Tripp Lite SMART2200NET SmartPro 120V 2.2kVA 1.7kW Line-Interactive UPS Tower Extended run 3 DB9 ports UPS Battery Backup

Tripp Lite SMART2200NET SmartPro 120V 2.2kVA 1.7kW Line-Interactive UPS Tower Extended run 3 DB9 ports

$1,153.16
Manufacturer:Eaton / Tripp Lite
Model:SMART2200NET
Condition:New
Availability:In Stock
The Tripp Lite SMART2200NET 2200VA UPS safeguards servers and critical equipment with battery backup surge protection and AVR. Provides reliable power during outages and voltage fluctuations.
Datasheet

The Tripp Lite SMART2200NET 2200VA Smart AVR Tower UPS provides comprehensive power protection for servers workstations and network devices. With a 2200VA/1700W capacity it offers extended runtime during power outages allowing for safe system shutdowns and data preservation. The integrated automatic voltage regulation (AVR) corrects minor voltage fluctuations without switching to battery conserving battery life.

This tower UPS features a DB9 serial port for seamless communication and monitoring. Its intelligent design provides advanced features such as surge suppression overload protection and EMI/RFI filtering ensuring the connected equipment receives clean and stable power. The SMART2200NET offers reliable performance and peace of mind for protecting critical systems in various environments.

APPLICATIONS
UPS Applications Large Network
COMMUNICATIONS
Communications Cable 3 DB9 cables included
Communications Interface Contact closure; DB9 Serial
Network Management Card Description Network management not supported
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions; contact closure communications via two additional DB9 ports (3 total)
PowerAlert Software For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number SMART2200NET
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Surge/noise protection
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 140
Low Voltage Transfer to Battery Power (Setpoint) 87
Transfer Time 2-4 milliseconds
OVERVIEW
UPC Code 037332032041
UPS Type Line-Interactive
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); NOM (Mexico); UL 1778
Product Compliance RoHS; FCC Part 15 Class A (USA)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 720
AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
USER INTERFACE ALERTS & CONTROLS
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced alarm will re-sound to indicate low-battery status
Audible Alarm Audible alarm indicates power-failure and low-battery conditions
LED Indicators 5 LEDs indicate line power battery power overload voltage regulation and battery low/replace status
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; set of 4 rear-panel switches control system enable and contact closure port inverter shutoff commands
VOLTAGE REGULATION
Overvoltage Correction Input voltages between 127 and 140 are reduced by 12%
Severe Undervoltage Correction Input voltages between 87 and 94 are boosted by 22%
Undervoltage Correction Input voltages between 95 and 105 are boosted by 10%
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 87 to 140
Battery
Battery Recharge Rate (Included Batteries) Less than 9 hours from 10% to 90% (typical full load discharge)
DC System Voltage (VDC) 24
Expandable Runtime Yes
Runtime Full Load (min.) 11 min. (1700W)
Runtime Half Load (min.) 27 min. (850W)
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Mode BTU / Hr. (Full Load) 59
AC Mode Efficiency Rating (100% Load) 99%
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load 867
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 0-95% non-condensing
Storage Temperature Range 5 to 122F (-15 to 50C)
Input
Input Circuit Breakers 20A
Input Cord Length (ft.) 8
Input Cord Length (m) 2.44
Input Phase Single-Phase
Maximum Input Amps 15
Nominal Input Voltage(s) Supported 120V AC
Rated input current (Maximum Load) 15A
Recommended Electrical Service 20A 120V
UPS Input Connection Type 5-15P
UPS Input Cord Length (ft.) 8
UPS Input Cord Length (m) 2.4
Output
Frequency Compatibility 60 Hz
Individually Controllable Load Banks Yes
Load Management Receptacles Two switchable single outlet 5-15R load banks
Nominal Output Voltage(s) Supported 110V; 115V; 120V
Nominal Voltage Details 120v nominal output in battery mode
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
Output Capacity (kVA) 2.2
Output Capacity (kW) 1.7
Output Capacity (VA) 2200
Output Capacity (Watts) 1700
Output Capacity Details Output is reduced to 1200W maximum with 1-2 external battery packs and 800W maximum with 3 or more external battery packs
Output Receptacles (6) 5-15R
Output Voltage Regulation (Battery Mode) +/- 5%
Output Voltage Regulation (Line Mode) -13% / +5%
Power Factor 0.8
Physical
Primary Form Factor Tower
Primary UPS Depth (mm) 318
Primary UPS Height (mm) 432
Primary UPS Width (mm) 229
Shipping Dimensions (hwd / cm) 34.92 x 41.91 x 57.15
Shipping Dimensions (hwd / in.) 13.75 x 16.50 x 22.50
Unit Dimensions (hwd / in.) 17.000 x 9.000 x 12.500
Unit Weight (kg) 36.29
Unit Weight (lbs.) 80.0000
UPS Housing Material Polycarbonate
UPS Power Module Dimensions (hwd cm) 43.18 x 22.86 x 31.75
UPS Power Module Dimensions (hwd in.) 17 x 9 x 12.5
UPS Power Module Weight (kg) 36.29
UPS Power Module Weight (lbs.) 80
Rack Height 0U
Shipping Weight (kg) 37.27
Shipping Weight (lbs.) 82.16
Warranty
Warranty/Returns 30 Days