Datasheet
The Tripp Lite SMC10002URM 1000VA/700W UPS offers premium protection for critical rack-mounted equipment. It provides pure sine wave output automatic voltage regulation (AVR) and USB communication ports for seamless integration with network management systems. Its compact 2U design optimizes valuable rack space.
Delivering reliable battery backup power during outages the SMC10002URM safeguards sensitive electronics from damaging surges and spikes. The informative LCD display provides real-time status updates while the included USB cable and power management software enable convenient monitoring and control.
| APPLICATIONS | |
| UPS Applications | Audio/Video; Large Network; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality |
| COMMUNICATIONS | |
| Communications Cable | USB cabling included |
| Communications Interface | DB9 Serial; EPO (emergency power off); USB (HID enabled) |
| Network Management Card Description | Network management not supported |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| Network UPS Tools (NUT) Compatibility | NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMC10002URM |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Grounding Details | Back panel grounding lug |
| High Availability UPS Features | Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 147 |
| Low Voltage Transfer to Battery Power (Setpoint) | 83 |
| Transfer Time | 4 milliseconds (AC to battery) 1 milliseconds (Battery to AC) |
| OVERVIEW | |
| UPC Code | 037332186232 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); UL 1778 |
| Product Compliance | RoHS; FCC Part 15 Class B (USA) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 570 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
| Audible Alarm | Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions |
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
| Switches | 3 pushbutton switches control OFF / ON power status MODE selection and MUTE / ENTER control functions |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Input voltages between 128 and 147 are reduced by 12% |
| Undervoltage Correction | Input voltages between 83 and 107 are boosted by 14% |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147 |
| Battery | |
| Battery Access | Front panel battery access door |
| Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% (typical full load discharge) |
| Battery Replacement Description | Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 24 |
| Expandable Runtime | No |
| Runtime Full Load (min.) | 6.4 min. (700W) |
| Runtime Half Load (min.) | 15.6 min. (350W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 122 |
| AC Mode Efficiency Rating (100% Load) | 95% |
| Audible Noise | 45 dBA maximum front side 1m |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 455 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Operating Elevation | 0-10000 ft. (0-3000 m) |
| Input | |
| Input Circuit Breakers | 10A |
| Input Phase | Single-Phase |
| Maximum Input Amps | 9 |
| Nominal Input Voltage(s) Supported | 120V AC |
| Rated input current (Maximum Load) | 9.2A |
| Recommended Electrical Service | 15A 120V |
| UPS Input Connection Type | 5-15P |
| UPS Input Cord Length (ft.) | 10 |
| UPS Input Cord Length (m) | 3.1 |
| Output | |
| Frequency Compatibility | 60 Hz |
| Individually Controllable Load Banks | No |
| Nominal Output Voltage(s) Supported | 110V; 115V; 120V |
| Nominal Voltage Details | 120v nominal output in battery mode |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 1 |
| Output Capacity (kW) | 0.7 |
| Output Capacity (VA) | 1000 |
| Output Capacity (Watts) | 700 |
| Output Receptacles | (6) 5-15R |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Output Voltage Regulation (Line Mode) | -21% +8% |
| Power Factor | 0.7 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | 2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount |
| Minimum Required Rack Depth (cm) | 40.64 |
| Minimum Required Rack Depth (inches) | 16 |
| Mounting Details | Includes UPSHDEARKIT for 2 point front-mount and 2 point center-mount rackmount installation in 2 and 4 post racks plus wallmount installation; For additional stability in 4 post racks consider optional 4 post mounting accessories 4POSTRAILKIT and 4POSTRAILKITWM |
| Primary Form Factor | Rackmount |
| Primary UPS Depth (mm) | 318 |
| Primary UPS Height (mm) | 88 |
| Primary UPS Width (mm) | 441 |
| Shipping Dimensions (hwd / cm) | 22.10 x 46.99 x 57.66 |
| Shipping Dimensions (hwd / in.) | 8.70 x 18.50 x 22.70 |
| Unit Weight (kg) | 16.06 |
| Unit Weight (lbs.) | 35.4000 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd cm) | 8.76 x 44.07 x 31.75 |
| UPS Power Module Dimensions (hwd in.) | 3.45 x 17.35 x 12.5 |
| UPS Power Module Weight (kg) | 16.06 |
| UPS Power Module Weight (lbs.) | 35.4 |
| Rack Height | 2U |
| Shipping Weight (kg) | 18.14 |
| Shipping Weight (lbs.) | 40.00 |
| Warranty | |
| Warranty/Returns | 30 Days |