- Power Protection
- Eaton / Tripp Lite
- UPS System
- SmartOnline Series
- UPS Battery Backup
- Search
- Tripp Lite SU3000LCD2UHV 208/240V 3000VA 2.7kW Double-Conversion UPS - 8 Outlets Extended Run Card Slot LCD USB DB9 2U
Datasheet
The Tripp Lite SU3000LCD2UHV SmartOnline UPS offers 3000VA/2700W of double-conversion power protection for critical server network and telecommunications equipment. Its true online design isolates connected equipment from line noise and power problems providing continuous regulated AC output regardless of input power conditions.
This 2U rackmount UPS features USB and DB9 connectivity for monitoring and management along with an LCD display for status information. The SU3000LCD2UHV operates on 208/240V input and provides reliable backup power during outages ensuring business continuity.
| APPLICATIONS | |
| UPS Applications | Mission Critical Applications |
| COMMUNICATIONS | |
| Communications Cable | USB and DB9 cabling included |
| Communications Interface | Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 plus assignable contact closure pin functions for On-battery On bypass Output-on and Low-battery conditions and remote Shutdown Output-off Reboot and Power-toggle operations |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SU3000LCD2UHV |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | High efficiency economy mode operation; Individually controllable load banks |
| Grounding Details | Back panel grounding lug included |
| High Availability UPS Features | Automatic inverter bypass; Hot swappable batteries; Remote management; Surge/noise protection; Zero transfer time; Auto Probe Monitoring (requires WEBCARDLXE) |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 288V |
| Low Voltage Transfer to Battery Power (Setpoint) | 160V (100% load) 140V (66% load) 120V (33% load) |
| Transfer Time | 0 ms |
| OVERVIEW | |
| UPC Code | 037332180742 |
| UPS Type | On-Line |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); NOM (Mexico); UL 1778 |
| Product Compliance | RoHS; CE (Europe); ENERGY STAR Qualified; FCC Part 15 Class A (USA) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 570 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| UPS Dataline Suppression Details | Single line dialup / network dataline protection included |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be silenced by following on-screen prompts |
| Audible Alarm | Audible alarm indicates power failure low battery overload and fault |
| Front Panel LCD Display | Interactive front-panel LCD interface reports UPS operating mode detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options |
| LED Indicators | 4 front panel LEDs: AC input (green) AC output (green) Battery (yellow) Fault (red) |
| Switches | 5 front panel switches: On/Off Up Down and Escape |
| VOLTAGE REGULATION | |
| Overvoltage Correction | 2% output voltage regulation during overvoltages to 288 |
| Undervoltage Correction | 2% output voltage regulation during undervoltages to 160V (100% load) 130V (70% load) 100V (30% load) |
| Voltage Regulation Description | Online double-conversion power conditioning |
| Battery | |
| Battery Access | Front panel battery access door |
| Battery Recharge Rate (Included Batteries) | 3.0 hours from 10% to 90% (typical full load discharge) |
| Battery Replacement Description | Hot-swappable replaceable batteries |
| DC System Voltage (VDC) | 72 |
| Expandable Runtime | Yes |
| Runtime Full Load (min.) | 5 min. (2700W) |
| Runtime Half Load (min.) | 13.5 min. (1350W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Economy Mode BTU / Hr. (Full Load) | 588 |
| AC Economy Mode Efficiency Rating (100% Load) | >95% |
| AC Mode BTU / Hr. (Full Load) | 933 |
| AC Mode Efficiency Rating (100% Load) | >90% |
| Audible Noise | <50dB at front side 1M |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 1399 |
| Online Mode Heat Dissipation (BTU/Hr) @ Full Load | 933 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 5 to 95% non-condensing |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Operating Elevation | 0-10000 ft. (0-3000 m) |
| Input | |
| Input Phase | Single-Phase |
| Maximum Input Amps | 15 |
| Nominal Input Voltage(s) Supported | 200V AC; 208V AC; 220V AC; 230V AC; 240V AC |
| Rated input current (Maximum Load) | 14.97A |
| Recommended Electrical Service | 208/240V 20A |
| UPS Input Connection Type | L6-20P |
| UPS Input Cord Length (ft.) | 10 |
| UPS Input Cord Length (m) | 3.1 |
| Output | |
| Crest Factor | 3:1 |
| Frequency Compatibility | 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion |
| Frequency Compatibility Details | Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | Two switchable outlet load banks (2 NEMA 6-15/20R outlets per bank) |
| Nominal Output Voltage(s) Supported | 200V; 208V; 220V; 230V; 240V |
| Nominal Voltage Details | Nominal output voltage is user configured on first power-on |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 3 |
| Output Capacity (kW) | 2.7 |
| Output Capacity (VA) | 3000 |
| Output Capacity (Watts) | 2700 |
| Output Capacity Details | DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 1890 watts for 208/220/230/240V output voltages; Max output is reduced to 2160W at 200V output voltage in all operating modes. OVERLOAD CAPACITY- Supports inverter operation up to 105% load continuously 125% for 3 minutes 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits). |
| Output Receptacles | (6) 6-15/20R; (2) L6-20R |
| Output Voltage Regulation (Battery Mode) | +/- 2% |
| Output Voltage Regulation (Economy Line Mode) | +/- 10% |
| Output Voltage Regulation (Line Mode) | +/- 2% |
| Power Factor | 0.9 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount |
| Minimum Required Rack Depth (cm) | 71.12 |
| Minimum Required Rack Depth (inches) | 28 |
| Minimum Required Rack Depth with External Battery Pack (cm) | 77 |
| Minimum Required Rack Depth with External Battery Pack (in.) | 30.25 |
| Minimum Required Rack Depth without External Battery Pack (cm) | 74 |
| Minimum Required Rack Depth without External Battery Pack (in.) | 29.25 |
| Mounting Details | 4 post installation accessories included |
| Primary Form Factor | Rackmount |
| Primary UPS Depth (mm) | 616 |
| Primary UPS Height (mm) | 88 |
| Primary UPS Width (mm) | 438 |
| Shipping Dimensions (hwd / cm) | 24.00 x 59.99 x 76.00 |
| Shipping Dimensions (hwd / in.) | 9.45 x 23.62 x 29.92 |
| Unit Dimensions (hwd / in.) | 3.460 x 17.240 x 24.250 |
| Unit Weight (kg) | 32.12 |
| Unit Weight (lbs.) | 70.8100 |
| UPS Housing Material | Metal |
| UPS Power Module Dimensions (hwd cm) | 8.79 x 43.79 x 61.60 |
| UPS Power Module Dimensions (hwd in.) | 3.46 x 17.24 x 24.25 |
| UPS Power Module Weight (kg) | 32.12 |
| UPS Power Module Weight (lbs.) | 70.81 |
| Rack Height | 2U |
| Shipping Weight (kg) | 39.01 |
| Shipping Weight (lbs.) | 86.00 |
| Warranty | |
| Warranty/Returns | 30 Days |