Tripp Lite SMX500RT1U SmartPro 230V 500VA 300W Line-Interactive UPS 1U Rack/Tower Network Card Options USB DB9 Serial
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SMX Series
- UPS Battery Backup
- Search
- Tripp Lite SMX500RT1U SmartPro 230V 500VA 300W Line-Interactive UPS 1U Rack/Tower Network Card Options USB DB9 Serial
The Tripp Lite SMX500RT1U Pro 500VA 230V 1U UPS 6Outlet DB9/USB is a versatile power protection solution designed for international use. This smart rackmount UPS provides 500VA/300W of battery backup power safeguarding connected equipment from power outages and surges. Its compact 1U design conserves valuable rack space while offering six outlets and essential connectivity options.
Equipped with Automatic Voltage Regulation (AVR) the SMX500RT1U corrects minor voltage fluctuations without switching to battery power extending battery life. The included DB9 and USB ports allow for convenient communication and monitoring. This UPS is ideal for protecting servers networking equipment and other sensitive electronics in international rackmount environments.
| APPLICATIONS | |
| UPS Applications | Large Network; High-End Desktop/Small Network |
| COMMUNICATIONS | |
| Communications Cable | USB and DB9 cabling included |
| Communications Interface | USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMX500RT1U |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
| Grounding Details | Back panel grounding lug |
| High Availability UPS Features | Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 264 |
| Low Voltage Transfer to Battery Power (Setpoint) | 187 |
| Transfer Time | 2-4 milliseconds |
| OVERVIEW | |
| UPC Code | 037332119254 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); IEC/EN 62040; UL 1778 |
| Product Compliance | RoHS; CE (Europe); EAC (Belarus Kazakhstan Russia) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 480 |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch |
| Audible Alarm | Audible alarm indicates power-failure overload and low-battery conditions |
| LED Indicators | 5 LEDs indicate line power battery power overload voltage regulation and battery low/replace status |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| VOLTAGE REGULATION | |
| Undervoltage Correction | Input voltages between 187 and 215 are boosted by 14% |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 187 |
| Battery | |
| Battery Access | Battery access door |
| Battery Recharge Rate (Included Batteries) | Less than 12 hours to 90% |
| Battery Replacement Description | Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 12 |
| Expandable Runtime | No |
| Runtime Full Load (min.) | 3 min. (300W) |
| Runtime Half Load (min.) | 14 min. (150W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 35 |
| AC Mode Efficiency Rating (100% Load) | 97% |
| Audible Noise | 45 dBA maximum front side 1m |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Input | |
| Input Circuit Breakers | 7A thermal breaker |
| Input Phase | Single-Phase |
| Maximum Input Amps | 7 |
| Nominal Input Voltage Description | Accepts inputs between 187 and 265V for AC mode operation |
| Nominal Input Voltage(s) Supported | 230V AC |
| Rated input current (Maximum Load) | 7A (Maximum input with 300W UPS and 1310W surge-only loads) |
| UPS Input Connection Description | C14 inlet accepts user-supplied AC power cord with country-specific plug; Includes 2 1.8m C13 to C14 power cables |
| UPS Input Connection Type | C14 inlet |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Automatic frequency selection; 50Hz (46-54Hz) / 60Hz (56-64Hz) |
| Hot-Swap PDU options | PDUBHV10 (2U / 8 C13 outlets) |
| Included Output Power Cables | Two 1.8m IEC320-C13 to C14 load jumper cables |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | One switchable single-outlet C13 load bank |
| Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
| Nominal Voltage Details | 230v nominal inverter output voltage |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Output Amp Capacity | 2.17A maximum (UPS outlets) / 7A maximum (UPS + Surge-only Outlets) |
| Output Capacity (kVA) | 0.5 |
| Output Capacity (kW) | 0.3 |
| Output Capacity (VA) | 500 |
| Output Capacity (Watts) | 300 |
| Output Receptacles | (6) C13 |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Output Voltage Regulation (Line Mode) | -8% +15% |
| Power Factor | 0.6 |
| UPS Output Receptacles (Surge Suppression Only) | 5 UPS outlets 1 surge-only outlet |
| Physical | |
| Installation Form Factors Supported with Included Accessories | 2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount; Tower |
| Minimum Required Rack Depth (cm) | 38.10 |
| Minimum Required Rack Depth (inches) | 15 |
| Mounting Details | Included mounting brackets provide front-rail installation in 2 or 4 post racks plus upright tower configurations |
| Primary Form Factor | Rackmount; Tower |
| Primary UPS Depth (mm) | 286 |
| Primary UPS Height (mm) | 44 |
| Primary UPS Width (mm) | 440 |
| Shipping Dimensions (hwd / cm) | 10.67 x 40.13 x 53.34 |
| Shipping Dimensions (hwd / in.) | 4.20 x 15.80 x 21.00 |
| Unit Dimensions (hwd / in.) | 1.730 x 17.320 x 11.260 |
| Unit Weight (kg) | 7.40 |
| Unit Weight (lbs.) | 16.310 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd cm) | 4.39 x 43.99 x 28.60 |
| UPS Power Module Dimensions (hwd in.) | 1.73 x 17.32 x 11.26 |
| UPS Power Module Weight (kg) | 8.03 |
| UPS Power Module Weight (lbs.) | 17.7 |
| Rack Height | 1U |
| Shipping Weight (kg) | 8.03 |
| Shipping Weight (lbs.) | 17.70 |
| Warranty | |
| Warranty/Returns | 30 Days |