Tripp Lite SMART2200RMXL2U SmartPro 1950VA 1950W 120V Line-Interactive Sine Wave UPS - 7 Outlets Extended Run Network Card Option LCD USB DB9 ENERGY STAR V2.0 2U Rack/Tower UPS Battery Backup

Tripp Lite SMART2200RMXL2U SmartPro 1950VA 1950W 120V Line-Interactive Sine Wave UPS - 7 Outlets Extended Run Network Card Option LCD USB DB9 ENERGY STAR V2.0 2U Rack/Tower

$1,311.47
Manufacturer:Eaton / Tripp Lite
Model:SMART2200RMXL2U
Condition:New
Availability:In Stock
The Tripp Lite SMART2200RMXL2U 2200VA/1600W UPS offers reliable battery backup and surge protection for critical rackmount equipment with AVR LCD display USB and DB9 connectivity in a 2U form factor.
Datasheet

The Tripp Lite SMART2200RMXL2U 2200VA/1600W UPS is a smart rackmount solution designed to safeguard critical equipment from power outages and surges. Featuring automatic voltage regulation (AVR) it corrects minor voltage fluctuations without switching to battery extending battery life. The informative LCD display provides real-time power status and UPS settings.

This 2U rackmount UPS offers USB and DB9 connectivity for seamless integration with your systems enabling automatic shutdown and data saving during extended outages. The SMART2200RMXL2U ensures reliable power protection for servers networking equipment and other sensitive electronics in demanding rack environments.

APPLICATIONS
UPS Applications Large Network
COMMUNICATIONS
Communications Cable USB and DB9 cabling included
Communications Interface Contact closure; DB9 Serial; Slot for SNMP/Web interface; USB (HID enabled)
Network Management Card Description One slot for optional WEBCARDLXE web card. Note: Not compatible with WEBCARDLX
Network Monitoring Port Description Network Card Optional. Not compatible with WEBCARDLX.
Network UPS Tools (NUT) Compatibility NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
PowerAlert Software For local monitoring via the UPSs built-in communication ports download PowerAlert Local software at https://tripplite.eaton.com/poweralert
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number SMART2200RMXL2U
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
Grounding Details Rear panel grounding lug
High Availability UPS Features Automatic Voltage Regulation (AVR); Expandable battery backup; Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 151
Low Voltage Transfer to Battery Power (Setpoint) 80
Transfer Time 1-4ms for normal mode
OVERVIEW
UPC Code 037332118059
UPS Type Line-Interactive
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); UL 1778; NOM (Mexico)
Product Compliance CE (Europe); ENERGY STAR Qualified; FCC Part 15 Class B (USA)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 380
AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
USER INTERFACE ALERTS & CONTROLS
Alarm Cancel Operation Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and perform the applicable action to resolve the condition. If the alarm status changes the alarm beeps again overriding the previous alarm silencing
Audible Alarm Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions
Front Panel LCD Display Front panel rotatable LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
Switches 5 pushbutton switches control OFF / ON power status ENTER UP and DOWN selection and ESC control functions
VOLTAGE REGULATION
Overvoltage Correction Reduces incoming voltage between 132-151V by 13%
Undervoltage Correction Boost incoming voltages between 88-102V by 15%
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
Battery
Battery Access Front panel battery access door
Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90% (typical full load discharge)
Battery Replacement Description Hot-swappable user replaceable batteries
DC System Voltage (VDC) 72
Expandable Runtime Yes
Runtime Full Load (min.) 4 min. (1950W)
Runtime Half Load (min.) 12 min. (975W)
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Mode BTU / Hr. (Full Load) 109
AC Mode Efficiency Rating (100% Load) 96%
Audible Noise 45 dBA maximum front side 1m
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load 591
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 20 to 95% non-condensing
Storage Elevation (ft.) 0-32808
Storage Elevation (m) 0-10000
Storage Temperature Range 5 to 122F (-15 to 50C)
Operating Elevation 0-10000 ft. (0-3000 m)
Input
Input Phase Single-Phase
Maximum Input Amps 16
Nominal Input Voltage(s) Supported 120V AC
Rated input current (Maximum Load) 16.0A
Recommended Electrical Service 20A 120V
UPS Input Connection Type 5-20P
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3.1
Output
Frequency Compatibility 50 / 60 Hz
Individually Controllable Load Banks Yes
Load Management Receptacles Two switched single outlet load banks (2x 5-20R and 2x 5-20R )
Nominal Output Voltage(s) Supported 100V; 110V; 120V; 125V
Nominal Voltage Details 120v nominal output in battery mode
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Output Capacity (kVA) 1.95
Output Capacity (kW) 1.95
Output Capacity (VA) 1950
Output Capacity (Watts) 1950
Output Receptacles (6) 5-20R; (1) L5-20R
Output Voltage Regulation (Battery Mode) -10% +6%
Output Voltage Regulation (Line Mode) 120V (-13% +15%)
Power Factor 1
Physical
Cooling Method Fan
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount; Tower
Minimum Required Rack Depth (cm) 68.58
Minimum Required Rack Depth (inches) 27
Minimum Required Rack Depth with External Battery Pack (cm) 67
Minimum Required Rack Depth with External Battery Pack (in.) 26.5
Minimum Required Rack Depth without External Battery Pack (cm) 69
Minimum Required Rack Depth without External Battery Pack (in.) 27
Mounting Details Included mounting bracket enables installation in 4 post racks. Two ABS mounting stands enables the UPS to be configured in an upright tower orientation.
Primary Form Factor Rackmount; Tower
Primary UPS Depth (mm) 602
Primary UPS Height (mm) 86
Primary UPS Width (mm) 437
Shipping Dimensions (hwd / cm) 23.88 x 57.91 x 78.49
Shipping Dimensions (hwd / in.) 9.40 x 22.80 x 30.90
Unit Dimensions (hwd / in.) 3.400 x 17.000 x 23.700
Unit Weight (kg) 29.62
Unit Weight (lbs.) 65.3
UPS Housing Material Steel
UPS Power Module Dimensions (hwd cm) 8.64 x 43.69 x 60.20
UPS Power Module Dimensions (hwd in.) 3.4 x 17.2 x 23.7
Rack Height 2U
Shipping Weight (kg) 35.61
Shipping Weight (lbs.) 78.50
Warranty
Warranty/Returns 30 Days