Tripp Lite SM1500RMXL2UTAA 2U UPS Replacement 36VDC Battery Cartridge (1 Set of 3) for Select SmartPro UPS UPS Replacement Batteries

Tripp Lite SM1500RMXL2UTAA 2U UPS Replacement 36VDC Battery Cartridge (1 Set of 3) for Select SmartPro UPS

$988.25
Manufacturer:Eaton / Tripp Lite
Model:SM1500RMXL2UTAA
Condition:New
Availability:In Stock
The Tripp Lite SM1500RMXL2UTAA is a 1500VA/1350W 2U rackmount UPS with AVR providing reliable battery backup and surge protection for critical equipment. TAA compliant.
Datasheet

The Tripp Lite SM1500RMXL2UTAA SmartOnline 1500VA/1350W UPS System offers double-conversion backup power surge suppression and voltage regulation in a compact 2U rack/tower form factor. Ideal for protecting servers networking equipment and other sensitive electronics it ensures continuous operation during power failures while safeguarding against damaging surges and voltage fluctuations. It features USB and DB9 connectivity for monitoring and control.

This TAA-compliant UPS provides automatic voltage regulation (AVR) to correct minor power fluctuations without switching to battery power extending battery life. The SM1500RMXL2UTAA is a reliable solution for maintaining business continuity and protecting valuable equipment in demanding IT environments.

APPLICATIONS
UPS Applications Large Network; High-End Desktop/Small Network
COMMUNICATIONS
Communications Cable USB and DB9 cabling included
Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
Network Management Card Description Network management card optional
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
Network UPS Tools (NUT) Compatibility NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
PowerAlert Software For local monitoring via the UPSs built-in communication ports download PowerAlert software at https://tripplite.eaton.com/products/power-alert
WatchDog Compatibility Supports Watchdog application OS and hard-reboot restart options for remote applications
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number SM1500RMXL2UTAA
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
Grounding Details Back panel grounding lug
High Availability UPS Features Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection
LINE / BATTERY TRANSFER
High Voltage Transfer to Battery Power (Setpoint) 145
Low Voltage Transfer to Battery Power (Setpoint) 83
Transfer Time 4 milliseconds (AC to battery mode) 1 millisecond (Battery to AC mode)
OVERVIEW
UPC Code 037332152831
UPS Type Line-Interactive
STANDARDS & COMPLIANCE
Product Certifications CSA (Canada); UL 1778
Product Compliance RoHS; FCC Part 15 Class B (USA); Trade Agreements Act (TAA)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 570
AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
USER INTERFACE ALERTS & CONTROLS
Alarm Cancel Operation Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Audible Alarm Audible alarm indicates UPS startup power-failure low-battery overload UPS fault and remote shutdown conditions
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
Switches 3 pushbutton switches control OFF / ON power status MODE selection and MUTE / ENTER control functions
VOLTAGE REGULATION
Overvoltage Correction Input voltages between 127 and 145 are reduced by 12%
Severe Undervoltage Correction Input voltages between 83 and 94 are boosted by 24%
Undervoltage Correction Input voltages between 95 and 108 are boosted by 12%
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
Battery
Battery Access Front panel battery access door
Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90%
Battery Replacement Description Hot-swappable user replaceable batteries
DC System Voltage (VDC) 36
Expandable Runtime Yes
Runtime Full Load (min.) 4.9 min. (1350W)
Runtime Half Load (min.) 14 min. (675W)
Battery Type Valve Regulated Lead Acid (VRLA)
Details
Category UPS System
Environmental
AC Mode BTU / Hr. (Full Load) 237
AC Mode Efficiency Rating (100% Load) 95%
Audible Noise 45 dBA maximum front side 1m
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load 751
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 0-95% non-condensing
Storage Temperature Range 5 to 122F (-15 to 50C)
Input
Input Circuit Breakers 15A
Input Phase Single-Phase
Maximum Input Amps 12
Nominal Input Voltage(s) Supported 120V AC
Rated input current (Maximum Load) 12A
Recommended Electrical Service 15A 120V
UPS Input Connection Type 5-15P
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3.1
Output
Frequency Compatibility 60 Hz
Individually Controllable Load Banks Yes
Load Management Receptacles Two switchable two-outlet 5-15R load banks
Nominal Output Voltage(s) Supported 110V; 115V; 120V
Nominal Voltage Details 120v nominal output in battery mode
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Output Capacity (kVA) 1.5
Output Capacity (kW) 1.35
Output Capacity (VA) 1500
Output Capacity (Watts) 1350
Output Capacity Details Output is reduced to 1200 watts maximum when used with external battery packs
Output Receptacles (8) 5-15R
Output Voltage Regulation (Battery Mode) +/- 5%
Output Voltage Regulation (Line Mode) -14% +6%
Power Factor 0.9
Physical
Cooling Method Fan
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Minimum Required Rack Depth (cm) 43.18
Minimum Required Rack Depth (inches) 17
Minimum Required Rack Depth with External Battery Pack (cm) 51
Minimum Required Rack Depth with External Battery Pack (in.) 20
Minimum Required Rack Depth without External Battery Pack (cm) 42
Minimum Required Rack Depth without External Battery Pack (in.) 16.5
Mounting Details Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Primary Form Factor Rackmount
Primary UPS Depth (mm) 342
Primary UPS Height (mm) 88
Primary UPS Width (mm) 439
Shipping Dimensions (hwd / cm) 22.35 x 58.42 x 49.02
Shipping Dimensions (hwd / in.) 8.80 x 23.00 x 19.30
Unit Weight (kg) 21.09
Unit Weight (lbs.) 46.5000
UPS Housing Material Steel
UPS Power Module Dimensions (hwd cm) 8.76 x 43.94 x 34.16
UPS Power Module Dimensions (hwd in.) 3.45 x 17.3 x 13.45
UPS Power Module Weight (kg) 21.09
UPS Power Module Weight (lbs.) 46.5
Rack Height 2U
Shipping Weight (kg) 26.04
Shipping Weight (lbs.) 57.40
Warranty
Warranty/Returns 30 Days