- Tripp Lite SMART1500RMXLN SmartPro 1440VA 1440W 120V Line-Interactive Sine Wave UPS - 8 Outlets Extended Run Network Card Included LCD USB DB9 2U Rack/Tower
Datasheet
The Tripp Lite SMART1500RMXLN is a 1500VA/1350W Smart Online UPS system providing dependable power protection for servers networking equipment and other sensitive electronics. It offers automatic voltage regulation (AVR) to correct voltage fluctuations without using battery power extending battery life. The LCD interface displays real-time UPS status load level and battery information.
This 2U rackmount UPS features USB and DB9 serial ports for local management and includes the WebcardLX network management card enabling remote monitoring and control via SNMP web browser or telnet/SSH. Its comprehensive features make the SMART1500RMXLN ideal for ensuring business continuity in demanding network environments.
| APPLICATIONS | |
| UPS Applications | Large Network; High-End Desktop/Small Network |
| COMMUNICATIONS | |
| Communications Cable | Micro-USB USB and DB9 cabling included |
| Communications Interface | Contact closure; DB9 Serial; EPO (emergency power off); Micro-USB; Pre-installed network card; USB (HID enabled); USB-A |
| Emergency Power Off (EPO)/Remote On-Off (ROO) | Yes |
| EPO Port | RJ11 interface jack with 4-meter cable included. Supports normally open and normally closed EPO systems |
| Network Management Card Description | Network management card included |
| Network Monitoring Port | RJ45 Network port Micro-USB Configuration/Console port USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. |
| Network Monitoring Port Description | Pre-installed WEBCARDLXE supports detailed monitoring and management of UPS and site power conditions. Not compatible with WEBCARDLX. |
| Network UPS Tools (NUT) Compatibility | NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert Local software at https://tripplite.eaton.com/products/power-alert |
| SNMP Compatibility | SNMP V1 V2c V3 |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMART1500RMXLN |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
| Grounding Details | Rear panel grounding lug |
| High Availability UPS Features | Auto Probe Monitoring and Reboot (included); Automatic Voltage Regulation (AVR); Expandable battery backup; Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 151 |
| Low Voltage Transfer to Battery Power (Setpoint) | 80 (adjustable to 70V) |
| Transfer Time | 1-4ms for normal mode >5ms for sensitive mode |
| OVERVIEW | |
| UPC Code | 037332178022 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); NOM (Mexico); UL 1778 |
| Product Compliance | RoHS; FCC Part 15 Class B (USA) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 380 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and perform the applicable action to resolve the condition. If the alarm status changes the alarm beeps again overriding the previous alarm silencing |
| Audible Alarm | Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions |
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
| LED Indicators | 3 status-indicating LEDs (normal battery mode alarm/fault); LED colors (green = ON orange = On battery flashing orange = below warning level red = alarm/fault). LX Platform Interface Status: Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing) 100 Mbps (On steady). Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec). |
| Switches | 5 pushbutton switches control OFF / ON power status ENTER UP and DOWN selection and ESC control functions. LX Platform Interface: Recessed reset switch for interface reboot and factory reset |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Reduces incoming voltage between 132-151V by 13% (Normal Mode); 138-152V (Extended mode) |
| Undervoltage Correction | Boost incoming voltages between 81-102V by 15% (Normal Mode); 71-92V by 15% (Extended Mode) |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 80 to 151V (Normal Mode) or 70-153V (Extended Mode) |
| Battery | |
| Battery Access | Front panel battery access door |
| Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% (typical full load discharge) |
| Battery Replacement Description | Hot-swappable user replaceable 48V internal battery cartridge |
| DC System Voltage (VDC) | 48 |
| Expandable Runtime | Yes |
| Runtime Full Load (min.) | 5.1 min. (1440w) |
| Runtime Half Load (min.) | 15.1 min. (720w) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 83 |
| AC Mode Efficiency Rating (100% Load) | 96% |
| Audible Noise | 45 dBA maximum front side 1m |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 504 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Elevation (ft.) | 0-32808 |
| Storage Elevation (m) | 0-10000 |
| Storage Temperature Range | 5 to 122F (-15 to +50C) |
| Operating Elevation | 0-10000 ft. (0-3000 m) |
| Input | |
| Input Circuit Breakers | 80V-151V; adjustable to 70-153V |
| Input Phase | Single-Phase |
| Maximum Input Amps | 12 |
| Nominal Input Voltage(s) Supported | 120V AC |
| Rated input current (Maximum Load) | 12A (120V) |
| Recommended Electrical Service | 15A 120V |
| UPS Input Connection Type | 5-15P |
| UPS Input Cord Length (ft.) | 10 |
| UPS Input Cord Length (m) | 3.1 |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | Two switchable two-outlet 5-15R load banks |
| Nominal Output Voltage(s) Supported | 110V; 115V; 120V |
| Nominal Voltage Details | 120v nominal output in battery mode |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 1.44 |
| Output Capacity (kW) | 1.44 |
| Output Capacity (VA) | 1440 |
| Output Capacity (Watts) | 1440 |
| Output Receptacles | (8) 5-15R |
| Output Voltage Regulation (Battery Mode) | -10% +6% |
| Output Voltage Regulation (Line Mode) | 120V (-13% +15%) |
| Power Factor | 1 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount; Tower |
| Minimum Required Rack Depth (cm) | 50.80 |
| Minimum Required Rack Depth (inches) | 20 |
| Minimum Required Rack Depth with External Battery Pack (cm) | 51 |
| Minimum Required Rack Depth with External Battery Pack (in.) | 20 |
| Minimum Required Rack Depth without External Battery Pack (cm) | 51 |
| Minimum Required Rack Depth without External Battery Pack (in.) | 20 |
| Mounting Details | Included 4-post mounting kit enables installation in 4 post racks. Two ABS mounting stands enables the UPS to be configured in an upright tower orientation. |
| Primary Form Factor | Rackmount; Tower |
| Primary UPS Depth (mm) | 447 |
| Primary UPS Height (mm) | 88 |
| Primary UPS Width (mm) | 447 |
| Shipping Dimensions (hwd / cm) | 24.00 x 49.80 x 58.50 |
| Shipping Dimensions (hwd / in.) | 9.45 x 19.60 x 23.03 |
| Unit Dimensions (hwd / in.) | 3.450 x 17.200 x 17.600 |
| Unit Weight (kg) | 23.00 |
| Unit Weight (lbs.) | 50.706 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd cm) | 8.76 x 44.70 x 44.70 |
| UPS Power Module Dimensions (hwd in.) | 3.45 x 17.6 x 17.6 |
| UPS Power Module Weight (kg) | 23.00 |
| UPS Power Module Weight (lbs.) | 50.71 |
| Rack Height | 2U |
| Shipping Weight (kg) | 28.00 |
| Shipping Weight (lbs.) | 61.73 |
| Warranty | |
| Warranty/Returns | 30 Days |