Tripp Lite SMART3000RM2U SmartPro 3000VA 3000W 120V Line-Interactive Sine Wave UPS - 7 Outlets Network Card Option LCD USB DB9 2U Rack/Tower UPS Battery Backup

Tripp Lite SMART3000RM2U SmartPro 3000VA 3000W 120V Line-Interactive Sine Wave UPS - 7 Outlets Network Card Option LCD USB DB9 2U Rack/Tower

$1,410.04
Manufacturer:Eaton / Tripp Lite
Model:SMART3000RM2U
Condition:New
Availability:In Stock
The Tripp Lite SMART3000RM2U is a 3000VA/2250W rackmount UPS with AVR and sine wave output. Provides battery backup surge protection and USB/DB9/SNMP connectivity for critical equipment.
Datasheet

The Tripp Lite SMART3000RM2U is a 3000VA/2250W 2U rackmount UPS system designed to protect critical server network and telecommunications equipment from blackouts brownouts voltage fluctuations and surges. Its pure sine wave output makes it ideal for sensitive electronics.

This smart UPS features automatic voltage regulation (AVR) USB DB9 serial and SNMP communication ports for remote monitoring and management. It offers advanced features like load segment control and provides reliable battery backup power during outages.

APPLICATIONS
UPS Applications High-End Desktop/Small Network; Large Network
COMMUNICATIONS
Communications Cable USB and DB9 cabling included
Communications Interface Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
Network Management Card Description Network management card optional
Network Monitoring Port Description Network Card Optional. Not compatible with WEBCARDLX.
Network UPS Tools (NUT) Compatibility NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
PowerAlert Software For local monitoring via the UPSs built-in communication ports download PowerAlert Office software at https://tripplite.eaton.com/poweralert
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number SMART3000RM2U
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
Grounding Details Rear panel grounding lug
High Availability UPS Features Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 151
Low Voltage Transfer to Battery Power (Setpoint) 80
Transfer Time 1-4ms for normal mode
OVERVIEW
UPC Code 037332096685
UPS Type Line-Interactive
STANDARDS & COMPLIANCE
Product Certifications CAN/CSA-C22.2 No. 107.3 (Canada); ICES (Canada); NOM (Mexico); UL 1778
Product Compliance ENERGY STAR Qualified; FCC Part 15 Class A (USA); RoHS
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 380
AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
USER INTERFACE ALERTS & CONTROLS
Alarm Cancel Operation Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and perform the applicable action to resolve the condition. If the alarm status changes the alarm beeps again overriding the previous alarm silencing
Audible Alarm Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
LED Indicators UPS Mode On (Solid Green); Battery Mode (Solid Orange)/ Battery Below Warning Level (Flashing Orange); Fault/Alarm (Solid Red).
Switches 5 pushbutton switches control OFF / ON power status ENTER UP and DOWN selection and ESC control functions
VOLTAGE REGULATION
Overvoltage Correction Reduces incoming voltage between 132-151V by 13% (Normal Mode); 138-152V (Extended mode)
Undervoltage Correction Boost incoming voltages between 81-102V by 15% (Normal Mode); 71-92V by 15% (Extended Mode)
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 150V (Normal mode) adjustable to 70-153V (Extended mode)
Battery
Battery Access Front panel battery access door
Battery Recharge Rate (Included Batteries) Less than 5 hours from 10 to 90% (typical full load discharge)
Battery Replacement Description Hot-swappable user replaceable batteries
DC System Voltage (VDC) 72
Expandable Runtime No
Runtime Full Load (min.) 3 min. (3000W)
Runtime Half Load (min.) 9 min. (1500W)
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Mode BTU / Hr. (Full Load) 173
AC Mode Efficiency Rating (100% Load) 0.98
Audible Noise 50 dBA maximum front side 1m
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load 944
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 20 to 90% non-condensing
Storage Elevation (ft.) 0-32808
Storage Elevation (m) 0-10000
Storage Temperature Range 5 to 122F (-15 to 50C)
Operating Elevation 0-10000 ft. (0-3000 m)
Input
Input Phase Single-Phase
Maximum Input Amps 24
Nominal Input Voltage Description 80V-151V; adjustable to 70-153V
Nominal Input Voltage(s) Supported 120V AC
Rated input current (Maximum Load) 24A (120V)
Recommended Electrical Service 30A 120V
UPS Input Connection Type L5-30P
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3.1
Output
Frequency Compatibility 50 / 60 Hz
Individually Controllable Load Banks Yes
Load Management Receptacles Two switchable two-outlet load banks
Nominal Output Voltage(s) Supported 100V; 110V; 120V; 125V
Nominal Voltage Details 120v nominal output in battery mode
Output (Watts) 3000
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Output Capacity (kVA) 3
Output Capacity (kW) 3
Output Capacity (VA) 3000
Output Capacity (Watts) 3000
Output Circuit Breakers Three 20A output breakers protect 2x 5-20R outlets each
Output Receptacles (6) 5-20R; (1) L5-30R
Output Voltage Regulation (Battery Mode) -10% +6%
Output Voltage Regulation (Line Mode) 120V (-13% +15%)
Power Factor 1
Physical
Cooling Method Fan
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount; Tower
Minimum Required Rack Depth (cm) 68.58
Minimum Required Rack Depth (inches) 27
Mounting Details Rack-mounting hardware Tower support stands
Primary Form Factor Rackmount; Tower
Primary UPS Depth (mm) 602
Primary UPS Height (mm) 86
Primary UPS Width (mm) 437
Shipping Dimensions (hwd / cm) 24.00 x 58.00 x 78.40
Shipping Dimensions (hwd / in.) 9.44 x 22.83 x 30.86
Unit Dimensions (hwd / in.) 3.400 x 17.200 x 23.700
Unit Weight (kg) 33.79
Unit Weight (lbs.) 74.5
UPS Housing Material Steel
UPS Power Module Dimensions (hwd cm) 8.64 x 43.69 x 60.20
UPS Power Module Dimensions (hwd in.) 3.4 x 17.2 x 23.7
UPS Power Module Weight (kg) 33.79
UPS Power Module Weight (lbs.) 74.5
Rack Height 2U
Shipping Weight (kg) 39.80
Shipping Weight (lbs.) 87.74
Warranty
Warranty/Returns 30 Days