Tripp Lite SM3000RMXL2UTAA TAA SmartPro 120V 3kVA 2.88kW Line-Interactive Sine Wave UPS 2U Extended Run Network Card Options LCD USB DB9
$1,645.44
Manufacturer:Eaton / Tripp Lite
Model:SM3000RMXL2UTAA
Condition:New
Availability:In Stock
Condition:New
Availability:In Stock
- Power Protection
- Eaton / Tripp Lite
- UPS System
- SmartPro SM Series
- UPS Battery Backup
- Search
- Tripp Lite SM3000RMXL2UTAA TAA SmartPro 120V 3kVA 2.88kW Line-Interactive Sine Wave UPS 2U Extended Run Network Card Options LCD USB DB9
Datasheet
The Tripp Lite Smart3000RMXL2UTAA 3000VA/2880W UPS system provides reliable battery backup and surge protection for critical server network and telecom equipment. This intelligent rackmount UPS features automatic voltage regulation (AVR) to correct brownouts and overvoltages without consuming battery power extending runtime for when it's needed most. Its 2U form factor conserves valuable rack space.
With USB and DB9 connectivity the Smart3000RMXL2UTAA offers comprehensive monitoring and control options. TAA compliance ensures it meets government procurement requirements. Protect your valuable equipment with the robust power protection of this Tripp Lite UPS.
| APPLICATIONS | |
| UPS Applications | Large Network |
| COMMUNICATIONS | |
| Communications Cable | USB DB9 and EPO cabling included |
| Communications Interface | DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
| Network Management Card Description | Network management card optional |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
| DETAIILS | |
| Manufacturer | Tripp Lite |
| Manufacturer Part Number | SM3000RMXL2UTAA |
| FEATURES & SPECIFICATIONS | |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
| High Availability UPS Features | Automatic Voltage Regulation (AVR); Hot swappable batteries; Pure sine wave output; Remote management; Surge/noise protection; Auto Probe Monitoring (requires WEBCARDLXE) |
| LINE / BATTERY TRANSFER | |
| High Voltage Transfer to Battery Power (Setpoint) | 145 |
| Low Voltage Transfer to Battery Power (Setpoint) | 83 |
| Transfer Time | 5 milliseconds (AC to battery mode) 1 millisecond (Battery to AC mode) |
| OVERVIEW | |
| UPC Code | 037332153609 |
| UPS Type | Line-Interactive |
| STANDARDS & COMPLIANCE | |
| Product Certifications | CSA (Canada); UL 1778 |
| Product Compliance | RoHS; FCC Part 15 Class A (USA); Trade Agreements Act (TAA) |
| SURGE / NOISE SUPPRESSION | |
| AC Suppression Joule Rating | 570 |
| AC Suppression Response Time | Instantaneous |
| EMI / RFI AC Noise Suppression | Yes |
| USER INTERFACE ALERTS & CONTROLS | |
| Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
| Audible Alarm | Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions |
| Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
| Switches | 3 pushbutton switches control OFF / ON power status MODE selection and MUTE / ENTER control functions |
| VOLTAGE REGULATION | |
| Overvoltage Correction | Input voltages between 127 and 145 are reduced by 12% |
| Severe Undervoltage Correction | Input voltages between 83 and 95 are boosted by 24% |
| Undervoltage Correction | Input voltages between 108 and 96 are boosted by 12% |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145 |
| Battery | |
| Battery Access | Front panel battery access door |
| Battery Recharge Rate (Included Batteries) | Less than 5 hours from 10 to 90% |
| Battery Replacement Description | Hot-swappable replaceable batteries |
| DC System Voltage (VDC) | 48 |
| Expandable Runtime | Yes |
| Runtime Full Load (min.) | 3 min. (2880W) |
| Runtime Half Load (min.) | 10 min. (1440W) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Details | |
| Category | UPS System |
| Environmental | |
| AC Mode BTU / Hr. (Full Load) | 409 |
| Audible Noise | 45 dBA maximum front side 1m |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 1736 |
| Operating Temperature Range | 32 to 104F (0 to 40C) |
| Relative Humidity | 0-95% non-condensing |
| Storage Temperature Range | 5 to 122F (-15 to 50C) |
| Input | |
| Input Phase | Single-Phase |
| Maximum Input Amps | 24 |
| Nominal Input Voltage(s) Supported | 120V AC |
| Rated input current (Maximum Load) | 24A |
| Recommended Electrical Service | 30A 120V |
| UPS Input Connection Type | L5-30P |
| UPS Input Cord Length (ft.) | 10 |
| UPS Input Cord Length (m) | 3.1 |
| Output | |
| Frequency Compatibility | 60 Hz |
| Individually Controllable Load Banks | Yes |
| Load Management Receptacles | Two switchable single outlet 5-15/20R load banks |
| Nominal Output Voltage(s) Supported | 110V; 115V; 120V |
| Nominal Voltage Details | 120v nominal output in battery mode |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Output Capacity (kVA) | 3 |
| Output Capacity (kW) | 2.88 |
| Output Capacity (VA) | 3000 |
| Output Capacity (Watts) | 2880 |
| Output Circuit Breakers | Two 20A output breakers protect 4 5-15/20R outlets each |
| Output Receptacles | (8) 5-15/20R; (1) L5-30R |
| Output Voltage Regulation (Battery Mode) | +/-5% |
| Output Voltage Regulation (Line Mode) | +6% -14% |
| Power Factor | .96 |
| Physical | |
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount |
| Minimum Required Rack Depth (cm) | 55.88 |
| Minimum Required Rack Depth (inches) | 22 |
| Minimum Required Rack Depth with External Battery Pack (cm) | 67 |
| Minimum Required Rack Depth with External Battery Pack (in.) | 26.5 |
| Minimum Required Rack Depth without External Battery Pack (cm) | 64 |
| Minimum Required Rack Depth without External Battery Pack (in.) | 25 |
| Mounting Details | Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm) |
| Primary Form Factor | Rackmount |
| Primary UPS Depth (mm) | 483 |
| Primary UPS Height (mm) | 89 |
| Primary UPS Width (mm) | 445 |
| Shipping Dimensions (hwd / cm) | 22.10 x 61.21 x 55.88 |
| Shipping Dimensions (hwd / in.) | 8.70 x 24.10 x 22.00 |
| Unit Dimensions (hwd / in.) | 3.500 x 17.500 x 19.000 |
| Unit Weight (kg) | 29.03 |
| Unit Weight (lbs.) | 64.000 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd cm) | 8.89 x 44.45 x 48.26 |
| UPS Power Module Dimensions (hwd in.) | 3.50 x 17.50 x 19.00 |
| UPS Power Module Weight (kg) | 29.03 |
| UPS Power Module Weight (lbs.) | 64 |
| Rack Height | 2U |
| Shipping Weight (kg) | 40.82 |
| Shipping Weight (lbs.) | 90.00 |
| Warranty | |