Tripp Lite SMART1500TSU 1440VA 1200W Line-Interactive UPS - 8 NEMA 5-15R Outlets AVR 120V 50/60 Hz USB LCD Tower
$340.12
Manufacturer:Eaton / Tripp Lite
Model:SMART1500TSU
Condition:New
Availability:In Stock
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SMART Series
- UPS Battery Backup
- Search
- Tripp Lite SMART1500TSU 1440VA 1200W Line-Interactive UPS - 8 NEMA 5-15R Outlets AVR 120V 50/60 Hz USB LCD Tower
Datasheet
The Tripp Lite SMART1500TSU 1440VA/1200W Line-Interactive UPS safeguards your sensitive equipment from power disruptions. With eight NEMA 5-15R outlets automatic voltage regulation (AVR) and a user-friendly LCD this tower UPS offers comprehensive protection.
Ideal for desktops workstations and home networks it provides ample runtime during outages allowing you to save data and safely shut down your devices. The USB port enables convenient monitoring and management of the UPS through your computer.
| APPLICATIONS | |
| UPS Applications | Home/Office Desktop; Audio/Video; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality |
| COMMUNICATIONS | |
| Communications Cable | USB and Serial interface cables included |
| Communications Interface | DB9 Serial; USB (HID enabled) |
| Network Management Card Description | Network management not supported |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| WatchDog Compatibility | Supports Watchdog application OS and hard-reboot restart options for remote applications |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SMART1500TSU |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS |
| High Availability UPS Features | Automatic Voltage Regulation (AVR); Surge/noise protection |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 145 |
| Low Voltage Transfer to Battery Power (Setpoint) | 89 |
| Transfer Time | 6 milliseconds typical (10 milliseconds max) |
| OVERVIEW | |
| UPC Code | 037332214249 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | RETIE (Colombia); CSA (Canada); UL 1778 |
| Product Compliance | RoHS; FCC Part 15 Class A (USA) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 316 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| UPS Dataline Suppression | 1 line TEL/DSL or Ethernet |
| USER INTERFACE ALERTS & CONTROLS | |
| Audible Alarm | UPS remains silent in battery backup mode; Alarm sounds only to report low-battery fault overload and replace-battery conditions |
| Front Panel LCD Display | Touchscreen LCD reports input voltage output voltage load percentage battery charge percentage and overload status |
| Switches | Power off/on switch |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Input voltages between 128 and 149 are reduced by 15% |
| Undervoltage Correction | Input voltages between 89 and 108 are boosted by 18% |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 89 to 145 |
| Battery | |
| Battery Access | Battery access door |
| Battery Recharge Rate (Included Batteries) | 8 hours (10% to 90%) |
| Battery Replacement Description | Replaceable internal batteries (see manual) |
| DC System Voltage (VDC) | 12 |
| Expandable Runtime | No |
| Runtime Full Load (min.) | 1.5 min. (1200W) |
| Runtime Half Load (min.) | 6 min. (600W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 175 |
| AC Mode Efficiency Rating (100% Load) | >95% |
| Audible Noise | Less than 50db (front side 1m) |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-90% non-condensing |
| Storage Temperature Range | 5 to 113F (-15 to 45C ) |
| Operating Elevation | 0-10000 ft. (0-3000 m) |
| Input | |
| Input Circuit Breakers | 15A |
| Input Phase | Single-Phase |
| Maximum Input Amps | 12 |
| Nominal Input Voltage(s) Supported | 120V AC |
| Rated input current (Maximum Load) | 12A |
| Recommended Electrical Service | 15A 120V |
| UPS Input Connection Type | 5-15P |
| UPS Input Cord Length (ft.) | 5 |
| UPS Input Cord Length (m) | 1.5 |
| Output | |
| Frequency Compatibility | 50 / 60 Hz |
| Hot-Swap PDU options | PDUB15 (2U / 8 5-15R outlets) |
| Individually Controllable Load Banks | No |
| Nominal Output Voltage(s) Supported | 110V; 115V; 120V |
| Nominal Voltage Details | 120v nominal output in battery mode |
| Output AC Waveform (AC Mode) | Pure sine wave |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Output Capacity (kVA) | 1.44 |
| Output Capacity (kW) | 1.2 |
| Output Capacity (VA) | 1440 |
| Output Capacity (Watts) | 1200 |
| Output Receptacles | (8) 5-15R |
| Output Voltage Regulation (Battery Mode) | 120V (10%) |
| Output Voltage Regulation (Line Mode) | 120V (+6%/-12%) |
| Power Factor | 0.83 |
| UPS Output Receptacles (Surge Suppression Only) | 6 UPS outlets 2 surge-only outlets |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | Tower |
| Primary Form Factor | Desktop |
| Primary UPS Depth (mm) | 381 |
| Primary UPS Height (mm) | 191 |
| Primary UPS Width (mm) | 140 |
| Shipping Dimensions (hwd / in.) | 11.70 x 9.30 x 19.50 |
| Unit Weight (kg) | 14.61 |
| Unit Weight (lbs.) | 32.200 |
| UPS Housing Material | ABS |
| UPS Power Module Dimensions (hwd in.) | 7.5 x 5.5 x 15 |
| UPS Power Module Weight (kg) | 14.61 |
| UPS Power Module Weight (lbs.) | 32.2 |
| Shipping Weight (kg) | 15.10 |
| Warranty | |
| Warranty/Returns | 30 Days |

