Tripp Lite SMART3000RM2U SmartPro 3000VA 3000W 120V Line-Interactive Sine Wave UPS - 7 Outlets Network Card Option LCD USB DB9 2U Rack/Tower
$1,410.04
Manufacturer:Eaton / Tripp Lite
Model:SMART3000RM2U
Condition:New
Availability:In Stock
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SMART Series
- UPS Battery Backup
- Search
- Tripp Lite SMART3000RM2U SmartPro 3000VA 3000W 120V Line-Interactive Sine Wave UPS - 7 Outlets Network Card Option LCD USB DB9 2U Rack/Tower
Datasheet
The Tripp Lite SMART3000RM2U is a 3000VA/2250W 2U rackmount UPS system designed to protect critical server network and telecommunications equipment from blackouts brownouts voltage fluctuations and surges. Its pure sine wave output makes it ideal for sensitive electronics.
This smart UPS features automatic voltage regulation (AVR) USB DB9 serial and SNMP communication ports for remote monitoring and management. It offers advanced features like load segment control and provides reliable battery backup power during outages.
| APPLICATIONS | |
| UPS Applications | High-End Desktop/Small Network; Large Network |
| COMMUNICATIONS | |
| Communications Cable | USB and DB9 cabling included |
| Communications Interface | Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | Network Card Optional. Not compatible with WEBCARDLX. |
| Network UPS Tools (NUT) Compatibility | NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert Office software at https://tripplite.eaton.com/poweralert |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMART3000RM2U |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
| Grounding Details | Rear panel grounding lug |
| High Availability UPS Features | Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 151 |
| Low Voltage Transfer to Battery Power (Setpoint) | 80 |
| Transfer Time | 1-4ms for normal mode |
| OVERVIEW | |
| UPC Code | 037332096685 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CAN/CSA-C22.2 No. 107.3 (Canada); ICES (Canada); NOM (Mexico); UL 1778 |
| Product Compliance | ENERGY STAR Qualified; FCC Part 15 Class A (USA); RoHS |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 380 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and perform the applicable action to resolve the condition. If the alarm status changes the alarm beeps again overriding the previous alarm silencing |
| Audible Alarm | Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions |
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
| LED Indicators | UPS Mode On (Solid Green); Battery Mode (Solid Orange)/ Battery Below Warning Level (Flashing Orange); Fault/Alarm (Solid Red). |
| Switches | 5 pushbutton switches control OFF / ON power status ENTER UP and DOWN selection and ESC control functions |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Reduces incoming voltage between 132-151V by 13% (Normal Mode); 138-152V (Extended mode) |
| Undervoltage Correction | Boost incoming voltages between 81-102V by 15% (Normal Mode); 71-92V by 15% (Extended Mode) |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 150V (Normal mode) adjustable to 70-153V (Extended mode) |
| Battery | |
| Battery Access | Front panel battery access door |
| Battery Recharge Rate (Included Batteries) | Less than 5 hours from 10 to 90% (typical full load discharge) |
| Battery Replacement Description | Hot-swappable user replaceable batteries |
| DC System Voltage (VDC) | 72 |
| Expandable Runtime | No |
| Runtime Full Load (min.) | 3 min. (3000W) |
| Runtime Half Load (min.) | 9 min. (1500W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 173 |
| AC Mode Efficiency Rating (100% Load) | 0.98 |
| Audible Noise | 50 dBA maximum front side 1m |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 944 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 20 to 90% non-condensing |
| Storage Elevation (ft.) | 0-32808 |
| Storage Elevation (m) | 0-10000 |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Operating Elevation | 0-10000 ft. (0-3000 m) |
| Input | |
| Input Phase | Single-Phase |
| Maximum Input Amps | 24 |
| Nominal Input Voltage Description | 80V-151V; adjustable to 70-153V |
| Nominal Input Voltage(s) Supported | 120V AC |
| Rated input current (Maximum Load) | 24A (120V) |
| Recommended Electrical Service | 30A 120V |
| UPS Input Connection Type | L5-30P |
| UPS Input Cord Length (ft.) | 10 |
| UPS Input Cord Length (m) | 3.1 |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | Two switchable two-outlet load banks |
| Nominal Output Voltage(s) Supported | 100V; 110V; 120V; 125V |
| Nominal Voltage Details | 120v nominal output in battery mode |
| Output (Watts) | 3000 |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 3 |
| Output Capacity (kW) | 3 |
| Output Capacity (VA) | 3000 |
| Output Capacity (Watts) | 3000 |
| Output Circuit Breakers | Three 20A output breakers protect 2x 5-20R outlets each |
| Output Receptacles | (6) 5-20R; (1) L5-30R |
| Output Voltage Regulation (Battery Mode) | -10% +6% |
| Output Voltage Regulation (Line Mode) | 120V (-13% +15%) |
| Power Factor | 1 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount; Tower |
| Minimum Required Rack Depth (cm) | 68.58 |
| Minimum Required Rack Depth (inches) | 27 |
| Mounting Details | Rack-mounting hardware Tower support stands |
| Primary Form Factor | Rackmount; Tower |
| Primary UPS Depth (mm) | 602 |
| Primary UPS Height (mm) | 86 |
| Primary UPS Width (mm) | 437 |
| Shipping Dimensions (hwd / cm) | 24.00 x 58.00 x 78.40 |
| Shipping Dimensions (hwd / in.) | 9.44 x 22.83 x 30.86 |
| Unit Dimensions (hwd / in.) | 3.400 x 17.200 x 23.700 |
| Unit Weight (kg) | 33.79 |
| Unit Weight (lbs.) | 74.5 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd cm) | 8.64 x 43.69 x 60.20 |
| UPS Power Module Dimensions (hwd in.) | 3.4 x 17.2 x 23.7 |
| UPS Power Module Weight (kg) | 33.79 |
| UPS Power Module Weight (lbs.) | 74.5 |
| Rack Height | 2U |
| Shipping Weight (kg) | 39.80 |
| Shipping Weight (lbs.) | 87.74 |
| Warranty | |
| Warranty/Returns | 30 Days |