Tripp Lite PDUMVR20NETLX Eaton 1.9kW Single-Phase Switched PDU LX Platform Outlet Monitoring 120V Outlets (24 NEMA 5-15/20R) L5-20P Plug 0U TAA PDU Series

Tripp Lite PDUMVR20NETLX Eaton 1.9kW Single-Phase Switched PDU LX Platform Outlet Monitoring 120V Outlets (24 NEMA 5-15/20R) L5-20P Plug 0U TAA

$1,123.37
Manufacturer:Eaton / Tripp Lite
Model:PDUMVR20NETLX
Condition:New
Availability:In Stock
The Tripp Lite PDUMVR20NETLX provides 24 5-15/20R outlets outlet-level metering & LX Platform Interface for advanced control. 120V 1.9kW 0U vertical mount TAA compliant.
Datasheet

The Tripp Lite PDUMVR20NETLX is a 1.9kW single-phase switched PDU ideal for network closets and data centers. It features 24 5-15/20R outlets outlet-level metering and an LX Platform Interface for advanced monitoring and control. Includes an L5-20P/5-20P adapter and 10ft cord.

This 0U vertical-mount PDU offers convenient power distribution and remote management capabilities. The TAA compliance ensures it meets US federal government procurement requirements making it suitable for government and public sector applications.

COMMUNICATIONS
Communications Cable RJ45-to-DB9 configuration/console Access cable
Network Compatibility 10 Mbps; 100 Mbps (Fast Ethernet)
Network Monitoring Port RJ45 Network port RJ45 Serial Config/Console Access port; USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.
PowerAlert Software LX Platform Interface: PowerAlert Device Manager
SNMP Compatibility Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface telnet SSH and SNMP management systems
DETAIILS
Manufacturer Tripp Lite
Manufacturer Part Number PDUMVR20NETLX
FEATURES & SPECIFICATIONS
High Availability PDU Features Auto Probe Monitoring and Reboot (included); Auto Load Shedding
OVERVIEW
PDU Type Switched
UPC Code 037332204141
STANDARDS & COMPLIANCE
Product Certifications CAN/CSA-C22.2 No. 60950-1 (Canada); NOM (Mexico); UL 60950-1
Product Compliance RoHS; FCC Part 15 Class A (USA); Trade Agreements Act (TAA)
SURGE / NOISE SUPPRESSION
Automatic Shut-Off No
USER INTERFACE ALERTS & CONTROLS
Current Measurement Accuracy (Amps) +/-1%
Front Panel LCD Display Digital display reports load level in amps for LOAD BANK 1 (Outlets 1-12) LOAD BANK 2 (Outlets 13-24) LOAD BANKS 1&2 COMBINED (Outlets 1-24) and each individual output receptacle; Digital display can also be used to scroll the configured IP address
LED Indicators BANK 1 and BANK 2 LEDs verify which load bank the digital current display is reporting (Bank 1 Bank 2 or Banks 1&2 Combined); BANK 1 or BANK 2 LED will flash when the digital display is reporting output current for one of the outlets in that load bank; 24 additional LEDs one near each output receptacle will light continuously to verify power on/off status and flash to indicate that the digital display is reporting output current for just that individual receptacle. LX Platform Interface: Network Link/Activity Status LED (Yellow) Network Speed LED (Green); LX Platform status LED (Green)
Power Measurement Accuracy (Watts) +/-1%
Switches SELECT OUTLET and SELECT BANK switches advance the LCD screen and associated LED to display power consumption for individual output receptacles and output load banks; Press and hold the SELECT BANK button for 4 seconds to rotate the digital display 90 degrees for overhead power input; Press and hold the SELECT OUTLET button for 4 seconds to scroll the configured IP address. LX Platform Interface: Recessed reset switch for interface reboot and factory reset
Voltage Measurement Accuracy (Volts) +/-1%
Details
Category Power Distribution Units (PDUs)
Environmental
Operating Temperature Range 32 to 104F (0 to 40C)
Relative Humidity 5% to 95% non-condensing
Storage Temperature Range -22 to 140F (-30 to 60C)
Operating Elevation 0-10000 ft. (0-3000 m)
Input
Input Cord Length (ft.) 10
Input Cord Length (m) 3.05
Input Phase Single-Phase
Maximum Input Amps 16
Maximum Input Amps Details Agency de-rated to 16A continuous
PDU Input Voltage 120
PDU Plug Type NEMA 5-20P; NEMA L5-20P
Recommended Electrical Service Single-phase 20A 120V service
Output
Customized Load Management Receptacles Each outlet is individually controllable via remote interface
Frequency Compatibility 50 / 60 Hz
Output Capacity Details 1.92kW (120V) / 16A total capacity; 16A max per outlet
Output Nominal Voltage 120V
Output Receptacles (24) 5-15/20R
Physical
PDU Form Factor Vertical (0U)
Shipping Dimensions (hwd / cm) 11.51 x 15.49 x 192.48
Shipping Dimensions (hwd / in.) 4.53 x 6.10 x 75.78
Unit Dimensions (hwd / cm) 178 x 5.6 x 5.2
Unit Dimensions (hwd / in.) 70.000 x 2.200 x 2.050
Unit Weight (kg) 4.35
Unit Weight (lbs.) 9.6
Form Factors Supported 0U vertical rackmount; includes rackmount brackets. Supports toolless mounting in button-mount compatible racks
Material Of Construction Metal
Rack Height 0U
Shipping Weight (kg) 6.77
Shipping Weight (lbs.) 14.93
Warranty