 1%
Input Current 6A @ 115V / 3.15A @ 230V
Input Frequency 50/60HZ
Isolation
Leakage Current Max AC Leakage Current 50 (uA)
Output Isolation Transformer Toroid with AC output Floating with Respect to Earth Ground. Includes POAG and Earth Ground Stud.
Output
Frequency Compatibility 50 / 60 Hz
Output (Watts) 600
Output Nominal Voltage 115V/230V (Selected by Output Switch) Can also be step up or step down Selected when Installing Fuses.
Output Receptacle Details IEC320-C13
Output Receptacles (6) C13
Output Voltage Regulation (Line Mode) 4.1%
Physical
Cooling Method Convection
Shipping Dimensions (hwd / cm) 23.01 x 32.51 x 37.01
Shipping Dimensions (hwd / in.) 9.06 x 12.80 x 14.57
Unit Dimensions (hwd / cm) 11 x 20 x 25
Unit Dimensions (hwd / in.) 4.330 x 7.870 x 9.840
Unit Weight (kg) 9.24
Unit Weight (lbs.) 20.38
Color White
Material Of Construction Metal (Cabinet)
Shipping Weight (kg) 10.08
Shipping Weight (lbs.) 22.22
Warranty