Tripp Lite IS1800HGDV Isolator Series Dual-Voltage 115/230V 1800W 60601-1 Medical-Grade Isolation Transformer C20 Inlet 8 C13 Outlets
$1,617.38
Manufacturer:Eaton / Tripp Lite
Model:IS1800HGDV
Condition:New
Availability:In Stock
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- Isolation Transformers
- IS Series
- Tripp Lite IS1800HGDV Isolator Series Dual-Voltage 115/230V 1800W 60601-1 Medical-Grade Isolation Transformer C20 Inlet 8 C13 Outlets
Datasheet
The Tripp Lite IS1800HGDV Isolator Series Dual-Voltage Isolation Transformer provides 1800W of clean isolated power for crucial medical equipment. Designed to meet the stringent 60601-1 medical safety standards this transformer ensures patient and equipment safety in hospital environments. It features a C20 inlet for easy connection to a power source.
With its dual 115/230V voltage configuration and eight C13 outlets the IS1800HGDV powers multiple devices simultaneously. This reliable transformer offers enhanced protection against electrical noise and surges maintaining the performance integrity of connected medical equipment.
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | IS1800HGDV |
| FEATURES & SPECIFICATIONS | |
| Over Current Protection | 2 x 15A @ 115V and 2 x 8A at 230V ( Both Fuses included with Product as Accesories) |
| OPERATION | |
| System Type Selections | Input Voltage equals Output Voltage OR 120V input equals 230V output OR 230V Input equals 120V output -(Selectable when installing Fuses) Input Frequency always equals Output Frequency |
| OVERVIEW | |
| Efficiency | 96% |
| Nominal Voltage / Frequency | 115/230 VAC 50/60 HZ (Voltage Selected by Input Power Module Fuse Installation |
| Transformer Type | Medical Grade Low Impedence Toroid- Line Isolation (Pass Through or Step UP or Step Down) |
| UPC Code | 037332200037 |
| VA / Watt Capacity | 1800 |
| STANDARDS & COMPLIANCE | |
| Product Certifications | IEC 60601-1; CAN/CSA-C22.2 No. 60601-1 (Canada); NOM (Mexico) |
| Product Compliance | RoHS; CE (Europe) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 240 |
| IEEE587 Cat. A Ringwave Let-Through | Reduced to 0.5v Common Mode |
| Noise Suppression Rating | 35-65 dB |
| Details | |
| Category | Isolation Transformers |
| Environmental | |
| Operating Humidity Range | 5% to 95% RH (Non-Condensing) |
| Operating Temperature Range | 32 to 104F (0 to 40C) Intended Application is in a controlled environment at approx. 77F. |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Operating Elevation | 0-10000 ft. (0-3000 m) |
| Input | |
| Maximum Surge Amps | 100A |
| Nominal Input Voltage Description | 115/230 VAC (Selected by Input Power Module Fuse Installation) Operating Input Voltage Range 100-125Vac or 200-250VAC |
| Power Input Receptacle | IEC-320-C20 |
| THDi | Less than 1% |
| Input Current | 15A @ 115V / 8A @ 230V |
| Input Frequency | 50/60HZ |
| Isolation | |
| Leakage Current | Max AC Leakage Current 80 (uA) |
| Output Isolation Transformer | Toroid with AC output Floating with Respect to Earth Ground |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Output (Watts) | 1800 |
| Output Nominal Voltage | 115V/230V (Selected by Output Switch) Can also be step up or step down Selected when Installing Fuses. |
| Output Receptacles | (8) C13 |
| Output Voltage Regulation (Line Mode) | 3.6% |
| Physical | |
| Cooling Method | Convection |
| Shipping Dimensions (hwd / cm) | 27.99 x 44.50 x 50.01 |
| Shipping Dimensions (hwd / in.) | 11.02 x 17.52 x 19.69 |
| Unit Dimensions (hwd / cm) | 14 x 30 x 35 |
| Unit Dimensions (hwd / in.) | 5.510 x 11.810 x 13.780 |
| Unit Weight (kg) | 23.23 |
| Unit Weight (lbs.) | 51.21 |
| Color | White |
| Material Of Construction | Metal (Cabinet) |
| Shipping Weight (kg) | 23.23 |
| Shipping Weight (lbs.) | 51.21 |
| Warranty | |
| Warranty/Returns | 30 Days |