Tripp Lite SMART1500SLT SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS Tower Network Card Options USB DB9 8 Outlets UPS Battery Backup

Tripp Lite SMART1500SLT SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS Tower Network Card Options USB DB9 8 Outlets

$684.95
Manufacturer:Eaton / Tripp Lite
Model:SMART1500SLT
Condition:New
Availability:In Stock
The Tripp Lite SMART1500SLT 1500VA UPS safeguards servers and other vital equipment with AVR sine wave output USB DB9 and SNMP connectivity for network management.
Datasheet

The Tripp Lite SMART1500SLT 1500VA Smart UPS provides reliable battery backup and surge protection for connected equipment. Featuring automatic voltage regulation (AVR) it corrects brownouts and overvoltages without using battery power extending battery life. Its pure sine wave output ensures compatibility with sensitive electronics and active PFC power supplies.

This tower UPS offers USB and DB9 connectivity for local monitoring and control. Network management capabilities via SNMP allow remote monitoring and control making it ideal for server rooms and network closets. The SMART1500SLT delivers 900W of power offering ample runtime for critical systems during power outages.

APPLICATIONS
UPS Applications Large Network; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality
COMMUNICATIONS
Communications Cable USB and DB9 cabling included
Communications Interface DB9 Serial; Slot for SNMP/Web interface; USB (HID enabled)
Network Management Card Description Network management card optional
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert
WatchDog Compatibility Supports Watchdog application OS and hard-reboot restart options for remote applications
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number SMART1500SLT
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS
High Availability UPS Features Auto Probe Monitoring (requires WEBCARDLXE); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 145V (120V) 133V (110V) 121V (100V); All voltage setpoints 5% tolerance
Low Voltage Transfer to Battery Power (Setpoint) 95V (120V) 87V (110V) 83V (100V); All voltage setpoints 5% tolerance
Transfer Time 4-6 milliseconds
OVERVIEW
UPC Code 037332119896
UPS Type Line-Interactive
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); NOM (Mexico); UL 1778
Product Compliance RoHS; FCC Part 15 Class A (USA)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 690
AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
UPS Dataline Suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
USER INTERFACE ALERTS & CONTROLS
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm Audible alarm indicates power failure and overload conditions
LED Indicators Status LEDs indicate line power battery power AVR overload and replace battery status - with a 3-LED level meter for load and battery charge level
Site Wiring Fault Indication Rear panel site wiring fault LED
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection
VOLTAGE REGULATION
Overvoltage Correction Voltage reduction of 12% applies when input is 127 to 145 (120v) 116 to 133 (110v) 111 to 121 (100v); All voltage setpoints 5% tolerance
Undervoltage Correction Voltage boost of 14% applies when input is 95 to 108 (120v) 87 to 99 (110v) 83 to 90 (100v); All voltage setpoints5% tolerance
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 95 to 145 (120v) 87 to 133 (110v) 83 to 121 (100v)
Battery
Battery Access Battery access door
Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 80% (typical full load discharge)
Battery Replacement Description Hot-swappable user replaceable batteries
DC System Voltage (VDC) 36
Expandable Runtime No
Runtime Full Load (min.) 8 min. (900W)
Runtime Half Load (min.) 20 min. (450W)
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Mode BTU / Hr. (Full Load) 148
AC Mode Efficiency Rating (100% Load) 95%
Audible Noise Audible Noise < 50 dBA at Front Side 1 Meter
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load 500
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 0-95% non-condensing
Storage Temperature Range 5 to 122F (-15 to 50C)
Operating Elevation 0-6562 ft. (0-2000 m)
Input
Input Circuit Breakers 15A
Input Phase Single-Phase
Maximum Input Amps 10
Nominal Input Voltage(s) Supported 100V AC; 110V AC; 120V AC
Rated input current (Maximum Load) 10.1A (100V) 9.3A (110V) 8.6A (120V)
Recommended Electrical Service 15A 120V
Total Harmonic Distortion 0.03
UPS Input Connection Type 5-15P
UPS Input Cord Length (ft.) 6
UPS Input Cord Length (m) 1.8
Output
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection. Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.
Individually Controllable Load Banks No
Nominal Output Voltage(s) Supported 100V; 110V; 120V
Nominal Voltage Details 120V sinusoidal in line mode and 120V sinusoidal in battery mode
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Output Capacity (kVA) 1.5
Output Capacity (kW) 0.9
Output Capacity (VA) 1500
Output Capacity (Watts) 900
Output Capacity Details 7.5A @ 120V (default) 8.2A @ 110V 9A @ 100V. 125% @ 10 minutes 110% +/- 10% @ 5 seconds
Output Receptacles (8) 5-15R
Output Voltage Regulation (Battery Mode) +/- 5%
Output Voltage Regulation (Line Mode) -13% + 15%
Power Factor 0.63
Physical
Cooling Method Fan
Installation Form Factors Supported with Included Accessories Tower
Primary Form Factor Tower
Primary UPS Depth (mm) 335
Primary UPS Height (mm) 259
Primary UPS Width (mm) 173
Shipping Dimensions (hwd / cm) 35.31 x 24.64 x 44.70
Shipping Dimensions (hwd / in.) 13.90 x 9.70 x 17.60
Unit Dimensions (hwd / in.) 10.250 x 6.750 x 13.250
Unit Weight (kg) 20.41
Unit Weight (lbs.) 45.0000
UPS Housing Material Steel
UPS Power Module Dimensions (hwd cm) 25.91 x 17.27 x 33.53
UPS Power Module Dimensions (hwd in.) 10.2 x 6.8 x 13.2
UPS Power Module Weight (kg) 20.41
UPS Power Module Weight (lbs.) 45
Shipping Weight (kg) 21.00
Shipping Weight (lbs.) 46.30
Warranty
Warranty/Returns 30 Days