Tripp Lite SMX2200XLRT2UN SmartPro 230V 2200VA 1920W Line-Interactive Sine Wave UPS 2U Extended Run WEBCARDLX LCD USB DB9 UPS Battery Backup

Tripp Lite SMX2200XLRT2UN SmartPro 230V 2200VA 1920W Line-Interactive Sine Wave UPS 2U Extended Run WEBCARDLX LCD USB DB9

$1,721.36
Manufacturer:Eaton / Tripp Lite
Model:SMX2200XLRT2UN
Condition:New
Availability:In Stock
The Tripp Lite SMX2200XLRT2UN SmartPro UPS safeguards critical 230V equipment with 2200VA/1920W sine wave power extended runtime and advanced management features. Ideal for 2U rack/tower applications.
Datasheet

The Tripp Lite SMX2200XLRT2UN SmartPro UPS provides reliable battery backup and surge protection for connected devices. Delivering 2200VA/1920W of pure sine wave output at 230V this 2U rack/tower mountable UPS offers extended runtime capabilities to keep critical systems operational during power outages. The intuitive LCD interface provides detailed status information.

Equipped with USB and DB9 communication ports as well as compatibility with Tripp Lite's WEBCARDLX (sold separately) the SMX2200XLRT2UN allows for advanced monitoring and management. This makes it ideal for servers networking equipment and other sensitive electronics in demanding applications.

APPLICATIONS
UPS Applications Large Network; High-End Desktop/Small Network
COMMUNICATIONS
Communications Cable USB DB9 and EPO cabling included
Communications Interface DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface; USB (HID enabled)
Network Management Card Description Network management card included
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert
WatchDog Compatibility Supports Watchdog application OS and hard-reboot restart options for remote applications
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number SMX2200XLRT2UN
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
Grounding Details Back panel grounding lug
High Availability UPS Features Auto Probe Monitoring and Reboot (included); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 278V
Low Voltage Transfer to Battery Power (Setpoint) 158V
Transfer Time 6 ms. (AC to DC) / 1 ms. (DC to AC)
OVERVIEW
UPC Code 037332256430
UPS Type Line-Interactive
STANDARDS & COMPLIANCE
Product Certifications GOST (Russia)
Product Compliance RoHS; CE (Europe)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 350
AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
USER INTERFACE ALERTS & CONTROLS
Alarm Cancel Operation Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Audible Alarm Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
Switches 3 pushbutton switches control OFF / ON power status MODE selection and MUTE / ENTER control functions
VOLTAGE REGULATION
Overvoltage Correction Voltage reduction of 12% applies when input is between 244-278V
Severe Undervoltage Correction Voltage boost of 24% applies when input voltage is between 158-182V
Undervoltage Correction Voltage boost of 12% applies when input voltage is between 183-206V
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 158 to 278
Battery
Battery Access Front panel battery access door
Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90% (typical full load discharge)
Battery Replacement Description Hot-swappable user replaceable batteries
DC System Voltage (VDC) 48
Expandable Runtime Yes
Runtime Full Load (min.) 5 min. (1920W)
Runtime Half Load (min.) 11.9 min. (960W)
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Mode BTU / Hr. (Full Load) 161
AC Mode Efficiency Rating (100% Load) 98%
Audible Noise 45 dBA maximum front side 1m
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 0-95% non-condensing
Storage Temperature Range 5 to 122F (-15 to 50C)
Input
Input Circuit Breakers 15A
Input Phase Single-Phase
Maximum Input Amps 11
Nominal Input Voltage(s) Supported 230V AC
Rated input current (Maximum Load) 10.7A
UPS Input Connection Description IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
UPS Input Connection Type C20 inlet
Output
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Hot-Swap PDU options PDUBHV20 (2U / 6 C13 2 C19 outlets)
Included Output Power Cables Includes 3 C13 to C14 output power cables
Individually Controllable Load Banks Yes
Load Management Receptacles Two switchable single-outlet C13 load banks
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Nominal Voltage Details 230V nominal output in battery mode
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Output Capacity (kVA) 2.2
Output Capacity (kW) 1.92
Output Capacity (VA) 2200
Output Capacity (Watts) 1920
Output Receptacles (8) C13
Output Voltage Regulation (Battery Mode) +/- 5%
Output Voltage Regulation (Line Mode) -15% +6%
Power Factor 0.87
Physical
Cooling Method Fan
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Minimum Required Rack Depth (cm) 58.42
Minimum Required Rack Depth (inches) 23
Minimum Required Rack Depth with External Battery Pack (cm) 67
Minimum Required Rack Depth with External Battery Pack (in.) 26.5
Minimum Required Rack Depth without External Battery Pack (cm) 55
Minimum Required Rack Depth without External Battery Pack (in.) 21.75
Mounting Details Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Primary Form Factor Rackmount
Primary UPS Depth (mm) 495
Primary UPS Height (mm) 89
Primary UPS Width (mm) 445
Shipping Dimensions (hwd / in.) 8.70 x 24.20 x 21.50
Unit Weight (kg) 31.18
Unit Weight (lbs.) 68.750
UPS Housing Material Steel
UPS Power Module Dimensions (hwd in.) 3.50 x 17.50 x 19.50
UPS Power Module Weight (kg) 31.18
UPS Power Module Weight (lbs.) 68.75
Rack Height 2U
Shipping Weight (kg) 36.76
Warranty