Tripp Lite SUINT3000XLCD SmartOnline 230V 3kVA 2700W On-Line Double-Conversion UPS Tower Extended Run Network Card Options LCD USB DB9
$1,708.42
Manufacturer:Eaton / Tripp Lite
Model:SUINT3000XLCD
Condition:New
Availability:Out Of Stock
Condition:New
Availability:Out Of Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SmartOnline Series
- UPS Battery Backup
- Search
- Tripp Lite SUINT3000XLCD SmartOnline 230V 3kVA 2700W On-Line Double-Conversion UPS Tower Extended Run Network Card Options LCD USB DB9
Datasheet
The Tripp Lite SUINT3000XLCD SmartOnline 230V 3kVA 2.7kW UPS provides continuous regulated AC power to connected equipment even during severe power fluctuations. This true double-conversion UPS isolates sensitive electronics from raw utility power offering the highest level of protection against blackouts brownouts voltage sags surges and line noise.
Featuring an intuitive LCD interface advanced communication options and scalable runtime the SUINT3000XLCD is ideal for protecting mission-critical servers networking equipment and telecommunications systems. Ensure reliable operation and safeguard your valuable data with this robust and dependable UPS solution.
| APPLICATIONS | |
| UPS Applications | Mission Critical Applications |
| COMMUNICATIONS | |
| Communications Cable | USB and DB9 cabling included |
| Communications Interface | DB9 Serial; Slot for SNMP/Web interface; USB (HID enabled) |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SUINT3000XLCD |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | High efficiency economy mode operation |
| High Availability UPS Features | Auto Probe Monitoring (requires WEBCARDLXE); Automatic inverter bypass; Hot swappable batteries; Remote management; Surge/noise protection; Zero transfer time |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 280 |
| Low Voltage Transfer to Battery Power (Setpoint) | 80V (<50% load) 175V (100% load) |
| Transfer Time | Zero transfer time (0 ms.) |
| OVERVIEW | |
| UPC Code | 037332194916 |
| UPS Type | On-Line |
| STANDARDS & COMPLIANCE | |
| Product Compliance | RoHS; CE (Europe) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 425 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
| Audible Alarm | Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions |
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional information |
| Switches | ON switch supports inverter-on battery-test alarm-off and enter functions; OFF switch supports inverter-off and fault-clear functions; SETUP switch enables scroll-down and enter setup-mode functions |
| VOLTAGE REGULATION | |
| Overvoltage Correction | 2% output voltage regulation during overvoltages to 280 |
| Undervoltage Correction | 2% output voltage regulation during undervoltages to 80V (50% load) 175V (100% load) |
| Voltage Regulation Description | Online double-conversion power conditioning |
| Battery | |
| Battery Recharge Rate (Included Batteries) | Less than 6 hours from 10% to 90% (typical full load discharge) |
| DC System Voltage (VDC) | 72 |
| Expandable Runtime | Yes |
| Runtime Full Load (min.) | 4.4 min. (2700W) |
| Runtime Half Load (min.) | 11.2 min. (1350W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Economy Mode BTU / Hr. (Full Load) | 188 |
| AC Economy Mode Efficiency Rating (100% Load) | 98% |
| AC Mode BTU / Hr. (Full Load) | 818 |
| AC Mode Efficiency Rating (100% Load) | 92% |
| Audible Noise | < 52 dB at front side 1m |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 1538 |
| Online Mode Heat Dissipation (BTU/Hr) @ Full Load | 818 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Operating Elevation | 0-3280 ft. (0-1000 m) |
| Input | |
| Input Circuit Breakers | 20A |
| Input Phase | Single-Phase |
| Maximum Input Amps | 15 |
| Nominal Input Voltage Description | 230V factory default |
| Nominal Input Voltage(s) Supported | 220V AC; 230V AC; 240V AC |
| Rated input current (Maximum Load) | 14.6A 220V; 14.0A 230V; 13.4A 240V |
| Recommended Electrical Service | 230V |
| UPS Input Connection Type | C20 inlet |
| UPS Input Cord Length (ft.) | 10 |
| UPS Input Cord Length (m) | 3.1 |
| Output | |
| Crest Factor | 3:1 |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz; BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal. |
| Included Output Power Cables | Includes three C13 to C14 power cables |
| Individually Controllable Load Banks | No |
| Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
| Nominal Voltage Details | 230V default |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 3 |
| Output Capacity (kW) | 2.7 |
| Output Capacity (VA) | 3000 |
| Output Capacity (Watts) | 2700 |
| Output Capacity Details | OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously 125% load for 1 minute; 150% load for 30 seconds; Loads greater than 150% trigger immediate switchover to BYPASS (when input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when input voltage and frequency are OUTSIDE bypass limits) |
| Output Receptacles | (6) C13; (1) C19 |
| Output Voltage Regulation (Battery Mode) | +/- 3% |
| Output Voltage Regulation (Economy Line Mode) | +/- 10% |
| Output Voltage Regulation (Line Mode) | +/- 2% |
| Power Factor | 0.9 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | Tower |
| Primary Form Factor | Tower |
| Primary UPS Depth (mm) | 361 |
| Primary UPS Height (mm) | 325 |
| Primary UPS Width (mm) | 191 |
| Shipping Dimensions (hwd / cm) | 43.69 x 29.97 x 49.02 |
| Shipping Dimensions (hwd / in.) | 17.20 x 11.80 x 19.30 |
| Unit Weight (kg) | 24.86 |
| Unit Weight (lbs.) | 54.8000 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd in.) | 12.8 x 7.5 x 14.2 |
| UPS Power Module Weight (kg) | 24.86 |
| UPS Power Module Weight (lbs.) | 54.8 |
| Shipping Weight (kg) | 30.79 |
| Shipping Weight (lbs.) | 67.87 |
| Warranty | |
| Warranty/Returns | 30 Days |