The Tripp Lite SUINT3000XLCD SmartOnline 230V 3kVA 2.7kW UPS provides continuous regulated AC power to connected equipment even during severe power fluctuations. This true double-conversion UPS isolates sensitive electronics from raw utility power offering the highest level of protection against blackouts brownouts voltage sags surges and line noise.

Featuring an intuitive LCD interface advanced communication options and scalable runtime the SUINT3000XLCD is ideal for protecting mission-critical servers networking equipment and telecommunications systems. Ensure reliable operation and safeguard your valuable data with this robust and dependable UPS solution.

APPLICATIONS
UPS Applications Mission Critical Applications
COMMUNICATIONS
Communications Cable USB and DB9 cabling included
Communications Interface DB9 Serial; Slot for SNMP/Web interface; USB (HID enabled)
Network Management Card Description Network management card optional
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number SUINT3000XLCD
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
Green Energy-Saving Features High efficiency economy mode operation
High Availability UPS Features Auto Probe Monitoring (requires WEBCARDLXE); Automatic inverter bypass; Hot swappable batteries; Remote management; Surge/noise protection; Zero transfer time
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 280
Low Voltage Transfer to Battery Power (Setpoint) 80V (<50% load) 175V (100% load)
Transfer Time Zero transfer time (0 ms.)
OVERVIEW
UPC Code 037332194916
UPS Type On-Line
STANDARDS & COMPLIANCE
Product Compliance RoHS; CE (Europe)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 425
AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
USER INTERFACE ALERTS & CONTROLS
Alarm Cancel Operation Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Audible Alarm Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional information
Switches ON switch supports inverter-on battery-test alarm-off and enter functions; OFF switch supports inverter-off and fault-clear functions; SETUP switch enables scroll-down and enter setup-mode functions
VOLTAGE REGULATION
Overvoltage Correction 2% output voltage regulation during overvoltages to 280
Undervoltage Correction 2% output voltage regulation during undervoltages to 80V (50% load) 175V (100% load)
Voltage Regulation Description Online double-conversion power conditioning
Battery
Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical full load discharge)
DC System Voltage (VDC) 72
Expandable Runtime Yes
Runtime Full Load (min.) 4.4 min. (2700W)
Runtime Half Load (min.) 11.2 min. (1350W)
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Economy Mode BTU / Hr. (Full Load) 188
AC Economy Mode Efficiency Rating (100% Load) 98%
AC Mode BTU / Hr. (Full Load) 818
AC Mode Efficiency Rating (100% Load) 92%
Audible Noise < 52 dB at front side 1m
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load 1538
Online Mode Heat Dissipation (BTU/Hr) @ Full Load 818
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 0-95% non-condensing
Storage Temperature Range 5 to 122F (-15 to 50C)
Operating Elevation 0-3280 ft. (0-1000 m)
Input
Input Circuit Breakers 20A
Input Phase Single-Phase
Maximum Input Amps 15
Nominal Input Voltage Description 230V factory default
Nominal Input Voltage(s) Supported 220V AC; 230V AC; 240V AC
Rated input current (Maximum Load) 14.6A 220V; 14.0A 230V; 13.4A 240V
Recommended Electrical Service 230V
UPS Input Connection Type C20 inlet
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3.1
Output
Crest Factor 3:1
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz; BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.
Included Output Power Cables Includes three C13 to C14 power cables
Individually Controllable Load Banks No
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Nominal Voltage Details 230V default
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Output Capacity (kVA) 3
Output Capacity (kW) 2.7
Output Capacity (VA) 3000
Output Capacity (Watts) 2700
Output Capacity Details OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously 125% load for 1 minute; 150% load for 30 seconds; Loads greater than 150% trigger immediate switchover to BYPASS (when input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when input voltage and frequency are OUTSIDE bypass limits)
Output Receptacles (6) C13; (1) C19
Output Voltage Regulation (Battery Mode) +/- 3%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Line Mode) +/- 2%
Power Factor 0.9
Physical
Cooling Method Fan
Installation Form Factors Supported with Included Accessories Tower
Primary Form Factor Tower
Primary UPS Depth (mm) 361
Primary UPS Height (mm) 325
Primary UPS Width (mm) 191
Shipping Dimensions (hwd / cm) 43.69 x 29.97 x 49.02
Shipping Dimensions (hwd / in.) 17.20 x 11.80 x 19.30
Unit Weight (kg) 24.86
Unit Weight (lbs.) 54.8000
UPS Housing Material Steel
UPS Power Module Dimensions (hwd in.) 12.8 x 7.5 x 14.2
UPS Power Module Weight (kg) 24.86
UPS Power Module Weight (lbs.) 54.8
Shipping Weight (kg) 30.79
Shipping Weight (lbs.) 67.87
Warranty
Warranty/Returns 30 Days