Tripp Lite SUINT1000LCD2UN 208/230V 1000VA 900W Double-Conversion UPS - 6 Outlets Extended Run WEBCARDLXE LCD USB DB9 2U UPS Battery Backup

Tripp Lite SUINT1000LCD2UN 208/230V 1000VA 900W Double-Conversion UPS - 6 Outlets Extended Run WEBCARDLXE LCD USB DB9 2U

$1,402.74
Manufacturer:Eaton / Tripp Lite
Model:SUINT1000LCD2UN
Condition:New
Availability:In Stock
The Tripp Lite SUINT1000LCD2UN a 208/230V 1000VA/900W online UPS offers double-conversion protection for critical equipment. Featuring 6 outlets expandable runtime network management card LCD and USB/DB9 connectivity.
Datasheet

The Tripp Lite SUINT1000LCD2UN is a 2U rack/tower double-conversion online UPS providing reliable 1000VA/900W of power protection for critical servers network equipment and other sensitive electronics. Its pure sine wave output isolates connected equipment from power problems and offers advanced features including an LCD status display USB and DB9 serial ports for monitoring and control.

This 208/230V UPS features 6 outlets extended runtime capabilities with optional external battery packs and includes the WEBCARDLX network management card for remote monitoring and control. The SUINT1000LCD2UN ensures maximum uptime and data protection for your valuable equipment.

APPLICATIONS
UPS Applications Mission Critical Applications
COMMUNICATIONS
Communications Cable USB and DB9 cabling included
Communications Interface Contact closure; DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface; USB (HID enabled)
Network Management Card Description Network management card included
PowerAlert Software Free download from https://tripplite.eaton.com/products/power-alert
WatchDog Compatibility Supports Watchdog application OS and hard-reboot restart options for remote applications
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number SUINT1000LCD2UN
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
Green Energy-Saving Features High efficiency economy mode operation; Individually controllable load banks
Grounding Details Back panel grounding lug included
High Availability UPS Features Auto Probe Monitoring and Reboot (included); Automatic inverter bypass; Hot swappable batteries; Remote management; Surge/noise protection; Zero transfer time
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 288V
Low Voltage Transfer to Battery Power (Setpoint) 160V (100% load) 140V (66% load) 120V (33% load)
Transfer Time 0 ms
OVERVIEW
UPC Code 037332253569
UPS Type On-Line
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); NOM (Mexico); UL 1778
Product Compliance RoHS; SASO (Saudi Arabia); CE (Europe); EAC (Belarus Kazakhstan Russia); ENERGY STAR Qualified
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 627
AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
UPS Dataline Suppression Details Single line dialup / network dataline protection included
USER INTERFACE ALERTS & CONTROLS
Alarm Cancel Operation Power-fail alarm can be silenced by following on-screen prompts
Audible Alarm Audible alarm indicates power failure low battery overload and fault
Front Panel LCD Display Interactive front-panel LCD interface reports UPS operating mode detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options
LED Indicators 4 front panel LEDs: AC input (green) AC output (green) Battery (yellow) Fault (red)
Switches 5 front panel switches: On/Off Up Down and Escape
VOLTAGE REGULATION
Overvoltage Correction 2% output voltage regulation during overvoltages to 288V
Undervoltage Correction 2% output voltage regulation during undervoltages to 160V (100% load) 130V (70% load) 100V (30% load)
Voltage Regulation Description Online double-conversion power conditioning
Battery
Battery Access Front panel battery access door
Battery Recharge Rate (Included Batteries) Less than 4.1 hours from 10% to 90% (typical full load discharge)
Battery Replacement Description Hot-swappable replaceable batteries
DC System Voltage (VDC) 24
Expandable Runtime Yes
Runtime Full Load (min.) 4.7 min. (900W)
Runtime Half Load (min.) 12.3 min. (450W)
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Economy Mode BTU / Hr. (Full Load) 128
AC Economy Mode Efficiency Rating (100% Load) >96%
AC Mode BTU / Hr. (Full Load) 245
AC Mode Efficiency Rating (100% Load) >93%
Audible Noise <45dB at front side 1M
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load 500
Online Mode Heat Dissipation (BTU/Hr) @ Full Load 245
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 5 to 95% non-condensing
Storage Temperature Range 5 to 122F (-15 to 50C)
Input
Input Phase Single-Phase
Maximum Input Amps 5
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
Rated input current (Maximum Load) 4.99A
UPS Input Connection Type C14 inlet
Output
Crest Factor 3:1
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation
Included Output Power Cables Includes 2 C13 to C14 power cables
Individually Controllable Load Banks Yes
Load Management Receptacles Two switchable 2-outlet load banks
Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
Nominal Voltage Details Nominal output voltage is user configured on first power-on
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Output Capacity (kVA) 1
Output Capacity (kW) 0.9
Output Capacity (VA) 1000
Output Capacity (Watts) 900
Output Capacity Details DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 630 watts for 208/220/230/240V output voltages; Max output is 720W (504W in Frequency Conversion mode) at 200V output voltage. OVERLOAD CAPACITY- Supports inverter operation up to 105% load continuously 125% for 3 minutes 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).
Output Receptacles (6) C13
Output Voltage Regulation (Battery Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Line Mode) +/- 2%
Power Factor 0.9
Physical
Cooling Method Fan
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Minimum Required Rack Depth (cm) 48.26
Minimum Required Rack Depth (inches) 19
Minimum Required Rack Depth with External Battery Pack (cm) 48
Minimum Required Rack Depth with External Battery Pack (in.) 18.75
Minimum Required Rack Depth without External Battery Pack (cm) 46
Minimum Required Rack Depth without External Battery Pack (in.) 18
Mounting Details Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Primary Form Factor Rackmount
Primary UPS Depth (mm) 397
Primary UPS Height (mm) 88
Primary UPS Width (mm) 438
Shipping Dimensions (hwd / in.) 9.60 x 19.80 x 23.50
Unit Dimensions (hwd / in.) 3.500 x 17.250 x 15.630
Unit Weight (kg) 12.70
Unit Weight (lbs.) 28.000
UPS Housing Material Metal
UPS Power Module Dimensions (hwd in.) 3.46 x 17.24 x 15.63
UPS Power Module Weight (kg) 12.70
UPS Power Module Weight (lbs.) 28
Rack Height 2U
Shipping Weight (kg) 19.96
Warranty
Warranty/Returns 30 Days