Tripp Lite SMART1548ET 120VAC 48VDC 2000VA 1600W Extreme Temperature Network UPS for Industrial and Traffic Networks 3U Hardwire TAA UPS Battery Backup

Tripp Lite SMART1548ET 120VAC 48VDC 2000VA 1600W Extreme Temperature Network UPS for Industrial and Traffic Networks 3U Hardwire TAA

$1,370.22
Manufacturer:Eaton / Tripp Lite
Model:SMART1548ET
Condition:New
Availability:In Stock
The Tripp Lite SMART1548ET 1500VA 48V UPS protects critical equipment in harsh environments. This 3U rackmount UPS provides 1200W ideal for industrial and traffic networks with network card and dry-contact options.
Datasheet

The Tripp Lite SMART1548ET Extreme Temperature UPS System provides reliable 1500VA/1200W battery backup and surge protection for connected equipment in industrial and traffic network applications. Its 48V DC output makes it uniquely suitable for powering devices with specific voltage requirements. Designed for 3U rackmount installation the SMART1548ET features a network card slot for remote monitoring and management as well as dry-contact ports for integration with other systems.

With its extreme temperature tolerance the SMART1548ET ensures consistent performance in challenging environments. The hardwire input connection allows for secure and permanent power supply integration. This UPS is an ideal solution for maintaining uptime and protecting valuable equipment in demanding industrial and traffic network infrastructures.

APPLICATIONS
UPS Applications Mission Critical Applications; Extreme Temperature Applications
COMMUNICATIONS
Communications Interface DB9 Serial; Slot for SNMP/Web interface; USB
Input Dry Contact Ports 1 set of input dry contacts generate an alarm of configurable input conditions when pins 1&2 are shorted; Rating: 300VDC/12A; Wiring Gauge: Up to 12AWG
Network Management Card Description Network management card optional
Network Monitoring Port Description WEBCARDLXMINI network management card option supports operation from 0C to 70C as measured inside the UPS; Built-in USB and Serial ports support UPS configuration via Windows Hyperterminal session
Output Dry Contact Ports 6 sets of output dry contacts support normally-open or normally-closed signaling of configurable UPS conditions; Rating: 300VDC/12A; Wiring Gauge: Up to 12AWG
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number SMART1548ET
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Yes
Grounding Details Grounding lug connector provides a permanent ground connection for the UPS
High Availability UPS Features Automatic Voltage Regulation (AVR); Surge/noise protection; Extreme Operating Temperature
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 152V (default adjustable from 120 to 152V)
Low Voltage Transfer to Battery Power (Setpoint) 88V (default adjustable from 88 to 120V)
Transfer Time UPS mode: 10ms (typical) / 12ms (max); Generator mode: 20ms (typical) / 22ms (max)
OVERVIEW
UPC Code 037332241207
UPS Type Line-Interactive
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); NOM (Mexico); UL 1778
Product Compliance RoHS; Trade Agreements Act (TAA)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 474
EMI / RFI AC Noise Suppression Yes
USER INTERFACE ALERTS & CONTROLS
Audible Alarm Audible alarm reports Battery mode operation Battery low status Overload and UPS Fault conditions
Front Panel LCD Display Four line text-based front panel LCD provides full access to UPS status alarms faults events settings and control options
LED Indicators Set of 3 front panel LEDs report AC output status (green) Alarm condition (yellow) and Fault condition (red)
Switches All three front-panel circuit breakers serve as power switches required to energize the UPS (DC INPUT AC INPUT AC OUTPUT); Three additional switches below the LCD provide SCROLL ESCAPE and ENTER functions
VOLTAGE REGULATION
Overvoltage Correction Overvoltages from 128 to 152V are reduced by 20% (default adjustable from 120 to 144V)
Undervoltage Correction Undervoltages from 88 to 102V are boosted by 8% (default adjustable from 88 to 120V)
Voltage Regulation Description Corrects brownouts and overvoltages from 88 to 152V to 120V nominal (factory default)
Battery
Battery Charge Temperature compensated 2/4/6/8/10A selectable charging system; Battery temperature sensor cable included
DC System Voltage (VDC) 48V DC
Expandable Runtime Yes
LVC (Low Voltage Cut-Off) UPS automatically shuts off in battery mode as battery system voltage drops to 42.5V
Runtime Full Load (min.) 117 min. (1600W)
Runtime Half Load (min.) 269 min. (800W)
Typical Battery Runtime Above runtimes of full-load (2000VA/1600W) and half-load (1000VA/800W) with use of 48VDC 100AH battery system within a -40F(-40C)-to-131F (55C) operating environment. See manual and runtime charts for expanded runtimes with 55AH 100AH 110AH and 200AH battery configurations based on supported load and temperature
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Mode BTU / Hr. (Full Load) 266
AC Mode Efficiency Rating (100% Load) >95%
Audible Noise 52.4 dB maximum front-side 1 meter
Operating Temperature Range -40 to 176F (-40 to 80C)
Relative Humidity Up to 95% non-condensing
Storage Temperature Range -40 to 176F (-40 to 80C)
Operating Elevation 0-3280 ft. (0-1000 m)
Input
Input Circuit Breakers 30A breaker
Input Phase Single-Phase
Maximum Input Amps 22
Nominal Input Voltage(s) Supported 120V AC
Rated input current (Maximum Load) 22A
Recommended Electrical Service 120V AC
UPS Input Connection Description Protected Line Neutral and Ground hardwire input terminals; Includes strain relief
UPS Input Connection Type Hardwire
Output
Frequency Compatibility 50 / 60 Hz
Individually Controllable Load Banks No
Nominal Output Voltage(s) Supported 120V
Output AC Waveform (AC Mode) Pure Sine Wave
Output AC Waveform (Battery Mode) Pure Sine wave
Output Capacity (kVA) 2
Output Capacity (kW) 1.6
Output Capacity (VA) 2000
Output Capacity (Watts) 1600
Output Capacity Details Maximum output capacity is temperature dependent: 1600W (-40 to 55 C) / 1200W (55 to 75 C) and 1000W (75 to 80 C)
Output Circuit Breakers 30A breaker
Output Receptacle Details Protected Line Neutral and Ground hardwire output terminals; Includes strain relief
Output Receptacles Hardwire
Output Voltage Regulation (Battery Mode) 120V (4%)
Output Voltage Regulation (Line Mode) 120V (-14% / +8%) Factory setting adjustable
Power Factor 0.8
Physical
Cooling Method High speed user-replaceable fan with dust filter
Installation Form Factors Supported with Included Accessories 2 post 19 inch rackmount; 4 post 19 inch rackmount
Maximum Device Depth (cm) 24.00
Maximum Device Depth (in.) 9.450
Maximum Device Depth (mm) 240
Minimum Required Rack Depth (cm) 25.40
Minimum Required Rack Depth (inches) 10
Mounting Details Set of two rackmount brackets support installation in 2 or 4 post racks
Primary Form Factor Rackmount
Primary UPS Depth (mm) 240
Primary UPS Height (mm) 133
Primary UPS Width (mm) 400
Shipping Dimensions (hwd / in.) 9.60 x 15.30 x 23.10
Unit Dimensions (hwd / in.) 5.240 x 15.750 x 9.450
Unit Weight (kg) 14.70
Unit Weight (lbs.) 32.410
UPS Housing Material Steel
UPS Power Module Dimensions (hwd in.) 5.24 x 15.750 x 9.45
UPS Power Module Weight (kg) 14.70
UPS Power Module Weight (lbs.) 32.41
Rack Height 3U
Shipping Weight (kg) 15.74
Warranty
Warranty/Returns 30 Days