Tripp Lite SMX1500XLRT2UN SmartPro 1500VA 1500W 208V Line-Interactive Sine Wave UPS - 8 Outlets Extended Run Network Card Included LCD USB DB9 2U Rack/Tower UPS Battery Backup

Tripp Lite SMX1500XLRT2UN SmartPro 1500VA 1500W 208V Line-Interactive Sine Wave UPS - 8 Outlets Extended Run Network Card Included LCD USB DB9 2U Rack/Tower

$1,403.17
Manufacturer:Eaton / Tripp Lite
Model:SMX1500XLRT2UN
Condition:New
Availability:In Stock
The Tripp Lite SMX1500XLRT2UN UPS safeguards critical 230V equipment with 1500VA/1350W of line-interactive sine wave power extended runtime capability and USB/DB9 connectivity. Ideal for rackmount applications with its 2U form factor.
Datasheet

The Tripp Lite SMX1500XLRT2UN SmartPro 1500VA 1350W Line-Interactive Sine Wave UPS offers premium power protection for connected equipment. Featuring a 2U rackmount design it delivers 1500VA/1350W of reliable battery backup and surge suppression with pure sine wave output for sensitive electronics. The included WEBCARDLX network interface card enables remote monitoring and control.

This UPS boasts an LCD status display for at-a-glance monitoring USB and DB9 serial ports for communication and control plus extended runtime capabilities for longer outages. The SMX1500XLRT2UN is a robust power solution for protecting critical servers networking equipment and other sensitive devices in 230V environments.

APPLICATIONS
UPS Applications Large Network; High-End Desktop/Small Network
COMMUNICATIONS
Communications Cable Micro-USB USB and DB9 cabling included
Communications Interface Contact closure; DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface; USB
Emergency Power Off (EPO)/Remote On-Off (ROO) Yes
Network Compatibility 10 Mbps; 100 Mbps (Fast Ethernet)
Network Management Card Description Network management card included
Network Monitoring Port RJ45 Network port Micro-USB Configuration/Console port USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.
Network Monitoring Port Description Pre-installed WEBCARDLXE supports detailed monitoring and management of UPS and site power conditions. Not compatible with WEBCARDLX.
Network UPS Tools (NUT) Compatibility NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
PowerAlert Software For local monitoring via the UPSs built-in communication ports download PowerAlert Office software at https://tripplite.eaton.com/poweralert
SNMP Compatibility SNMP V1 V2c V3
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number SMX1500XLRT2UN
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
Grounding Details Rear panel grounding lug
High Availability UPS Features Auto Probe Monitoring and Reboot (included); Automatic Voltage Regulation (AVR); Expandable battery backup; Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 294 (Normal/Extended Modes)
Low Voltage Transfer to Battery Power (Setpoint) 160V (Normal Mode) 150V (Extended Mode)
Transfer Time 1-4ms for normal mode >5ms for sensitive mode
OVERVIEW
UPC Code 037332256423
UPS Type Line-Interactive
STANDARDS & COMPLIANCE
Product Certifications CAN/CSA C22.2; EN 62040-2; EN 62040-3; IEC 62040-2; UL 1778; cTUVus
Product Compliance CE (Europe); ENERGY STAR Qualified; FCC Part 15 Class A (USA); RoHS; UKCA
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 175
AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
USER INTERFACE ALERTS & CONTROLS
Alarm Cancel Operation Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and perform the applicable action to resolve the condition. If the alarm status changes the alarm beeps again overriding the previous alarm silencing
Audible Alarm Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
LED Indicators UPS: 3 status-indicating LEDs (normal battery mode alarm/fault); LED colors (green = ON orange = On battery flashing orange = below warning level red = alarm/fault). LX Platform Interface Status: Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing) 100 Mbps (On steady). Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec).
Switches 5 pushbutton switches control OFF / ON power status ENTER UP and DOWN selection and ESC control functions. LX Platform Interface: Recessed reset switch for interface reboot and factory reset
VOLTAGE REGULATION
Overvoltage Correction Reduces incoming voltage between 265-294V (Normal Mode / Extended Mode) by 13%
Undervoltage Correction Increases incoming voltage between 162-184V (Normal Mode) or 151-184V (Extended Mode) by 15%
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 150 to 294V
Battery
Battery Access Front panel battery access door
Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90% (typical full load discharge)
Battery Replacement Description Hot-swappable user replaceable batteries
DC System Voltage (VDC) 48
Expandable Runtime Yes
Runtime Full Load (min.) 5 min. (1500W)
Runtime Half Load (min.) 14 min. (750W)
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Mode BTU / Hr. (Full Load) 106
AC Mode Efficiency Rating (100% Load) 98%
Audible Noise 45 dBA maximum front side 1m
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load 699
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 20 to 95% non-condensing
Storage Elevation (ft.) 0-32808
Storage Elevation (m) 0-10000
Storage Temperature Range 5 to 122F (-15 to 50C)
Operating Elevation 0-10000 ft. (0-3000 m)
Input
Input Phase Single-Phase
Maximum Input Amps 10
Nominal Input Voltage(s) Supported 208V AC
Rated input current (Maximum Load) 10A
UPS Input Connection Description IEC320-C14 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
UPS Input Connection Type C14 inlet
Output
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Hot-Swap PDU options PDUBHV10 (2U / 8 C13 outlets)
Included Output Power Cables Set of 2 C13 to C14 power cables included
Individually Controllable Load Banks Yes
Load Management Receptacles Two switchable two-outlet C13 load banks
Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
Nominal Voltage Details 208V nominal output in battery mode
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Output Capacity (kVA) 1.5
Output Capacity (kW) 1.5
Output Capacity (VA) 1500
Output Capacity (Watts) 1500
Output Receptacles (8) C13
Output Voltage Regulation (Battery Mode) -10% +6%
Output Voltage Regulation (Line Mode) 208V (-13% +15%)
Power Factor 1.0
Physical
Cooling Method Fan
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount; Tower
Minimum Required Rack Depth (cm) 53.34
Minimum Required Rack Depth (inches) 21
Minimum Required Rack Depth with External Battery Pack (cm) 53
Minimum Required Rack Depth with External Battery Pack (in.) 21
Minimum Required Rack Depth without External Battery Pack (cm) 53
Minimum Required Rack Depth without External Battery Pack (in.) 21
Mounting Details Included mounting bracket enables installation in 4 post racks. Two ABS mounting stands enables the UPS to be configured in an upright tower orientation.
Primary Form Factor Rackmount; Tower
Primary UPS Depth (mm) 447
Primary UPS Height (mm) 86
Primary UPS Width (mm) 437
Shipping Dimensions (hwd / in.) 9.40 x 19.60 x 23.00
Unit Dimensions (hwd / in.) 3.400 x 17.200 x 17.600
Unit Weight (kg) 22.41
Unit Weight (lbs.) 49.4
UPS Housing Material Steel
UPS Power Module Dimensions (hwd in.) 3.4 x 17.2 x 17.6
UPS Power Module Weight (kg) 20.18
UPS Power Module Weight (lbs.) 44.5
Rack Height 2U
Shipping Weight (kg) 27.90
Warranty
Warranty/Returns 30 Days